fit I system connectors
connectors for horizontally oriented track
connectors for vertically oriented track
using support points in vertical connectors
M
FIT I system connectors are available in 2, 3 and 4 way versions. The example below demonstrates a three way connector for horizontally
oriented track. It is especially important to ensure that all track lengths are firmly attached to the connector. It is also important to ensure
that during the connector installation process, the track conductors were not push out the opposite side of the track length. This is explained in
detail in Part 1 of this instruction manual. Be sure to tighten all of the lock screws on the connector.
Tighten all of the lock screws
All track lengths are firmly attached
Track connector for horizontally oriented track
N
FIT I system connectors are available in 2, 3 and 4 way versions. The example below demonstrates a three way connector for vertically
oriented track. It is especially important to ensure that all track lengths are firmly attached to the connector. It is also important to ensure
that during the connector installation process, the track conductors were not pushws out the opposite side of the track length. This is explained in detail
in Part 1 of this instruction manual. Be sure to tighten all of the lock screws on the connector.
Tighten all of the lock screws
All track lengths are firmly attached
Track connector for vertically oriented track
Follow all local and national electrical codes.
For assistance please call Prima Customer Ser
vice at 562-407-3079
IMPORTANT Please read these instructions prior to installation. Refer to the Prima catalog for proper lamp type and maximum wattage for fixtures.
Prima is not responsible for any fixture or system failure caused by unsupported lamps. Contact Prima customer service for the latest updates on
which lamps we support and proper usage. Prima low voltage transformers must be used with all Prima Lighting product installations. All warranties
are void if Prima transformers are not used. Prima’s catalogs provide general information and suggestions for proper dimmer usage. Please consult
our customer service department with any questions regarding dimmer specifics. Prima is not responsible for any damage caused by improper
dimmer specification and usage. Use only qualified electrician for installation. Adhere to all local and national electrical codes prior to installation.
It is strongly recommended that gloves are used when handling the FIT I System track. Oils and dirt from fingers can sometimes permanently
mark the finish. Track should be cleaned with a damp cloth and thoroughly dried before fixture installation.Connectors are available for
extending track length, turning corners or creating intersections in the run. Great care must be taken to ensure the connector is installed
properly.
O
FIT I System connectors for vertically oriented track have the capability to accept cable or stem ceiling support point. By removing the axis
cap with a flat head screwdriver, a threaded hole is exposed at the center of the connector. Thread the track adapter portion of the
support point into this hole. Secure the support point to the connector by tightening the lower knob on the adapter.
Use a flat head screwdriver to remove the axis cap at the center of the connector
Thread the support point
into the hole at the
center of the connector
13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com
*Caution
*Caution:
Do not break the insulator inside
the chamber while using the
screw-in function. Broken insulator
will cause short of circuit.
This a
pplies to 2, 3, and 4 way connectors.
REV
.033015
prima fit I system
general installation instructions part 8 of 12