UK Jazzy 1113/RevF/Apr03
www.pridemobility.com
35
Power Module
Typically, the power module is mounted to the power base. The power module provides a power interface for the
joystick module. It routes the battery power to the motors and other powered accessories such as lights and
power seats.
Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control
and power interface between the power module, the lights, and/or the power seat actuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off
the main power if the joystick is not moved in any direction for approximately five minutes. The battery condition
meter lights on the keypad indicate sleep mode by blinking once every five seconds. To restore power and
continue, push the on/off key twice.
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors,
power module, and remote. In the event that any of them become excessively hot (above 50° C /122° F), motor
voltage is reduced. For every degree above 50° C /122° F, the voltage is reduced by 5 volts. This reduces your
power chairs speed and allows the electrical components to cool down. When the temperature returns to a safe
level, your power chair resumes its normal speed.
Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible
problems with your power chair. The battery condition meter has ten lights. The lights provide information by the
number of lights that are flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a
fault. For instance, if the first light is flashing rapidly, the battery voltage is nearly depleted. The following is a list of
the possible errors signified by the rapidly flashing meter. When you get a trouble code, contact your authorised
Pride Dealer.
FLASHING
DIAGNOSIS
SOLUTION
LIGHTS
10
High Battery Voltage
Check batteries.
9
Solenoid Brake Fault
Check motor/brake wiring.
8
Possible Controller Fault
See authorised Pride Dealer.
7
Possible Joystick Fault
See authorised Pride Dealer.
6
Inhibit Active Unplug Charger.
Check connections.
5Right Motor Wiring Fault
Check right motor wiring.
4
Right Motor Disconnected
Check right motor wiring.
3
Left Motor Wiring Fault
Check left motor wiring.
2
Left Motor Disconnected
Check left motor wiring.
1
Low Battery Voltage
Check batteries/battery wiring.