Before
attempting
the
connection
,
check
whether
the
voltage
indicated
on
the
rating
plate
corresponds
to
the
actual
mains
voltage
.
Mains
lead
should
be
minimum1
.
5m
long
.
Earth
wire
should
be
installed
in
such
manner
to
be
the
last
one
pulled
out
in
case
the
safety
device
of
the
mains
lead
should
fail
.
Mains
lead
behind
the
oven
must
be
placed
in
such a manner
to
avoid
touching
the
back
panel
of
the
oven
because
of
the
heat
it
develops
during
operation
.
Cable
correct
size
rating
please
oven
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220-240V
Caution! In the event of any connection the safety
Wire must be connected to the
E terminal.
Recommended
type of
connection
lead
1
For 220-240V earthed one-phase
connection, bridges connect 1-2-3
terminals and 4-5 terminals, safety
wire to
L
N
PE
H05VV-F3G4
L=R, N=earth terminal, PE=safety wire terminal
1
2
3
4
.
The connection cable must be secured in a strain
-
relief clamp.For the connection leads,
the earth wire must be longer than the other wires.
Caution
!
Remember to connect the safety circuit to the connection box terminal marked with
. The
electricity supply for the oven must have a
n
all
-
pole
disconnection
switch which enab
-
les
the
power
to
be
cut off in case of emergency. The distance between the working
contacts
of
the
safety
switch must be at least 3 mm.
Before connecting the oven to the power supply it is important to read the information on
the manual.
follow the below diagram.
10
11