APS
510Z
Security with Keyless Entry
Quick Installation Guide
1 Chirp
2 Chirp
3 Chirp
4 Chirp
5 Chirp
6 Chirp
1 Lock / Unlock Func
�
on
500ms
3.5sec
500ms L, DBL UL
DBL L, 500ms UL
DBL L, DBL UL
500ms L, 350ms UL
2 Igni
�
on Lock
OFF
ON
3 Igni
�
on Unlock
OFF
Unlock All
Unlock Driver
4 Exterior Illumina
�
on
OFF
With Arm
With Disarm
With Arm & Disarm
5 Auto Relock
OFF
Auto Lock
Auto Lock & Arm
6 Auto Arming
OFF
Auto Arm
Auto Lock & Arm
7 No
�fi
ca
�
on Sound
Both
Siren
Horn
8 Horn Timing
16ms
30ms
40ms
50ms
10ms
9 Valet Override Method
Valet
Custom Code
10 Driver Priority Unlock
OFF
ON
11 Silent Choice
OFF
From Transmi
�
er
OEM Style
12 Park Light / Trunk Swap
NA
13 AUX Ch. 4
Pulse
Push & Hold
10sec
20sec
Latch On/O
ff
Hold 3/s for O/P
14 AUX Ch. 5
Pulse
Push & Hold
10sec
20sec
Latch On/O
ff
Hold 3/s for O/P
15 Alarm Trigger Length
30sec
45sec
60sec
90sec
120sec
16 Dome Light Delay Timer
O
ff
/ Program
15sec
30sec
45sec
60sec
120sec
17 Security Pro
fi
le
All On
Doors O
ff
Hood/trunk O
ff
All O
ff
All On w/ OEM RS
18 Data Port Protocol
ADS
DBI
Feature Bank 2
Op
�
ons
Fe
at
ur
es
1 Shock
2 Trunk/Hood
3 Door
The Feature Bank below can also be programmed using the FlashLogic Weblink.
Please visit www.FlashLogic.com for more detail.
Alarm
When the alarm is triggered the system will provide feedback to the
user. Upon disarm, the system will beep four (4) times and flash the
LED to indicate the Alarm Trigger Zone.
Important Update
The default Data Port Protocol of this system is ADS. If using an FLCAN or other external integration module be sure to choose iDatalink
2-Way when flashing.
This system will also support DBI. This will require programming Feature Bank 2, Feature 18 to DBI.
Notes
For Complete Installation Guide and Technical Support
Please Visit
www.voxxuniversity.com
Or Call
1-800-225-6074
REV. B
2020 Voxx Electronics. All Rights Reserved.
Feature Programming
Remote Programming
Dome Delay Programming
Shock Sensor
The APS510Z includes two (2) programmed remotes. If required,
additional remotes can be programmed to the system. Remote
Programming is located in Feature Bank 1. To enter Remote Auto
Programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. System will chirp
and flash the parking lights one (1) time.
Press the lock button on each remote. The system will beep one (1)
time to indicate the remote has been programmed. Only primary
remote functions are auto programmed. This Includes Lock, Unlock, and
Trunk/Start.
If using AUX output control, the remote channel must be manually
programmed to the system AUX output. Please see the complete
installation guide for manual remote programming instruction.
The APS510Z Feature Bank can be programmed by using the valet
button and remote. To enter Feature Bank programming:
1.
Turn the ignition key to ON.
2.
Press and release the valet button three (3) times. System will
chirp and flash lights one (1) time for Feature Bank 1, Remote
Programming.
3.
Cycle ignition key OFF/ON. System will chirp and flash lights two (2)
times for Feature Bank 2.
4.
Press valet button to cycle features. LED will flash to display feature
number.
5.
Press lock button to cycle options. System will chirp to indicate
option number.
To exit Programming cycle ignition key OFF and wait ten (10) seconds.
The System will also automatically exit programming after sixty (60)
seconds of no activity.
The shock sensor should be mounted to a solid surface in the center of
the vehicle. Once mounted the shock sensor will require adjustment.
To increase sensitivity: Turn adjustment dial clockwise.
To decrease sensitivity: Turn adjustment dial counter clockwise.
To test sensitivity, strike the vehicle with an open palm. Adjust the dial
to provide coverage to as much of the vehicle as possible.
This system can be programmed to ignore the vehicle’s theater dimming
dome light. This feature will be used when connecting the door trigger
input to the dome light circuit for alarm trigger. Note: Vehicle windows
should be open to prevent accidental locking of keys in the vehicle.
Start with all doors closed and the vehicle dome light off.
1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light
solid.
2. Open and close the driver door.
The system will monitor the dome light circuit. When the dome light
turns off the system will set the delay time and add an additional two
(2) seconds.
Dome Delay Reset
1. Key ON/OFF, ON/OFF, ON/OFF.
2. Press and hold valet button for five (5) seconds.
The system will chirp one (1) time to indicate reset is complete.
Data Protocol Selection
The default data port protocol of this model is ADS (iDatalink 2-Way).
This model is capable of detecting the correct data port protocol (ADS
or DBI) and automatically configuring Feature Bank 2; Feature 18. To
initialize the detection procedure:
1.
Press and hold the valet button.
2.
Cycle the vehicle’s Ignition ON/OFF two (2) times.
3.
Release the valet button.
The system will automatically detect and set the correct data port
protocol, ADS or DBI.
Note
: This feature is only available on module firmware v2.00 or higher.
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without
entering the Feature Bank programming.
1.
Turn the ignition key ON/OFF.
2.
Press and release the valet button three (3) times.
The system will respond with one (1) chirp for ON and two (2) Chirps
for OFF. This feature will not affect alarm trigger or programming.
User Programmable LED
System LED notifications can be turned ON or OFF without entering
Feature Bank programming.
1.
Turn the ignition key ON/OFF, ON/OFF.
2.
Press and hold valet button for five (5) seconds.
The LED will flash one (1) time for ON, two (2) times for OFF. This
feature will not affect LED flash during programming.