1. Support N-level organizational structure
management and user-access manage-
ment
2. Support search devices
3. Support the display of the front-end equip-
ment list
4. Support multiple video windows and the
screen control
5. Support video polling
6. Support snapshot
7. Support local amplification
8. Support client logs
9. Support small medium and large data-
bases, such as SOL/ MYSQL/XML data
10. Support EXCEL software to add and edit
devices
11. Support intelligent video transmission
protocol
12. Support coordinated operations of multi-
servers
13. Support real-time monitoring, video
alarm, automatic video recording and
video playback
14. Support network and load balancing
15. Support batch network upgrading of
multiple equipment
16. Support customized user interface and
multi-language
17. Support electronic map
18. Support four-channel simultaneous play-
back
19. Support multi-connected devices and
video equipment
20. Support XML data storage
Reset (Device cannot access the camera)
1. Web port is changed.
2. IP address is changed.
3. Other unknown reasons.
How to connect IP Camera?
1.Enter network settings–streaming media settings
2. Enter system settings–account administration-
modify the account password-require authentica-
tion–use new password to log in
Operation errors after installing the client
Follow the steps below
1. Choose “start”-“program”-“unit client”- “manually
register DLL”- “operation”.
2. Unload the client, then re-install (close the client
and webpage).
How to get the serial number?
1. Search Camera function, and serial number will be
shown.
2. Enter system settings- get the serial number.
How to begin recording?
1. Add device.
2. Configuration administration- recording set.
Which brands of NVRs can be connected
to our products?
At present, our IPC products can support following
NVR brands: Millstone, Axxon Smart, Nuuo, Luxriot,
Axis, Hikvision, Dahua, Histream, Geovision, LG,
Acumen, HUNT, and etc.
Why can not switch the data?
1. The IP address is wrong.
2.The port and physical address are not bound.
3. Check the port mapping or reset the firewall.
Why can not access the Camera after up-
date?
Clean browser cache.
Steps: open IE, click “Tools” and select “Internet
options”, then you can see “Temporary Internet files”.
Click “Delete Files”. A dialog will be prompted, then
you need to check “Delete all offline content” and
click “OK”.
Also you can click “Start” and select “Run", then
enter “cmd” and “arpd” in “Command Prompt” inter-
face. Re-access the IP camera.
How to access IPC through webpage?
1.Enter the IPC address in the Internet Explorer.
(default address is: 192.168.1.10)
2.You are prompted to install this plug-in. Click
“Install”. If the client computer intercepts installing
this plug- in, please allow installation.
3.Excluding the above reasons, if the plug-in installa-
tion still fails, change your IE security level and
allow some controls to start.
4.Install the control, log in again to refresh.
Thank you for purchasing our HD IP Camera. To
have a total understanding of it, please read the
following instructions.
1.1 Before using the camera, please read this
manual carefully and keep it safe for later use.
1.2 Installation should be proceeded under profess-
sional guidance and follow manufacturer’s
instructions. Do not dismantle it without
authorization.
1.3 In order to protect the sensor, do not expose lens
into intense light source for a long time.
1.4 Do not touch the sensor directly. Please cover
the dustproof cover when the camera is not
being used.
1.5 Please use a soft dry cloth to clean the camera.
If it is difficult to clean the dirt, wipe the camera
with water and detergent, then dry it.
1.6 Do not place the camera under air conditioning
vent. If not, the lens will be blurred with moisture.
1.7 Please ensure that the power supply is turned off
when installing, opening and cleaning camera.
1.8 If the camera was broken, for example, power
cord or plug is damaged; splash liquid or foreign
matter falls into the camera; the camera get
wetted or damped, please contact the manufac-
turers or the maintenance center. (Any modifica-
tion or maintenance without permission, you
should be responsible for the consequences)
The symbol is intended to remind the
users of
important operations
and
maintenances
.
The symbol is intended to remind the
users of the existence of uninsulated
‘
dangerous voltage’
. Within the prod-
uct’s enclosure, there may be sufficient
magnitude of current, which can consti-
tute a
risk of electric shock
.
CAUTION:
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE THE COVER OR BACK.
NO USER SERVICEABLE PARTS INSIDE.
RISK OF ELECTRIC SHOCK
CAUTION
PREVENT ELECTRIC SHOCK AND RISK OF FIRE.
Notes
:
●
The power source
must pass safety certifications. Its
output voltage, current, voltage polarity
and operating
temperature
must match the camera’s requirements
.
●
When using the camera under thunderbolt condition
,
please install anti-thunder device or cut off the power
supply
.
●
In order to capture high-quality pictures, please ensure
the stability and smoothness of the network.
CMS Client Features
Problem and Solution
Introduction