Recessed Channel Installation Guide

7

v001  |  Recessed Channel Installation Guide

End Caps

Node Recessed Channel can be provided with or without end caps. End caps are factory installed as required. 

Figure 10

Cutting Node Recessed Channels to Length 

Where possible the channel should be ordered to length based upon contractor site measurements. 

If the channel must be cut to length, the end cap should be removed, the length shall be cut and the end cap shall be 
re-attached. The maximum length that can be trimmed is defined by the position of the bridge bracket. 

END CAP

END CAP HARDWARE

Содержание Parc Node Recessed Channel

Страница 1: ...Recessed Channel Installation Guide...

Страница 2: ...3 Before You Start 3 Tools Required 3 Site Conditions Storage and Handling Instructions 3 Node Recessed Channel Installation Sequence 4 Recessed Channel to Ceiling Panels 4 Recessed Channel to Plaste...

Страница 3: ...hting and other Node devices and intermittent supporting bridge plates The recessed assembly is designed to be installed in ceilings with recessed voids between ceiling panels or plasterboard Figure 1...

Страница 4: ...the installer to ensure that the materials delivered to the installation site are safeguarded from the time of purchase until the finished ceiling is handed over However it is usually the main contra...

Страница 5: ...ssembled skirts mounting bracket bridge plates and Node face plate Note All mounting hardware and sub structure is to be supplied and installed alongside the Node Recessed Channel Lighting and other s...

Страница 6: ...LE HEX DRIVE SIZE 5 32 INSTALLATION BY OTHERS Connecting Node Channels Roll pins are supplied which must first be knocked into place then pressing together two sections of channel Node Recessed Channe...

Страница 7: ...rking out the area where the plenum box will be situated and scoring the plastic extrusion whilst still installed in the channel Once three sides have been cut the plastic can be twisted and snapped o...

Страница 8: ...red Figure 10 Cutting Node Recessed Channels to Length Where possible the channel should be ordered to length based upon contractor site measurements If the channel must be cut to length the end cap s...

Страница 9: ...inate with the services layout Node Recessed Channel Plenum Installation Sequence Mount the plenum on top of the Node channel using the pre drilled holes in the flanges Figure 12 118 11 3000 MAX LENGT...

Страница 10: ...P MECHAN CONTA CONTRO CONTR NOMENC ALL CO UNLES INSTL INSTAL BY OT TBC D NOTES PRODU TEXTU QUALIT REFER ISOMETRIC VIEW TOP VIEW 118 11 3000 MAX LENGTH GENERAL CONTRUCTION RECESSED CHANNEL WITH DIFFUSE...

Страница 11: ...m at design stage and can be purchased separately from the Node Recessed Channel Outer Node housings will be factory installed in the required locations The Node devices are installed in the housing b...

Страница 12: ...between the outer housing and device Persuasively slide the Node tool anti clockwise until the Node device is released Figure 15 Waste Disposal Management PARC Node Channels are shipped and packaged w...

Страница 13: ...to review alter amend or remove published data without notice as our policy is one of constant improvement The information contained in this installation guide is believed to be correct at the date of...

Отзывы: