GROUNDCONTROL™ REMOTE FOLLOWSPOT SYSTEM™ USER MANUAL
59
MAINTENANCE
Quad Chassis Connector Cleaning
To clean the fiber ends of panel-mount opticalCON Quad connectors, the individual LC connectors must be carefully
removed from the rear of the connector.
WARNING:
Laser radiation. Do not look directly into fiber optic cable connectors without eye protection!
Turn off source or disconnect both ends of cable before performing maintenance.
To clean quad chassis connector:
Step
1. Remove individual LC connectors from rear of chassis panel.
Step
2. Open cover of Guide Cap (
).
Step
3. Insert LC connector into Guide Cap while observing cautions as shown in
.
Step
4. Push outer shell to start cleaning LC connector end face. A "click" sound indicates the end of the cleaning
process.
Step
5. Close Guide Cap cover.
Step
6. Re-install LC connector into chassis panel.
Figure 29: Quad Chassis Connector Cleaning (Field)
Cover
LC Connector
Guide Cap
CAUTION:
Do not overly exert force during
insertion as this may cause damage to both
the LC connector and Guide Cap.
CAUTION:
Be careful not to slant LC
connector while inserting into the Guide Cap.
Dry
Cleaning Tool
(removed from rear of
opticalCON Quad)
PRO TIP!
To prevent cross
contamination clean the cable ends
and the mating connectors at the
same time.
Содержание GC RFS
Страница 1: ...SOFTWARE VERSION 2 0 WWW PRG COM GROUNDCONTROL REMOTE FOLLOWSPOT SYSTEM USER MANUAL...
Страница 6: ...IV GROUNDCONTROL REMOTE FOLLOWSPOT SYSTEM USER MANUAL Notes...
Страница 82: ...74 GROUNDCONTROL REMOTE FOLLOWSPOT SYSTEM USER MANUAL Notes...
Страница 83: ...GroundControl Remote Followspot System User Manual Version as of May 9 2016 PRG part number 02 9833 0001 A...
Страница 84: ...Production Resource Group LLC Dallas Office 8617 Ambassador Row Suite 120 Dallas Texas 75247 www prg com...