polarity" output scheme these two wires produce the opposite polarity at the opposite time.  To better understand
this, refer to the table below:

The output of these wires has a maximum switching capability of 300mA.  Many vehicles today have factory door
lock relays which can be connected directly to these outputs, however always confirm that the factory relays in your
particular vehicle do not exceed the rated 300mA output of the units door lock/unlock circuit. Plug the two pin
connector of the door lock/unlock harness into the mating connector shell of the control module.  Determine the
door lock circuit of the vehicle you are working on and wire according to the diagrams shown.

WIRING FOR "GROUND PULSE" DOOR LOCK CIRCUITS:
This is a system commonly used on most import vehicle's factory door lock/unlock systems and with a few
domestic vehicles which employ factory "keyless entry" systems.  In this application, the Red wire serves as the
"Lock" output, providing a ground pulse during the arming sequence and the Green wire serves as the "Unlock"
output, providing a ground pulse during the disarming sequence.
Connect the Red wire to the low current ground factory door "Lock" signal wire leading from the factory switch to the
factory door lock relay. Connect the Green wire to the low current ground factory door "Unlock" signal wire leading
from the factory switch to the factory door unlock relay.

WIRING FOR "POSITIVE PULSE" DOOR LOCK CIRCUITS:
This is a system commonly used on many domestic vehicle's factory door lock/unlock systems, particularly
General Motors and Chrysler, although not on all models. (Please see the note regarding "5-Wire Reverse Polarity
Door Lock Systems"). In this application, the Green wire serves as the "Lock" output, providing a positive pulse
during the arming sequence and the Red wire serves as the "Unlock" output, providing a positive pulse during the
disarming sequence.
Connect the Green wire to the low current positive (+12VDC) factory door "Lock" signal wire leading from the factory
switch to the factory door lock relay. Connect the Red wire to the low current positive (+12VDC)  factory door "Unlock"
signal wire leading from the factory switch to the factory door unlock relay.

4 WIRE POLARITY REVERSAL and 5 WIRE ALTERNATING DOOR LOCK CONTROL CIRCUITS:
In these applications, the AS-9159 Door Lock Interface (or equivalent 30 Amp. automotive type relays) must be used.
Refer to the Audiovox Door Lock Wiring Supplement for proper connection to these types of circuits.

PLUG-IN CONNECTIONS AND COMPLETING THE INSTALLATION:
Now that all the other components have been installed and most of the main connections completed, it is time to
finish connecting the remaining plug-in components and completing the installation.  Even though these are plug-
in connections and the plugs have been shaped such that they cannot be plugged in wrong, please read and
follow the instructions below for each connection to make certain each component is properly installed.

DASH MOUNTED LED

2-PIN White Plug w/2 Wires; Red and Blue
The Red and Blue wires in the 2-PIN mini white connector control the anode and cathode of the dash mounted
LED.  Route the twin lead Red and Blue wires from the LED to the control unit and plug the two pin connector into
the mating white mini connector shell of the control module. Do not force the connector, it will only plug in one way.
OPTIONAL SHOCK SENSOR
4-PIN White Plug w/4 Wires; Red, Black, Blue, and Green
The Red (+12 volt), Black (ground), Blue (pre-detect) and Green (full trigger when armed) wires loaded into the
white connector shell are the inputs/outputs of the shock sensor. Route the 4 wire harness from the shock sensor
location to the APS20B Control Module and plug the 4-PIN white connector into the mating 4-PIN connector.

Wire Color

Function

Polarity

Red

Lock

Ground (-)

Red

Unlock

Positive (+)

Green

Lock

Positive (+)

Green

Unlock

Ground (-)

Содержание Prestige APS-20B

Страница 1: ... 12 Volt Negative Ground Electrical Systems Only Kit Contents APS 20B Control Module 2 Three Button Transmitters 3 Channel Code Learning Receiver 1 Multi Pin Input Output Harness 1 Two Pin Door Lock Harness 1 Two Pin LED Indicator 1 Two Pin Valet Programming Switch Multi tone Siren 1 Installation Manual 1 Operator s Manual 1 Limited Warranty 2 Window Decals ...

Страница 2: ...8 drill bit then mount the siren using 8 sheet metal screws VALET PROGRAM MANUALOVERRIDESWITCH Since much of the use of this switch by the vehicle operator requires concurrent operation of the ignition key switch it is recommended that the Valet Program Manual Override Switch be placed such that it can be reached by the driver s left hand while they operate the ignition key switch with their right...

Страница 3: ...OFF and ACCESSORY positions Locate an ignition power wire at the vehicle s ignition switch harness Splice and tape the YELLOW wire of the system to this point WHITE Wire Positive Parking Light Flash Wire This wire is designed to provide a 12VDC positive light flash output driven by the APS20B s internal relay to be connected directly to the vehicle s positive parking light circuit Once the feedpoi...

Страница 4: ... ensure reliable system operation Special care must be taken to locate a clean metal part of the chassis as an attachment point for this wire Some installers prefer to locate a sturdy metal bolt under the dashboard or at the kick panel and use it as the attachment point If you find a suitable factory bolt that reads ground when tested attach a insulated ring terminal connector to the Black wire re...

Страница 5: ...ck output providing a positive pulse during the disarming sequence Connect the Green wire to the low current positive 12VDC factory door Lock signal wire leading from the factory switch to the factory door lock relay Connect the Red wire to the low current positive 12VDC factory door Unlock signal wire leading from the factory switch to the factory door unlock relay 4 WIRE POLARITYREVERSALand 5 WI...

Страница 6: ...he Ignition Switch and the Valet Program Manual Override Switch in a particular sequence This sequence is very time dependent in other words it must be performed quickly in order for you to enter the mode This sequence is also only one step different from the Transmitter Programming Mode so make certain you perform the sequence properly Upon entering the Programming Mode the system is immediately ...

Страница 7: ... chirps auto unlock off or Fourth Turn the valet switch on the off 1 chirp passive lock 4 flash pause Press transmitter Lock button to change 2 chirps active locks or Fifth Turn the valet switch on the off 1 chirp chirps on 5 flash pause Press transmitter Lock button to change 2 chirps chirps off or Turn ignition key off Exit program mode NOTE Once you enter the feature programming mode do not all...

Страница 8: ... 2003 Audiovox Electronics Corporation 128 6187B ...

Отзывы: