d) Use an extinguisher only if:
1) You know you have a class ABC extinguisher and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
INSTALLATION INSTRUCTIONS
NOTE: THE DESIRED INSTALLATION HEIGHT OF THE HOOD IS AT THE DISCRETION OF
THE USER, HOWEVER, A HEIGHT OF 30” TO 36” ABOVE THE COOKING SURFACE
IS RECOMMENDED. TWO PERSONS ARE REQUIRED TO INSTALL HOOD.
BEFORE INSTALLING YOUR INSERT, BE SURE TO READ THE FOLLOWING!
*Either an interior, in-line, or remote blower may be used with Prestige hood liners and power packs.
Other blowers CANNOT be substituted. Select the series best suited for your application. Units la
-
beled “LINERS” are for use with in-line blowers or remote blowers. Units labeled “POWER PACKS”,
come with pre-installed 600 (S1) or 1200 (S2) CFM blowers. Before installing ANY unit, inspect and
test blowers to ensure there is no packing or obstructions remaining in the unit and that the blower(s)
spin freely.
PARTS SOLD SEPARATELY
- In-line blowers IL600, IL1000, IL1200, and IL1600
- Remote blowers RB1000, RB1200, RB1600, RB2000
- Transitions TR6x15/8RD, TR6x15/10RD (for use with S2 blower system), TRC8/6 transitions collar
(for use with S1 blower system.)
- Wall Caps WC6HD, WC8HD, WC10HD. The WC6x15/HD is for use with the S2 blower system
when rear ducting.
- Roof Caps RC6 sn RC10 will accommodate 6” to 10” round duct sizes.
- Backdraft damper BD8 or BD10 (in-line 8” or 10” section duct with backdraft damper installed).
- Wall switch kit UIBWSK controls both lights and fan(s) in lieu of unit switches.
NOTE: DURING INSTALLATION, PROTECT COUNTERTOP AND/OR COOKING APPLIANCES.
- 2 -