1 Chirp

2 Chirp

3 Chirp

4 Chirp

5 Chirp

6 Chirp

1 Lock / Unlock Func

on

500ms

3.5sec

500ms L, DBL UL

DBL L, 500ms UL

DBL L, DBL UL

500ms L, 350ms UL

2 Igni

on Lock

OFF

ON

3 Igni

on Unlock

OFF

Unlock All

Unlock Driver

4 Exterior Illumina

on

OFF

With Arm

With Disarm

With Arm & Disarm

5 Auto Relock

OFF

Auto Lock

Auto Lock & Arm

6 Auto Arming

OFF

Auto Arm

Auto Lock & Arm

7 No

�fi

ca

on Sound

Both

Siren

Horn

8 Horn Timing

16ms

30ms

40ms

50ms

10ms

9 Valet Override Method

Valet

Custom Code

10 Driver Priority Unlock

OFF

ON

11 Silent Choice

OFF

From Transmi

er

OEM Style

12 Park Light / Trunk Swap

NA

13 AUX Ch. 4

Pulse

Push & Hold

10sec

20sec

Latch On/O

Hold 3/s for O/P

14 AUX Ch. 5

Pulse

Push & Hold

10sec

20sec

Latch On/O

Hold 3/s for O/P

15 Alarm Trigger Length

30sec

45sec

60sec

90sec

120sec

16 Dome Light Delay Timer

O

 / Program

15sec

30sec

45sec

60sec

120sec

17 Security Pro

le

All On

Doors O

Hood/trunk O

All O

All On w/ OEM RS

18 Data Port Protocol

ADS

DBI

Feature Bank 2

Op

ons

Fe

at

ur

es

1 Shock

2 Trunk/Hood

3 Door

The Feature Bank below can also be programmed using the FlashLogic Weblink.

Please visit www.FlashLogic.com for more detail.

Alarm

When the alarm is triggered the system will provide feedback to the 

user. Upon disarm, the system will beep four (4) times and flash the 

LED to indicate the Alarm Trigger Zone.

Important Update

The default Data Port Protocol of this system is ADS. If using an FLCAN or other external integration module be sure to choose iDatalink 

2-Way when flashing.

This system will also support DBI. This will require programming Feature Bank 2, Feature 18 to DBI.  

Notes

For Complete Installation Guide and Technical Support 

Please Visit

www.voxxuniversity.com

Or Call

1-800-225-6074

REV. B

2020 Voxx Electronics. All Rights Reserved.

Feature Programming

Remote Programming

Dome Delay Programming

Shock Sensor

The APS510Z includes two (2) programmed remotes. If required, 

additional remotes can be programmed to the system. Remote 

Programming is located in Feature Bank 1. To enter Remote Auto 

Programming:
1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. System will chirp 

and flash the parking lights one (1) time. 

Press the lock button on each remote. The system will beep one (1) 

time to indicate the remote has been programmed. Only primary 

remote functions are auto programmed. This Includes Lock, Unlock, and 

Trunk/Start.
If using AUX output control, the remote channel must be manually 

programmed to the system AUX output. Please see the complete 

installation guide for manual remote programming instruction.

The APS510Z Feature Bank can be programmed by using the valet 

button and remote. To enter Feature Bank programming:

1. 

Turn the ignition key to ON.

2. 

Press and release the valet button three (3) times. System will 

chirp and flash lights one (1) time for Feature Bank 1, Remote 

Programming.

3. 

Cycle ignition key OFF/ON. System will chirp and flash lights two (2) 

times for Feature Bank 2.

4. 

Press valet button to cycle features. LED will flash to display feature 

number.

5. 

Press lock button to cycle options. System will chirp to indicate 

option number.

To exit Programming cycle ignition key OFF and wait ten (10) seconds. 

The System will also automatically exit programming after sixty (60) 

seconds of no activity.

The shock sensor should be mounted to a solid surface in the center of 

the vehicle. Once mounted the shock sensor will require adjustment.

To increase sensitivity: Turn adjustment dial clockwise.

To decrease sensitivity: Turn adjustment dial counter clockwise.

To test sensitivity, strike the vehicle with an open palm. Adjust the dial 

to provide coverage to as much of the vehicle as possible.

This system can be programmed to ignore the vehicle’s theater dimming 

dome light. This feature will be used when connecting the door trigger 

input to the dome light circuit for alarm trigger. Note: Vehicle windows 

should be open to prevent accidental locking of keys in the vehicle.

Start with all doors closed and the vehicle dome light off.

1.  Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light 

solid.

2.  Open and close the driver door.
The system will monitor the dome light circuit. When the dome light 

turns off the system will set the delay time and add an additional two 

(2) seconds.

Dome Delay Reset

1. Key ON/OFF, ON/OFF, ON/OFF.

2. Press and hold valet button for five (5) seconds.
The system will chirp one (1) time to indicate reset is complete.

Data Protocol Selection 

The default data port protocol of this model is ADS (iDatalink 2-Way). 

This model is capable of detecting the correct data port protocol (ADS 

or DBI) and automatically configuring Feature Bank 2; Feature 18. To 

initialize the detection procedure:

1. 

Press and hold the valet button.

2. 

Cycle the vehicle’s Ignition ON/OFF two (2) times.

3. 

Release the valet button. 

The system will automatically detect and set the correct data port 

protocol, ADS or DBI.

Note

: This feature is only available on module firmware v2.00 or higher.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without 

entering the Feature Bank programming.

1. 

Turn the ignition key ON/OFF.

2. 

Press and release the valet button three (3) times.

The system will respond with one (1) chirp for ON and two (2) Chirps 

for OFF. This feature will not affect alarm trigger or programming. 

User Programmable LED

System LED notifications can be turned ON or OFF without entering 

Feature Bank programming.

1. 

Turn the ignition key ON/OFF, ON/OFF.

2. 

Press and hold valet button for five (5) seconds.

The LED will flash one (1) time for ON, two (2) times for OFF. This 

feature will not affect LED flash during programming.