11
10
TIMER OFF
Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when
you want the unit to turn off automatically
after you go to bed. The air conditioner
will stop automatically at the set time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last
setting of stopping operation time and
the signal "h" will show on the display
area.
2. Press the TIMER OFF button to display
"10h" on the TIMER OFF display of
the remote controller.
3. Wait for about 3 seconds and the digital
display area will show the temperature
again. Now this function is activated.
TIMER OFF
Example:
h
TIMER ON OFF
h
On
Stop
2 hours later
after setting
Set
To stop the air conditioner 2 hours after
setting and start it again 10 hours after
setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to
display 2.0h on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to
display 10h on the TIMER ON display .
5. Wait for the remote control to display
the setting temperature.
TIMER OFF
TIMER ON
(On
Stop
Start operation)
This feature is useful when you want to
stop the air conditioner after you go to bed,
and start it again in the morning when you
wake up or when you return home.
Example:
COMBINED TIMER
(Setting both ON and OFF timers
simultaneously)
Start
Example:
TIMER ON
TIMER OFF
(Off
Start
Stop operation)
This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.
To start the air conditioner 2 hours after
setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to
display 2.0h on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to
display 5.0h on the TIMER OFF display .
5. Wait for the remote control to display
the setting temperature.
Off
Stop
Start
10 hours later
after setting
TIMER ON OFF
h
2 hours later
after setting
5 hours later
after setting
Set
The timer setting(TIMER ON or TIMER OFF) that in sequence occurs
directly after the set time will be activated first.
If the same time is set for both TIMER ON and TIMER OFF settings, no
timer operation is performed. The air conditioner may stop operating,
either immediately or after approximately 10 minutes.
CAUTION
!
1
The ECONOMY function enables the
unit to automatically increase(cooling) or
O
decrease(heating) 2 F per hour for the
first two hours, then hold steady for the
next 5 hours, after that the unit will stop
operation. It can maintain the most
comfortable temperature and save
energy.
NOTE: The SLEEP function is only
available under Cooling, Heating and
AUTO operations.
ECONOMY button function
TEMP
AUTO
COOL
DRY
HEAT
FAN
HIGH
MED
LOW
MODE
FAN SPEED
TIMER ON
ECONOMY
ON/OFF
TIMER OFF
FOLLOW
ME
RESET LOCK
SET TEMPERATURE( F)
SWING
LED
DISPLAY
TURBO
O