4.    Technical data

Pump type

Hand pump  06 911 101 

Hand pump  06 911 115

Container volume max. (ml)

1000

1500

Filling volume max. (ml)

800

1200

Pumping fluids

acetone-based solvents, brake cleaners, ketones, isopropyl, 

alcohol, acetone, white spirit, aliphatic hydrocarbons, solvents

Colour of container

white, transparent

Temperature range (°C)

+5 / +30

Operating pressure max. (bar)

2,5

2,5

Height (mm)

290

325

Base surface area LxW (mm)

230 x 110

230 x 120

Weight (kg)

0,42

0,45

Nozzle

flat spray nozzle

Spray pattern

110 ° spray angle

Spraying quantity with spray jet (ml/min)

192

192

Spraying distance with spray jet (m)

0,8

0,8

Colour code

black

Materials
Container

HDPE (high density polyethylene)

Pump head

PA

Rod + springs

brass / stainless steel

Nozzle

PA

     

Tab. 4.1: Technical data

5.    Assembly

The SPRAYFIxx-solvent PLUS is delivered fully assembled.

6.    Commissioning 

Prior to commissioning, check the SPRAYFIxx for proper assembly and ensure that there is no apparent 

damage.

Take out the pump, pay attention to the maximum filling volume and fill the container.

Press the lever several times until the pump builds up pressure. 

The SPRAYFIxx-solvent PLUS is now ready for use.

7.    Care/maintenance

After use, empty the device. Never leave the spray fluid in the device. Unscrew the pump and empty the 
device. Use an appropriate agent to clean the device and rinse it with clean water.  

 

NOTE

Do not use hot water for flushing the device (max. 30 °C).

Do not use hard objects to clean the nozzle and do not blow it through with your 

mouth. It is better to use a hand brush or a tooth brush.

8.    Troubleshooting

All position numbers indicated in the following table relate to figure 11.-1, refer to chapter 11.

Malfunction

Cause

Remedy

Pressure is built up, but insufficient 

atomization

 Nozzle clogged (pos. 4)  

 Clean the nozzle

Sprayer builds up pressure

 Check valve (pos. 11) at the pump  

   pipe (pos. 12) is dirty

 Clean the check valve

Fluid escapes at the nozzle without 

lever actuation

 Seal (pos. 10) for rod (pos. 30) dirty 

   or defective

 Clean or replace seal

Содержание SPRAYFI Series

Страница 1: ...OPERATING INSTRUCTIONS AND SAFETY NOTES SPRAYFIxx solvent PLUS for acetone based and acetone free solvents 88 909 932 A401 GB...

Страница 2: ...______3 1 3 1 Structure of the safety notes ____________________________________________________________3 1 3 2 Hazard symbols______________________________________________________________________3 1...

Страница 3: ...provisions as well as all other binding rules regarding occupational safety accident prevention and environmental protection Wear appropriate protective clothing in accordance with the work to be don...

Страница 4: ...lycol EDTA natrium cumene sulfonate potassium cumene sulfonate non ionic surfactants Car1 brake cleaner n hexane benzene Weicon brake cleaner propane 2 ol acetone naphta CRC Brakleen brake cleaner nap...

Страница 5: ...AYFIxx for proper assembly and ensure that there is no apparent damage Take out the pump pay attention to the maximum filling volume and fill the container Press the lever several times until the pump...

Страница 6: ...ly qualified personnel is authorized to disassemble and dispose of the SPRAYFIxx solvent PLUS 10 Repair service The SPRAYFIxx solvent PLUS was developed and produced according to the highest quality s...

Страница 7: ...98 12 1 Pump pipe bottom part M18x1 5 mm 87 177 13 1 Flat seal 26 8x8x0 8 mm 87 150 14 1 Button 83 449 15 1 Half round head screw 4x25 mm 87 092 16 1 Pump rod O ring seat 87 184 17 1 Pump rod counterh...

Страница 8: ...Pressol Schmierger te GmbH Parkstra e 7 93167 Falkenstein Germany Tel 49 9462 17 0 Fax 49 9462 17 208 info pressol com www pressol com...

Отзывы: