PROBES

 

 

The DS60A operates with several different Prime magnetic probes including Models 
PM4, PM10, and PM15.  All probes are potted and completely sealed.  The probes do 
not respond to small amounts of fine metal filings, oil or dirt. 
 

Probe Model 

Min thickness  

Max thickness  

Probe Diameter 

PM4 

.04 mm (.0015”) 

.40 mm (.015”) 

18 mm (0.70”) 

PM10 

.10 mm (.004”) 

1.0 mm (.040”) 

30 mm (1.18”) 

PM15 

.15 mm (.006”) 

1.5 mm (.060”) 

36 mm (1.42”) 

 
 
INSTALLATION 
 

Installation of the individual components of the DS 60A system is covered in the 
following paragraphs: 
 

DS60A Control Module 

 
The control module is designed to mount with a simple bracket where convenient 
between the probe and a higher level controller such as a PLC.  Avoid mounting 
locations with excessive heat and vibration. 
 

Probes 

 
The probe must be mounted so that the sheet is in contact with the probe face as it 
passes.  The face of the probe is made of magnetic material and will last for many years 
of operation. 
 
The Model DS60A Double Sheet Detector can operate with no contact between the 
sheet material and the probe if the gap is kept very small and is held constant.  A 
constant gap is very important since a small change in gap causes significant change in 
the sensor signal.  If the system is to be operated with a gap between the probe and the 
sheet material, the unit must be calibrated after the gap is established.  If the gap is too 
large, the unit will not calibrate. 
 

Electrical Wiring 

 
The connection between the probe and the DS60A Controller requires a Prime Controls 
adapter cable model CBL110-X  where X indicates length.   
 
Power to the controller and the outputs from the controller connect through an industry 
standard male, four-pin “Micro” style connector.  For this connection use Prime Controls 
cable CBL104-3. 

Содержание DS60A

Страница 1: ...te wire on standard cable Pin 3 Common Blue wire on standard cable Pin 4 Sinking Output Black wire on standard cable When power is applied the green power indicator is solidly ON During normal sensing...

Страница 2: ...d so that the sheet is in contact with the probe face as it passes The face of the probe is made of magnetic material and will last for many years of operation The Model DS60A Double Sheet Detector ca...

Страница 3: ...re ON sourcing output high sinking output low the indicator is red and when the outputs are OFF the indicator is green In meter mode the indicator flashes at a rate proportional to the strength of the...

Страница 4: ...restart calibration 5 From gauge mode hold the pushbutton in for at least three seconds the controller enters meter mode 6 From meter mode tap the pushbutton once to exit meter mode CALIBRATION The D...

Страница 5: ...ial or double sample against the probe face 2 Tap the pushbutton twice in succession within 0 7 seconds The first sample is taken and the indicator flashes amber indefinitely at a 2 5 Hz rate 3 Place...

Страница 6: ...30V 2 1 4 3 50 mA 50 mA V COM SOURCE SINK CONTROLLER DIMENSIONS DS60 CONTROLLER HOUSING 15 85 0 625 51 0 2 00 12mm x 1mm THREAD 8 90 350 23 80 0 938 18 mm x 1 mm THREAD PWR OUT SET SENSOR RECEPTACLE P...

Страница 7: ...ctor Pin 4 Max applied voltage 30 Volts TVS limited Max current momentary 40 Amps Max current sustained 50 mA fuse limited Max off state leakage 30 V 25 uA Over current protection Self resetting 50 mA...

Страница 8: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE LIABILITY OF PRIME CONTROLS TO ANY PURCHASER SHALL BE L...

Отзывы: