d) Use an extinguisher only if:

1) You know you have a class ABC extinguisher and you already know how to operate it. 

2) The fire is small and contained in the area where it started.

3) The fire department is being called.

4) You can fight the fire with your back to an exit. 

INSTALLATION INSTRUCTIONS

NOTE: THE DESIRED INSTALLATION HEIGHT OF THE HOOD IS AT THE DISCRETION OF

 THE USER, HOWEVER, A HEIGHT OF 30” TO 36” ABOVE THE COOKING SURFACE

 IS RECOMMENDED. TWO PERSONS ARE REQUIRED TO INSTALL HOOD.

BEFORE INSTALLING YOUR INSERT, BE SURE TO READ THE FOLLOWING!

*Either an interior, in-line, or remote blower may be used with Prestige hood liners and power packs. 

Other blowers CANNOT be substituted. Select the series best suited for your application. Units la

-

beled “LINERS” are for use with in-line blowers or remote blowers. Units labeled “POWER PACKS”, 

come with pre-installed 600 (S1) or 1200 (S2) CFM blowers. Before installing ANY unit, inspect and 

test blowers to ensure there is no packing or obstructions remaining in the unit and that the blower(s) 

spin freely. 

PARTS SOLD SEPARATELY 

- In-line blowers IL600, IL1000, IL1200, and IL1600

- Remote blowers RB1000, RB1200, RB1600, RB2000

- Transitions TR6x15/8RD, TR6x15/10RD (for use with S2 blower system), TRC8/6 transitions collar 

(for use with S1 blower system.)

- Wall Caps WC6HD, WC8HD, WC10HD. The WC6x15/HD is for use with the S2 blower system 

when rear ducting.

- Roof Caps RC6 sn RC10 will accommodate 6” to 10” round duct sizes. 

- Backdraft damper BD8 or BD10 (in-line 8” or 10” section duct with backdraft damper installed).

- Wall switch kit UIBWSK controls both lights and fan(s) in lieu of unit switches. 

NOTE: DURING INSTALLATION, PROTECT COUNTERTOP AND/OR COOKING APPLIANCES.

- 2 -

Содержание Power Pack Hood Liner

Страница 1: ...ower Pack Hood Liner Intended for Domestic Cooking Only READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with homeowner Homeowner Use and Care Information inside Prestige America 103 Fairf...

Страница 2: ...Hood Operating Instructions 3 Cleaning Instructions 4 Cleaning the Hood Surface 4 Rear Ducting Instructions 5 Warranty Information 5 Hood Insert Specs 0 S UIM Models 6 8 PRESTIGE PRODUCTS DIVISION Si...

Страница 3: ...DUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings boil overs can cause smoking and may ignite Heat oils slowly on low heat b Always turn hood ON when coo...

Страница 4: ...la beled LINERS are for use with in line blowers or remote blowers Units labeled POWER PACKS come with pre installed 600 S1 or 1200 S2 CFM blowers Before installing ANY unit inspect and test blowers t...

Страница 5: ...you leave adequate clearance for the stainless steel trim overlay and body of hood liner Cut along your marked line 3 Caution SWITCH OFF POWER AT SERVICE PANEL Insert 115 volt line though the 7 8 hole...

Страница 6: ...let each filter dry before replacing TO CLEAN HOOD SURFACE Do not use abrasive products For general care wipe the outside of the stainless steel with sudsy water or household cleaners Rinse well and d...

Страница 7: ...ring the one 1 year warranty period This applies to the actual parts and normal labor and excludes all other costs removal and re installation Items NOT covered in the warranty include light bulbs ite...

Страница 8: ...5 8 45 1 4 x 16 5 8 57 3 4 x 16 5 8 57 1 4 x 16 5 8 Transition Size INCLUDED INCLUDED INCLUDED TR6x15 8 or 10 TR6x15 8 or 10 TR6x15 8 or 10 TR6x15 8 or 10 TR6x15 8 or 10 TR6x15 8 or 10 Additional Info...

Страница 9: ...3 4 3 4 N A N A N A Cutout Dimension 25 3 4 x 13 5 8 31 3 4 x 13 5 8 37 3 4 x 13 5 8 45 1 4 x 16 5 8 51 1 4 x 16 5 8 57 1 4 x 16 5 8 Transition Size 10 Round Starter Collar 10 Round Starter Collar 10...

Страница 10: ...ize 6 Round TRC8 6 6 Round TRC8 6 TR6x15 8 or TR6x15 10 Hood Insert Specifications Guide UIM Models Front View Front View Front View Side View All UIM Models UIM 28 S2 UIM 28 S1 UIM 20 1 2 S1 5 11 1 2...

Отзывы: