GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY

  

The MODEL ST263 is intended for use in the electromagnetic environment specified below. The customer or the user of the MODEL 
ST263 should assure that it is used in such an environment.

Immunity test

IEC 60601

test level

Compliance level

Electromagnetic environment – guidance

Electrostatic
discharge (ESD)
IEC 61000-4-2

±6 kV contact
±8 kV air

±6 kV contact
±8 kV air

Floors should be wood, concrete or 
ceramic tile. If floors are covered with 
synthetic material, the relative humidity 
should be at least 30 %.

Electrical fast
transient/burst
IEC 61000-4-4

±2 kV for power
supply lines and patient 
coupled lines

±2 kV for power
supply lines and patient 
coupled lines

Mains power quality should be that 
of a typical commercial or hospital 
environment.

Surge
IEC 61000-4-5

±1 kV line(s) and neutral

±1 kV line(s) and neutral

Mains power quality should be that 
of a typical commercial or hospital 
environment.

Voltage dips, short 
interruptions and voltage 
variations
on power supply
input lines
IEC 61000-4-11

<5 % U

T

(>95 % dip in U

T

)

for 0,5 cycle
40 % U

T

(60 % dip in U

T

)

for 5 cycles
70 % U

T

(30 % dip in U

T

)

for 25 cycles
<5 % U

T

(>95 % dip in U

T

)

for 5s 

<5 % U

T

(>95 % dip in U

T

)

for 0,5 cycle
40 % U

T

(60 % dip in U

T

)

for 5 cycles
70 % U

T

(30 % dip in U

T

)

for 25 cycles)
<5 % U

T

(>95 % dip in U

T

)

for 5s

Mains power quality should be that 
of a typical commercial or hospital 
environment. If a dips or an interruption 
of mains power occurs, the current of the 
MODEL ST261 may be dropped off from 
normal level, it may be necessary to use 
uninterruptible power supply or a battery.

Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8

3 A/m

3A/m

Power frequency magnetic fields 
should be at levels characteristic of a 
typical location in a typical commercial 
or hospital environment.

NOTE    U

T

 is the a.c. mains voltage prior to application of the test level

  

Содержание SonicLift ST280

Страница 1: ...1 ...

Страница 2: ...perate properly use the Electrolyte Conductive Gel that comes with your device For important information about safety and how to use the device read the full Instructions for Use booklet Contact the experts at Pretika for any assistance in helping you get started Customer Service Contact 1 949 481 8818 Email customerservice pretika com or visit our website at www pretika com Hours of Operation Mon...

Страница 3: ... Warnings 7 Precautions 8 Risks 9 Benefits 10 Getting Started 11 To Charge Batteries 11 How to Use 12 Buttons Indicator Lights 13 Treating Target Areas 14 What to Expect 14 Device Maintenance 15 Trouble Shooting 16 Service 17 Specifications 18 Assistance and Contact Information 18 Warranty 19 ...

Страница 4: ...4 Package Contents and Components Package Contents Treatment Spheres Hand Piece Components 3 Power Button 6 oz 177mL Conductive Gel 1 2 1 2 3 4 3 4 ...

Страница 5: ...rent Device continually alternates between the positive and negative probes and allows you to adjust the current output from 0 to 400 microamps for a personalized comfort level For your Micro Current Device to operate properly a conductive solution is needed Therefore it is important to first apply the Conductive Gel to the skin areas to be treated Then following the natural contours of your face ...

Страница 6: ...in growth that bleeds or will not heal Do not use if you have a history of light triggered seizures It is recommended that you test a small less sensitive patch of skin i e such as the forearm Micro Current Device should not be used in the following areas Around the mouth Orbicularis Oris Eye areas Orbicularis Oculi Muscle Mid line facial and throat area vertical center Micro Current Device should...

Страница 7: ...evice from water including bath and shower 4 Keep device away from heated surfaces 5 Never drop or insert any object into any openings on the device 6 Never operate this device if it has been damaged If it is not working properly if it has been dropped or damaged or submerged in water discontinue use 7 Do not disassemble the device as this may cause damage malfunction or personal injury There are ...

Страница 8: ... by patients with suspected or diagnosed heart problems Caution should be used by patients with suspected or diagnosed epilepsy Caution should also be used in the presence of the following When there is a tendency to hemorrhage following acute trauma or fracture Over areas of the skin which lack normal sensation Some patients may experience skin irritation or hypersensitivity due to the electrical...

Страница 9: ...al conditions Not likely to happen Damage to device User fails to follow maintenance instructions Not likely to happen Lack of product effectiveness Battery explodes Not likely to happen Can cause serious burns Short circuit wiring Not likely to happen Can cause overheating of handle which may result in user discomfort User attempts to use product past recom mended maximum exposure per site per da...

Страница 10: ...col Methylisothiazolinone Cellulose Polymer BENEFITS LIKELIHOOD OF BENEFIT EFFECTS TO USER Improve your facial tone Users of this device can obtain benefit from using it only if they read and understand all information in the user manual and follow exactly all the instructions in the user manual ...

Страница 11: ...firmly pressing into place keeping silicone seal in place and then replace the outer battery cover by aligning the lower tab into slot and pressing firmly to close Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries To dispose of alkaline batteries place in the trash normal municipal waste Recycling of batteries at your local recycling...

Страница 12: ... with the conductivity Basic Treatment 5 minutes When using Micro Current Device make sure you are positioned in front of a mirror in a well lit room Step 1 For your Micro Current Device to operate properly a conductive solution is needed Therefore it is important to first apply the Conductive Gel to the skin areas to be treated Ensure the entire area being treated is saturated with the Conductive...

Страница 13: ...ntil the entire facial area has been treated avoiding eye area and around the mouth Step 4 Remove the Conductive Gel with a warm damp washcloth Step 5 Be sure to turn off your device and gently wipe off any Conductive Gel residue on the sphere with a dry or slightly damp cloth Never submerge your device in water or use an excess of liquid when cleaning your device Step 6 Apply your favorite anti a...

Страница 14: ...n skin smoothness After 2 Weeks of Treatment A vast majority of users will see a reduction in the overall signs of aging particularly an increase in skin firmness After 4 Weeks of Treatment Many users will see overall better skin condition compared to before treatment This includes an improvement in the healthy appearance of the skin and a reduction in fine lines and wrinkles Step 1 PREP Apply any...

Страница 15: ... up on the surface by an accumulation of product Gently wiping the spheres clean after each treatment helps ensure that every anti aging treatment is the best one Since the Micro Current Device is an electrical device it s essential that you make sure that product like gel or makeup doesn t find its way into the seams or on any of the electrical connections A water dampened washcloth can be used t...

Страница 16: ...al To learn about recycling or disposal programs in your area search E waste recycling or disposal online You can also contact your city directly or look into your local electronics store policy If Do This Device turns off Check and replace batteries Device will not turn on Check and replace batteries Device shuts off in mid treatment or only after a few treatments Check and recharge batteries If ...

Страница 17: ...e prompt repair provide complete legible name address and phone number information RMA number and a note indicating the nature of the product defect and a copy of the original invoice issued for purchase of the unit We will Repair or Replace at our sole discretion product at no charge Ship unit to the manufacturer in the original container with all accessories and information as required above Out...

Страница 18: ... Maximum Output Voltage Transport Store Environmental Specifications Ambient Temperature 0 degrees C to 60 degrees C RH 10 to 90 Technical description 1 Warning that the use of accessories transducers and cables other than those specified with the exception of transducers and cables sold by the manufacturer of the MODEL ST280 as replacement parts for internal components may result in increased EMI...

Страница 19: ...roup 1 The MODEL ST280 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The MODEL ST280 is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies bui...

Страница 20: ...5 1 kV line s and neutral 1 kV line s and neutral Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5s 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip i...

Страница 21: ... electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and ...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...Facial Toning Lift Firm and Tone Skin ...

Отзывы: