Intelligent Solar Charge Controller 

User’s Manual 

 
 

 

 

 

 

Please read this manual carefully before you use this product. 

 

Catalogue 

 

1. Product Introduction   

 

2. Installation 

 

 

 

3. Operation  

 

 

 

4. Common Fault and Handling  

10 

5. Technical Data   

 

 

11

 

Содержание CMP 50

Страница 1: ...0 6048 9600 19 Germany Email info prevent germany com Web www preVent germany com 1 5 Intelligent Solar Charge Controller User s Manual Please read this manual carefully before you use this product Catalogue 1 Product Introduction 3 2 Installation 4 3 Operation 5 4 Common Fault and Handling 10 5 Technical Data 11 ...

Страница 2: ...hat is conductive to reducing the line voltage drop Recommended 30A with 10mm cable Check weather the installation sites compliance with the relevant safety requirements Please avoid the damp dusty there is a place flammable explosive and corrosive gases use the controller to install Install the controller into a fixed vertical plane See section 5 of the pore size and pore spacing In order to ensu...

Страница 3: ...inus button In addition in the main interface click this button to switch the load Battery Voltage Battery Solar Panel Load Accumulated main interface temperature charge current discharge current charging power Ah Load working High Voltage Low voltage Low Voltage Accumulated Mode Disconnection HVD Reconnection LVR Disconnection LVD Discharging power Ah Figure 1 3 View and set the parameters The co...

Страница 4: ...ave the settings 3 9 View and set the Low Voltage Reconnection As shown on the right shows the values for the LVR voltage Under the LVD protection in the controller when the battery voltage is restored to the higher voltage than LVR voltage the controller will re connect the load circuit Long press the button 5seconds in this interface numbers start flashing that has entered the LVR setup interfac...

Страница 5: ...t Protection state Check the load if there is damage or not if there is cable short circuit or not after trouble shooting short press the button for restoration Solar Panel Fault and Treatment Symbol flashing represent the controller was not detected solar panels within 24hours Check if there is a connection from solar panel check if there is an open circuit between solar panels with controller Lo...