Action

System Response

Turn ignition on

No  response

Press and release the valet switch 3 times

1 Chirp - LED 1 flash

Within 3 seconds, turn ignition Off, On, Off, On

Short chirp, then 2 long chirps

This Action Accesses Feature Bank 3 Remote Start Selectable Features

First

Press the valet switch one time

1 chirp = defrost output pulsed

Press transmitter Lock button to change

2 chirps = defrost output 10 Mins

o r

Second

Press and release the valet switch

2 chirps = RF start chirp on

Press transmitter Lock button to change

1 chirp = RF start chirp off

o r

Third

Press  and release the valet switch

2 chirps = run time set for 10 mins

Press transmitter Lock button to change

3 chirps = run time set fro 15 mins

Press transmitter Lock button to change

4 chirps = run time set for 20 mins

Press transmitter Lock button to change

1 chirp = run time set for 5 mins

o r

Fourth

Press and release the valet switch

1 chirp = parking lights on steady w/RS active

Press transmitter Lock button to change

2 chirps = parking lights flashing w/RS active

o r

Fifth

Press and release the valet switch

2 chirps = tachometer input checking

Press transmitter Lock button to change

1 chirp = voltage sense input checking

o r

Sixth

Press and release the valet switch

1 chirp = greater than 0.5 V check before start

Press transmitter Lock button to change

2 chirps = less than 0.5 V check before start

o r

Seventh

Press and release the valet switch

2 chirps = ign 2 on during crank

Press transmitter Lock button to change

3 chirps = ign 2 same as accessory

Press transmitter Lock button to change

1 chirp = ign 2 off during crank

o r

Eighth

Press and release the valet switch

2 chirps = ign 3 on during crank

Press transmitter Lock button to change

3 chirps = ign 3 same as accessory

Press transmitter Lock button to change

1 chirp = ign 3 off during crank

o r

Ninth

Press and release the valet switch

1 chirp = diagnostics off

Press transmitter Lock button to change

2 chirps = diagnostics on

o r

Tenth

Press and release the valet switch

2 chirps = crank time 1.0 sec

Press transmitter Lock button to change

3 chirps = crank time 1.5 sec

Press transmitter Lock button to change

4 chirps = crank time 2.0 sec

Press transmitter Lock button to change

1 chirp = crank time 0.8 sec

o r

Eleventh

Press and release the valet switch

1 chirp = unit set for gasoline engine

Press transmitter Lock button to change

2 chirps = unit set for diesel engine 10 sec delay

Press transmitter Lock button to change

3 chirps = unit set for diesel engine 15 sec delay

Press transmitter Lock button to change

4 chirps = unit set for diesel engine 20 sec delay

o r

Twelfth

Press and release the valet switch

1 chirp = transponder output while R/S active

Press transmitter Lock button to change

2 chirps = transponder output during start only

Press transmitter Lock button to change

3 chirps = transponder output until ignition turned off

o r

Thirteenth

Press and release the valet switch

Non Functional On This Unit

o r

Fourteenth

Press  and release the valet switch

1 chirp = crank averaging w/voltage input checking

Press transmitter Lock button to change

2 chirps = preset crank time w/voltage input check

o r

Fifteenth

Press and release the valet switch

Non Functional On This Unit

o r

Sixteenth

Press and release the valet switch

Non Functional On This Unit

o r

Seventeenth

Press and release the valet switch

1 chirp = aux o/p Black/Blue single pulse

Press transmitter Lock button to change

2 chirps = aux o/p Black/Blue as alarm feature #1

Press and release the valet switch or turn the ignition off to:

Exit Programming Mode

Note :

 Once you enter the feature programming mode, do not allow more than 15 seconds to pass between steps or the

programming will be terminated.

Содержание APS-901

Страница 1: ...RF Programmable Features Bank 2 Is Alarm Selectable Features Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps 1st DoorL UL 1 Sec 3 5 Sec 1 Sec L Dbl U L Dbl L 1 Sec UL Dbl L Dbl...

Страница 2: ...fth Press and release the valet switch Non Functional On This Unit or Sixth Press and release the valet switch Non Functional On This Unit or Seventh Press and release the valet switch Non Functional...

Страница 3: ...th Temp Start Not Available 14th Crank Averaging Averaging Preset Time Note When averaging the engine must be started 4 times with the key to be effective 15th R S Shock Not Available 16th Turbo Selec...

Страница 4: ...sory Press transmitter Lock button to change 1 chirp ign 3 off during crank or Ninth Press and release the valet switch 1 chirp diagnostics off Press transmitter Lock button to change 2 chirps diagnos...

Страница 5: ...iring or fluid lines Drill a 1 4 hole in the desired location and thread the hood pin switch into it using a 7 16 nut driver or deep well socket If using the mounting bracket first secure the bracket...

Страница 6: ...ND TO ADEQUATELY FUSE THE TWO POWER WIRES BASED ON THAT LOAD IF THE VEHICLE RUNNING UNDER LOAD WITH THE AIR CONDI TIONER HEATER BLOWER MOTOR ANDACCESSORIES EXCEEDS 24AMPS CONTINUOUS WE RECOMMEND THAT...

Страница 7: ...cations this wire must be connected to the ignition circuit that powers the glow plugs if the vehicle requires glow plug pre heating GREEN WIRE Ignition 2 Output Connect this wire to the ignition 2 wi...

Страница 8: ...eInhibitInput2 Any time the gray w black tracer wire is grounded the Remote Starter will stop operating even if the signal is received from the transmitter If the brake light switch in the vehicle swi...

Страница 9: ...running under control of the remote start unit 2 WHITE Wires Parking Light Flasher These wires are the COMMON and NORMALLY OPEN contacts of the on board parking lamp relay If the vehicle s parking lig...

Страница 10: ...o Do This 1 Measure the resistance of the resistor pellet on the ignition key then select a resistor within 5 of the key s value from the resistor pack supplied 2 Locate the pair of VATS wires in the...

Страница 11: ...e will provide a 1 second 300 mA pulsed ground output 1 5 second before the remote start unit activates as well as when the transmitter is used to disarm the system Typical use for this output would b...

Страница 12: ...vehicle the unit may not realize that the vehicle is running in certain instances and could re engage the starter motor The Remote Car Starter will learn the tach rate of most vehicles single ignitio...

Страница 13: ...f the Audiovox Remote Start Unit W A R N I N G DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE OPERATION OF THE HOOD PIN SAFETY SHUT DOWN FEATURE MANUALSHUTDOWN ENABLECIRCUIT The int...

Страница 14: ...w the key to be turned to the start position or be removed from the ignition cylinder This configuration prevents mechanical operation while the vehicle is in gear but offers no consideration for elec...

Страница 15: ...be fully explained to the consumer Circuits may be used only if the above circuit is not available METHOD 1 To connect to the key in sensor as shown in method 1 A Locate the control wire that connect...

Страница 16: ...ule If you are using anAudiovox Flash Logic module it can be connected directly to theAlarm Remote Start s control module Using the Blue 4 pin blue red black white harness and connect to the mating co...

Страница 17: ...128 7765 17 of 19...

Страница 18: ...128 7765 18 of 19 THISPAGELEFTBLANKINTENTIONALLY...

Страница 19: ...128 7765 19 of 19 2006 Audiovox Electronics Corp Hauppauge NY 11788 128 7765...

Отзывы: