Safety Instructions

The person responsible for the instrument 

must ensure that all users understand 

these directions and adhere to them.

Symbols used

The symbols used have the following 

meanings:

WARNING 

Indicates a potentially hazardous situation 

or an unintended use which, if not avoided, 

will result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation 

or an unintended use which, if not avoided, 

may result in minor injury and/or 

appreciable material, financial and 

environmental damage.

        Important paragraphs which must be

        adhered to in practice as they enable

        the product to be used in a technically 

correct and efficient manner.

Permitted use

 

•  Measuring distances

Prohibited use

•  Using the product without instruction

•  Using outside the stated limits

•  Deactivation of safety systems and 

removal of explanatory and hazard 

labels

•  Opening of the equipment by using tools 

(screwdrivers, etc.)

•  Carrying out modification or conversion 

of the product

•  Use of accessories from other 

manufacturers without express approval

•  Deliberate dazzling of third parties; also 

in the dark

•  Inadequate safeguards at the surveying 

site (e.g. when measuring on roads, 

construction sites, etc.)

•  Deliberate or irresponsible behaviour on 

scaffolding, when using ladders, when 

measuring near machines which are 

running or near parts of machines or 

installations which are unprotected

•  Aiming directly in the sun

Hazards in use

WARNING

Watch out for erroneous measurements if 

the instrument is defective or if it has been 

dropped or has been misused or modified. 

Carry out periodic test measurements.

Particularly after the instrument has been 

subject to abnormal use, and before, 

during and after important measurements.

CAUTION

Never attempt to repair the product 

yourself. In case of damage, contact a 

local dealer.

WARNING

Changes or modifications not expressly 

approved could void the user’s authority 

to operate the equipment.

Limits of use

 

     Refer to section "Technical data".

     The device is designed for use in areas 

permanently habitable by humans. Do not 

use the product in explosion hazardous 

areas or in aggressive environments.

i

i

Prexiso P70DLI

9

EN

Содержание P70DLI

Страница 1: ...P70DLI RECHARGEABLE DUAL LASER DISTANCE MEASURE IMPORTANT Read before Using 2 WARRANTY LIMITED YEARS FUNC UNITS C OFF...

Страница 2: ...suring Functions 5 Single measuring Continuous measuring Area Volume Pythagoras 2 point Pythagoras 3 point Angle measurement 5 5 5 6 6 7 7 Technical Data Message Codes Care Disposal Warranty 8 8 8 8 8...

Страница 3: ...for the product must ensure that all users understand these directions and adhere to them 2 EN FUNC UNITS C OFF ON Measuring Measuring direction switch Clear Off Add Sub Measuring Reference Single mea...

Страница 4: ...rement reference will be reset when recovering the system 5 sec 3 sec 3 sec Device is turned OFF If the info icon appears with a number observe the instructions in section Message Codes Example Switch...

Страница 5: ...direction starts from the top to the bottom 3 Long press button again to change to measuring in two direction at the same time 3 sec 3 sec 4 The result is shown in the main line and the measured dista...

Страница 6: ...Single measuring Target surfaces Measuring errors can occur when measuring to colourless liquids glass styrofoam or semi permeable surfaces or when aiming at hight gloss surfaces Against dark surface...

Страница 7: ...e measured distance above Pythagoras 2 point Prexiso P70DLI 6 EN 25 286 m 7 i The result is shown in the main line and the measured distance above 24 352 m3 1 2 3 4 6 Volume Aim laser at first target...

Страница 8: ...ser at first target point 3 Aim laser at second target point Perpen dicular to the measuring surface 90 4 Aim laser at third target point 5 The result is shown in the main line and the measured distan...

Страница 9: ...ific treatment and waste management can be downloaded from our homepage Warranty The Prexiso P70DLI has two years warranty For further information on this contact your dealer Subject to change drawing...

Страница 10: ...e of accessories from other manufacturers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads constru...

Страница 11: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installati...

Страница 12: ...eam may be hazardous to the eyes Wavelength 620 690 nm Maximum radiant output power for classification 1 mW Pulse duration 400 ps Pulse repetition frequency 320 MHz Beam divergence 0 16 x 0 6 mrad Lab...

Отзывы: