3. Operation 

Description of LCD graphic symbol  

 

Stop-powered Status for Loads  
Stop the battery charging

 

Power to the load status, the load circuit without current 
Bulk charging the battery

 

The load circuit with current      

  

Float charging the battery 

        

 

   

  

Load

 

  

 

The system is working correctly 

 

 

Solar Panel 

 

 

 

The system is not working properly  

 

  

 

 

Load sensor control 

 

 

Battery charge capacity instruction

 

   

  

Load timer control 

 

 

  

Battery 

                  

2 Description of Button Function

     

Interface loop switch button, use the button to cycle between pages in each switch cycle sequence shown 

in (figure 1) 

Adjustment of parameters plus buttons. In addition, at the state in the parameter view, long press the 

button more than 5 seconds, all parameter to restore factory setting. 

 

 

:

 Adjustment of parameters minus button. In addition, in the main interface, click this button to switch the 

load.  

 
 
 

          

   

   

  

   

 

        

  

Battery Voltage        Battery                Solar Panel              Load                Accumulated  

            (main interface

     temperature     charge current   discharge current   charging power(Ah)

 

          

   

 

 

 

   

   

   

   

        

Load working    High Voltage        Low voltage       Low Voltage       Accumulated 

                   Mode        Disconnection (HVD) Reconnection (LVR) Disconnection (LVD) Discharging power (Ah) 

                                        Figure 1 
 
3 View and set the parameters: 

The  controller  will  default  entry  “battery  voltage”  interface  after  correct  power-on.  This  is  the  main 

interface. Use the button

 

could in turn visit the following parameters interface. If that interface could be set, 

long press the button

(>

5seconds

numbers start flashing

To enter the parameter setting interface; set 

out the parameter interface after long press the button

 again. (The numbers stops flashing)  

 
 
 

3.1 Battery Voltage of View 

As shown on the right, displays the value for current battery voltage. This interface (based interface)    
displays charge status, discharge status, battery capacity and battery voltage. 

 

 
  

 

3.2 The load on/off control

   

 

View the interface in the battery voltage could be used key 
 

 

On, off the load 

In other interface, the key there is no such feature. 

 

Содержание CMP 50

Страница 1: ...0 6048 9600 19 Germany Email info prevent germany com Web www preVent germany com 1 5 Intelligent Solar Charge Controller User s Manual Please read this manual carefully before you use this product Catalogue 1 Product Introduction 3 2 Installation 4 3 Operation 5 4 Common Fault and Handling 10 5 Technical Data 11 ...

Страница 2: ...hat is conductive to reducing the line voltage drop Recommended 30A with 10mm cable Check weather the installation sites compliance with the relevant safety requirements Please avoid the damp dusty there is a place flammable explosive and corrosive gases use the controller to install Install the controller into a fixed vertical plane See section 5 of the pore size and pore spacing In order to ensu...

Страница 3: ...inus button In addition in the main interface click this button to switch the load Battery Voltage Battery Solar Panel Load Accumulated main interface temperature charge current discharge current charging power Ah Load working High Voltage Low voltage Low Voltage Accumulated Mode Disconnection HVD Reconnection LVR Disconnection LVD Discharging power Ah Figure 1 3 View and set the parameters The co...

Страница 4: ...ave the settings 3 9 View and set the Low Voltage Reconnection As shown on the right shows the values for the LVR voltage Under the LVD protection in the controller when the battery voltage is restored to the higher voltage than LVR voltage the controller will re connect the load circuit Long press the button 5seconds in this interface numbers start flashing that has entered the LVR setup interfac...

Страница 5: ...t Protection state Check the load if there is damage or not if there is cable short circuit or not after trouble shooting short press the button for restoration Solar Panel Fault and Treatment Symbol flashing represent the controller was not detected solar panels within 24hours Check if there is a connection from solar panel check if there is an open circuit between solar panels with controller Lo...

Отзывы: