TABLE FOR THE CHOICE OF THE INJECTORS
Cat:
II
2H3+
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
G 30 - 28-30 mbar
G 31 - 37 mbar
G 20 - 20 mbar
Ø injectors
[1/100 mm]
Ø injectors
[1/100 mm]
Auxiliary (A)
1,00
0,30
50
72 (X)
Semirapid (SR)
1,75
0,45
65
97 (Z)
Triple ring (TR)
3,30
1,50
91
124 (Y)
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Triple-ring (TR)
6,60
Fig. 5.2
J
J
Fig. 5.3
INJECTORS REPLACEMENT OF HOB
BURNERS
This appliance is manufactured for
conversion to LPG. To purchase an
LPG conversion kit telephone acces-
sories direct 0870 6052020.
The diameter is marked on the injector
in cents of millimetre.
Select the injectors to be replaced
according to the “Table for the choice of
the injectors”.
To replace the injectors:
• Remove pan-supports and burners
from the hobtop.
• By a spanner, remove the injector “J”
(fig. 5.2-5.3) from its housing and
replace it by the proper one according
to the kind of gas (see following “Table
for the choice of the injectors”).
The burners are conceived in such a
way so as not to require the regulation
of the primary air.
CONVERSION TO LPG