background image

33

6.0

Replacement Parts

8

6

2

1

3

7

4

5

Fig. 11: PRESTIGE Solo 299/399 Burner Components

Item

Part #

Description

1

PARKIT72

Combustion Chamber 2-in-1 Insulation

2

PARKIT74

Burner Head Assembly (with Gasket)

3

PARKIT71

Blower Assembly (with Gasket)

4

PARKIT18

Blower Clamp

5

PARKIT19

Blower Gasket

6

PARKIT75

Burner Plate Assembly

7

PARKIT79

Gas Valve

8

PARKIT16

Igniter Assembly

Содержание PRESTIGE Solo 110

Страница 1: ... to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier prestige User s Information Manual Date...

Страница 2: ... Area 6 3 1 2 Check Combustion Air Inlets 6 3 1 3 Check Temperature Display and Pressure Gauge 6 3 2 Monthly Maintenance 7 3 2 1 Check Vent Piping 7 3 2 2 Check Combustion Air Inlet Piping 7 3 2 3 Check Pressure Relief Valve 7 3 2 4 Check Condensate Drain System 7 3 2 5 Check Automatic Air Vents If Used 7 3 3 6 Month Maintenance 8 3 3 1 Check Water and Gas Piping 8 3 3 2 Operate Pressure Relief Va...

Страница 3: ...olo 155 175 250 Jacket Components 24 Solo 299 399 Jacket Components 25 Solo 80 110 Internal Components 27 Solo 155 175 250 Internal Components 28 Solo 299 399 Internal Components 29 Solo 80 110 Excellence Burner Components 31 Solo 155 175 250 Burner Components 32 Solo 299 399 Burner Components 33 Control Module Enclosure 34 Display Module Enclosure 34 Section VII Notes Notes 35 ...

Страница 4: ...of a carbon monoxide detector and alarm with battery back up Installation of a carbon monoxide detector and alarm that complies with NFPA 720 ACV Triangle Tube accepts no liability for any dam age injury or loss of life resulting from incorrect installtion from alteration of any factory supplied parts or from the use of parts or fittings not speci fied by ACV Triangle Tube If there is a conflict o...

Страница 5: ...ressurized to 12 psig prior to startup The unit will shut down if the pressure falls below 10 psig Should overheating occur or the gas supply fail to shut off DO NOT turn OFF or disconnect the elec trical supply to the pump Instead shut off the gas supply at a location external to the appliance Do not use this unit if any part has been under water Immediately call a qualified service technician to...

Страница 6: ...Product Safety Information 3 Page left intentionally blank ...

Страница 7: ...gas spillage or water leakage into the surrounding area Please read the following information If contami nating chemicals will be present near the location of the combustion air inlet the installer should pipe the combustion air inlet to another location per the PRESTIGE installation manual WARNING WARNING 1 1 Potential Contaminating Products Spray cans containing chloro fluorocarbons Permanent Wa...

Страница 8: ...iring and ground wiring Check all control wiring and connections Check burner flame pattern stable and uniform 2 1 2 Poor Performance or Combustion Clean heat exchanger and flue ways Remove burner assembly and clean burner head using compressed air only Once the maintenance items are completed review the service with the owner 2 2 Owner Maintenance 2 2 1 Periodic Check the area around the unit Che...

Страница 9: ...re pipe the combus tion air inlet piping and locate the combustion air intake away from the contaminated areas WARNING NOTICE WARNING 1 Combustible flammable materials Do not store combustible materials gasoline or other flammable vapors or liquids near the unit Remove immediately if found 2 Air contaminates Products containing chlorine or fluorine if allowed to contaminate the com bustion air wil...

Страница 10: ...es can be emitted into the surrounding area causing severe personal injury or death 2 While the unit is running check the discharge end of the condensate drain tubing Ensure no WARNING WARNING flue gas is leaking from the condensate drain tubing by holding your fingers near the opening 3 If you notice flue gas leaking this indicates a dry condensate drain assembly Fill the condensate drain assembl...

Страница 11: ...st be connected to the relief valve outlet and directed to a safe place of dis posal This discharge line must be installed by a qualified service technician or heating plumbing installer in accordance with the PRESTIGE installa tion manual The discharge line must be terminated so as to eliminate possibility of severe burns or property damage should the valve discharge 2 Read the temperature displa...

Страница 12: ...t and the sys tem piping is not hot follow the instructions To Turn Off Gas to Appliance below and call your service technician or gas supplier 11 Replace the front jacket panel Make sure the panel is seat ed firmly in place and all mounting screws are tightened If you do not follow these instructions exactly a fire or explosion may result caus ing property damage personal injury or loss of life 1...

Страница 13: ...entering information The INSTALLER button the small round button provides the installing con tractor with full access to all available features after entering a password Figure 2 ACVMax Navigation Buttons The Main Menu can be entered from the Home Screen by pressing the OK button The menu system utilizes icons to represent each selection The current selected menu is displayed as a reversed image w...

Страница 14: ...11 5 0 ACVMax Operation 5 2 ACVMax Menu Structure ...

Страница 15: ...dicate the current firing rate The status line displays the current operating state of the Prestige See page 13 for a list of all Status Line Messages 5 3 Home Screen The Home Screen presents status information in a very user friendly way so that the current state of the boiler can be quickly accessed The screen backlight will illuminate when any button is pressed and remain illuminated for five m...

Страница 16: ...ire until the call blocking time has elapsed DHW Burner Delay The burner will not fire until the call blocking time has elapsed CH Setpoint Reached The burner is not fired because the supply system water temperature exceeds the setpoint The central heating circulator continues to operate and the burner will fire again once the supply system water temperature drops below the set point DHW Setpoint ...

Страница 17: ...een by pressing the OK button The menu system utilizes icons to represent each selection The currently selected menu is displayed as a reversed image with a text description shown at the top of the display Menus can be entered by highlighting the desired icon and pressing the OK button ...

Страница 18: ... selecting the faucet icon and pressing the OK button to toggle operation between enabled and disabled A faucet icon with an X through it indicates that the domestic hot water function is disabled This icon is also displayed on the Home Screen when disabled Currently selected menu Heating Enabled CH DHW Operation 5 5 CH DHW Operation Menu The CH DHW Operation Menu can be entered from the Main Menu...

Страница 19: ...r Status Heating Call DHW Call Boiler Firing Rate Ionization Current Boiler Setpoint Standby No No __ µA __ Boiler Information abc de f bbb b abc de f bb abc de abc de f bbb b abc de f bb abc d a b c d e f b b b b a b c d e f b b a b c d e a b c d e f b b b b a b c d e f b b f b g a b c d Press OK Button 194 68 24 00 16 00 8 00 0 00 Boiler Setpoint Some information items include a logging function...

Страница 20: ...utdoor Temp Displays the current outdoor temperature DHW Storage Temp Displays the current DHW storage temperature when Indirect Water Heater Sensor PSRKIT22 is installed External Modulation Signal Displays the current external modulation signal being received from an external controller Pressure Displays the current system pressure CH Ignitions Displays the number of central heating ignitions sin...

Страница 21: ... OK Button Lockout Details displays the lockout at the top of the screen followed by a snapshot of the boiler information recorded at the time of the lockout Press the UP or DOWN buttons to scroll through additional information items Lockout History 1 Low water 2 No error 3 No error 4 No error 5 No error 6 No error 5h ago 25h ago 25h ago 25h ago 25h ago 25h ago Lockout Details Low Water Boiler Sta...

Страница 22: ...u can then be entered from the Home Screen to help diagnose the problem Select the Home Screen icon at the bottom of any menu screen to return to the Lockout Screen Water level has fallen below 0 5bar Increase pressure to normal range Low Water If problem persists call for service E37 5 9 Lockout Screen The Lockout Screen replaces the Home Screen if a lockout occurs The screen backlight will also ...

Страница 23: ... sensor reading is not changing E17 Return Sensor Stuck Return sensor reading is not changing E18 Sensor Failure Supply or return sensor reading changed very rapidly E21 Internal Control Fault A D conversion error E30 Supply Sensor Shorted A short circuit has been detected in the boiler supply temperature sensor circuit E31 Supply Sensor Open An open circuit has been detected in the boiler supply ...

Страница 24: ... Open An external automatic reset boiler limit has opened E81 Sensor Drift Supply and return temperatures are not equal E89 Incorrect Setting A parameter setting is in conflict with another setting E90 Firmware Mismatch Control module and display firmware versions are incompatible E91 System Sensor Shorted A short circuit has been detected in the system temperature sensor circuit E92 System Sensor...

Страница 25: ...art please provide the model number and description and or part number of replace ment part Use only genuine ACV Triangle Tube replacement parts to ensure warranty coverage and to avoid damage to appliance and improper operation of appliance Contact ACV Triangle Tube at 856 228 8881 or www triangletube com for list of distributors nearest you WARNING ...

Страница 26: ...80 110 Jacket Components Item Part Description 1 PAJKT01 Front Jacket Panel with insulation 2 PAJKT03 Left Side Jacket Panel with insulation 3 PAJKT21 Right Side Jacket Panel with insulation 4 PAJKT04 Top Panel 5 PSRKIT21 Wall Mounting Bracket with Hardware ...

Страница 27: ... 175 250 Jacket Components Item Part Description 1 PAJKT01 Front Jacket Panel with insulation 2 PAJKT03 Left Side Jacket Panel with insulation 3 PAJKT21 Right Side Jacket Panel with insulation 4 PAJKT12 Top Panel 5 PSRKIT21 Wall Mounting Bracket with Hardware ...

Страница 28: ...Components Item Part Description 1 PAJKT15 Front Jacket Panel with insulation 2 PAJKT16 Left Side Jacket Panel with insulation 3 PAJKT22 Right Side Jacket Panel with insulation 4 PAJKT17 Top Panel Front 5 PAJKT18 Top Panel Rear 6 PSRKIT21 Wall Mounting Bracket with Hardware ...

Страница 29: ...26 6 0 Replacement Parts Page left intentionally blank ...

Страница 30: ...ADPT07 Vent Outlet Combustion Air Inlet Adapter 3 PARKIT02 Polypropylene Vent Pipe 4 PTRKIT123 Supply Return Temperature Sensor 5 PARKIT01 Flue Temperature Sensor 6 PARKIT04 LWCO Pressure Sensor 7 PARKIT05 Condensate Drain Assembly 8 PARKIT06 Boiler Piping Return Assembly 9 PARKIT07 Boiler Piping Supply Assembly 10 PARKIT13 Polypropylene Condensate Pan ...

Страница 31: ...dy Solo 250 2 PTADPT07 Vent Outlet Combustion Air Inlet Adapter 3 PARKIT08 Polypropylene Vent Pipe 4 PTRKIT122 Supply Return Temperature Sensor 5 PARKIT01 Flue Temperature Sensor 6 PARKIT04 LWCO Pressure Sensor 7 PSRKIT44 Condensate Drain Assembly 8 PARKIT46 Boiler Piping Return Assembly 9 PARKIT47 Boiler Piping Supply Assembly 10 PARKIT43 Polypropylene Condensate Pan Solo 155 PARKIT53 Polypropyle...

Страница 32: ...er Body Solo 399 2 PTADPT08 Vent Outlet Combustion Air Inlet Adapter 3 PARKIT09 Polypropylene Vent Pipe 4 PARKIT78 Supply Return Temperature Sensor 5 PARKIT01 Flue Temperature Sensor 6 PARKIT04 LWCO Pressure Sensor 7 PSRKIT44 Condensate Drain Assembly 8 PARKIT76 Boiler Piping Return Assembly 9 PARKIT77 Boiler Piping Supply Assembly 10 PARKIT73 Polypropylene Condensate Pan Solo 155 ...

Страница 33: ...30 6 0 Replacement Parts Page left intentionally blank ...

Страница 34: ...ion 1 PARKIT12 Combustion Chamber 2 in 1 Insulation 2 PARKIT14 Burner Head Assembly with Gasket 3 PARKIT11 Blower Assembly with Gasket 4 PARKIT18 Blower Clamp 5 PARKIT19 Blower Gasket 6 PARKIT15 Burner Plate Assembly 7 PARKIT17 Gas Valve 8 PARKIT10 Venturi Solo 80 PARKIT20 Venturi Solo 110 9 PARKIT16 Igniter Assembly ...

Страница 35: ... Solo 175 250 2 PARKIT54 Burner Head Assembly with Gasket 3 PARKIT51 Blower Assembly with Gasket Solo 155 175 PARKIT61 Blower Assembly with Gasket Solo 250 4 PARKIT18 Blower Clamp 5 PARKIT19 Blower Gasket 6 PARKIT45 Burner Plate Assembly Solo 155 PARKIT55 Burner Plate Assembly Solo 175 250 7 PARKIT59 Gas Valve 8 PARKIT30 Venturi Solo 155 PARKIT40 Venturi Solo 175 PARKIT50 Venturi Solo 250 9 PARKIT...

Страница 36: ...ts Item Part Description 1 PARKIT72 Combustion Chamber 2 in 1 Insulation 2 PARKIT74 Burner Head Assembly with Gasket 3 PARKIT71 Blower Assembly with Gasket 4 PARKIT18 Blower Clamp 5 PARKIT19 Blower Gasket 6 PARKIT75 Burner Plate Assembly 7 PARKIT79 Gas Valve 8 PARKIT16 Igniter Assembly ...

Страница 37: ... 6 5 Fig 12 PRESTIGE Display Control Module Enclosures Item Part Description 1 PTRKIT109 Pressure Gauge 2 PTSWI01 Power Switch 3 PTSWI02 Power Switch Cover 4 PADIS02 Display Module 5 PACON01 Control Module 6 PAHNG01 Control Box Hinges ...

Страница 38: ...7 0 Notes 35 SECTION VII NOTES ...

Страница 39: ...36 7 0 Notes ...

Страница 40: ...ctor to assure maximum heat exchange Compact and light weight Available in 8 sizes that can accommodate any size pool or spa Exclusive tank in tank design Stainless steel construction Available in 7 sizes Limited LIFETIME residential warranty 6 year limited commercial warranty Self cleaning self descaling design For domestic water snow melting radiant floor refrigeration Plates made of stainless s...

Отзывы: