Figure 2a
Figure 2b
Figure 2c
Figure 2d
Figure 3
Figure 4
Figure 5
Figure 6
Figure 1
FACE-SHIELD/LUNG BAG INSTALLATION
1.
Unlatch
the front torso skin of the Prestan Professional Infant
Manikin by unhooking skin from the ‘tabs’ located at the top of the
shoulders and peeling down the skin to expose the chest plate
(Figure 1).
2. Fold the Lung-Bag portion of the Face-Shield/Lung-Bag (Figures 2a-2d):
The Face-Shield/Lung-Bag has four ‘dotted lines’ printed on one
side of the bag (along with an oval)
Using the four dotted lines, fold the Face-Shield/Lung-Bag into fourths, following the diagram below
3. Tilt back the head of the manikin to open the airway.
4. Insert the folded Lung-Bag into the mouth of
the manikin (Figure 3).
5. Push the Lung-Bag into the mouth until the bag exits
through the neck of the manikin (Figure 4).
6. Grasp the Lung-Bag and finish pulling it through the
neck of the manikin (Figure 4).
7. Attach the Face-Shield tabs to the ‘buttons’ located
on the side of the manikin head (Figure 5).
8. Lightly pull down on the Lung-Bag to help open the
mouth hole on the Face-Shield.
9. Then position the Lung-Bag on top of the compression
plate (the hard plastic circular piece found on top of
the torso foam core) with the circular imprint on the
Lung-Bag aligning with the compression plate (Figure 6).
10. With proper positioning, the neck of the Face-Shield/
Lung-Bag will have slack. Make sure it is not twisted.
11. Roll the skin back up over the Lung-Bag being careful
not to press down and “fold” the skin. The torso may
then be closed by pushing on down on the shoulder
tabs until they snap into place.
First-Aid-Product.com - 760-944-1048