IDLE CURRENT ADJUSTMENT
1:
Remove the jumper on P7 ( P6 )
2:
Connect the voltmeter between pin 1 and pin 2 on P7
( pin 1 and pin 2 on P6 )
ADJUST R154 ( R156 ) TO 30mV
3:
Connect the voltmeter between pin 3 and pin 4 on P7
( pin 3 and pin 4 on P6 )
ADJUST R153 ( R155 ) TO 30mV
4.
After the power has been on for 60 min
readjust R154 (R156) and R153 (R155)
6.
Remove the voltmeter and connect the jumper again.
Instructions apply to the left channel.
Instructions given in brackets apply to the
Right channel.