Pressure Tech LF-301 SERIES Скачать руководство пользователя страница 3


 

1. Description 

 
The  LF-301  provides  a  compact  and  economical  solution  for  controlling  pressures  up  to 
180bar on low flow applications. Ideal for first stage pressure let down where basic pressure 
control  is  required.  A  small  piston  sensing  element  allows  low  torque  adjustment  with  a 
range  of  springs  with  fine  pressure  adjustment.  The  unique  soft  seat  design  ensures 
particles flow over its surface, rather than perpendicular to it, which helps minimise damage 
from potential particles in the system. 
 
Pressure Equipment Directive (PED) 2014/68/EC Declaration 
This  equipment  is  designed  and  manufactured  in  accordance  with  Sound  Engineering 
Practice (SEP) Article 4, Paragraph 3 of the directive 2014/68/EC. As such, CE marking must 
not be applied. The equipment is marked under section 3.3 of Essential Safety Requirements 
of the directive. 
 

2. Installation 

 
Before system start-up, it is recommended that all systems be pressure tested, leak tested 
and purged with an inert gas such as nitrogen. 

 

Prior to placing into service ensure that the regulator is in the fully closed position, with the 
adjusting mechanism turned completely anti-clockwise. 
 
Check  the  model  number  reference  to  ensure  that  the  pressure  range  complies  with  the 
installation requirements.  
 
Visually  inspect  the  regulator  for  any  signs  of  damage  or  contamination.  If  any  foreign 
materials are present and cannot be removed from the regulator, or if the threads on the 
regulator appear to be damaged, please contact the office immediately to arrange for the 
regulator to be returned for service. 
 
The Inlet and Outlet ports are clearly marked. Select the correct size and type of connection 
fittings  for  these  ports  which  are  indicated  in  the  regulators  part  number.  Both  British 
Standard  Pipe  (BSPP)  ‘B’  and  National  Pipe  Thread  (NPT)  ‘N’  options  are  available  on  this 
regulator. Use the correct dowty or bonded seal for BSPP connections, self centering seals 
are  recommended.  For  NPT  threads,  ensure  that  PTFE  tape  is  applied  correctly  to  the 
fittings, applying two overlapping layers in the direction of the thread, taking care that the 
tape does not come into contact with the first thread. Any gauge ports on the regulator will 
be 1/4” NPT unless otherwise stated. If any gauge port is not required, ensure that the port 
is plugged prior to installation.  
 
The  media  supplied  to  the  regulator  must  be  clean.  Contamination  can  damage  the  seat 
which may cause the regulator to fail. Filtration suited to the application is recommended 
upstream of the regulator. Should further assistance or information be required in relation 
to installation of any Pressure Tech regulator please contact the office, giving reference to 
the regulators part number and/or serial number. 

 

Содержание LF-301 SERIES

Страница 1: ...1 THE LF 301 SERIES Operating and Service Manual Series includes all variants of LF 301 311 and CYL 301 311 Issue B January 2016...

Страница 2: ...e LF 301 5 6 1 1 Accessing the Main Valve Assembly 5 6 1 2 Adjusting the Set Point 6 6 1 3 Figure 1 Sectional View of the LF 301 7 7 Technical Data 8 8 Warranty Statement 8 Annex A LF 310 311 Solid Di...

Страница 3: ...lly inspect the regulator for any signs of damage or contamination If any foreign materials are present and cannot be removed from the regulator or if the threads on the regulator appear to be damaged...

Страница 4: ...ly for use in potentially explosive atmospheres and as such an ignition hazard assessment has not been carried out on this product If the user should wish to use this product in such an environment wh...

Страница 5: ...Valve 2 21 and place into the Regulator Body 1 viii Replace Seat Nut 4 fitted with new 5x1 mm O ring 18 taking care not to damage its sealing face against the tip of the valve ix Replace the O rings...

Страница 6: ...e ball needle valve vii With the outlet pressure set screw the first Lock Nut 12 to the base of the Adjusting Screw 11 against the Bonnet 10 viii Position the Hand Wheel 23 onto the Lock Nut 12 Ensure...

Страница 7: ...ER 7 PT C 106 8mm SENSOR 8 PT C 017 UPPER SPRING REST 9 BALL 010 SS 316 10mm BALL BEARING 10 PT C 015 BONNET 11 PT C 019 003 ADJUSTING SCREW 12 PT C 020 LOCK NUT 13 PT C 104 PTFE BACK UP RING 14 PT C...

Страница 8: ...PEEK PTFE FEP Flow Capacity Cv 0 06 also available in 0 03 and 0 15 Leakage Gas Bubble tight Liquid Zero drops of water at max inlet Max Inlet Pressure determined by seat material and Cv of regulator...

Страница 9: ...ype main valve arrangement The LF 310 311 solid disk option allows for a Maximum Working Pressure of 300 Bar 4350 Psi or 414 bar 6000 Psi when fitted with a PEEK seat The LF 310 is capable of accurate...