4. Technical data
Pump type
Hand pump 06 911 101
Hand pump 06 911 115
Container volume max. (ml)
1000
1500
Filling volume max. (ml)
800
1200
Pumping fluids
acetone-based solvents, brake cleaners, ketones, isopropyl,
alcohol, acetone, white spirit, aliphatic hydrocarbons, solvents
Colour of container
white, transparent
Temperature range (°C)
+5 / +30
Operating pressure max. (bar)
2,5
2,5
Height (mm)
290
325
Base surface area LxW (mm)
230 x 110
230 x 120
Weight (kg)
0,42
0,45
Nozzle
flat spray nozzle
Spray pattern
110 ° spray angle
Spraying quantity with spray jet (ml/min)
192
192
Spraying distance with spray jet (m)
0,8
0,8
Colour code
black
Materials
Container
HDPE (high density polyethylene)
Pump head
PA
Rod + springs
brass / stainless steel
Nozzle
PA
Tab. 4.1: Technical data
5. Assembly
The SPRAYFIxx-solvent PLUS is delivered fully assembled.
6. Commissioning
■
■
Prior to commissioning, check the SPRAYFIxx for proper assembly and ensure that there is no apparent
damage.
■
■
Take out the pump, pay attention to the maximum filling volume and fill the container.
■
■
Press the lever several times until the pump builds up pressure.
The SPRAYFIxx-solvent PLUS is now ready for use.
7. Care/maintenance
After use, empty the device. Never leave the spray fluid in the device. Unscrew the pump and empty the
device. Use an appropriate agent to clean the device and rinse it with clean water.
NOTE
Do not use hot water for flushing the device (max. 30 °C).
Do not use hard objects to clean the nozzle and do not blow it through with your
mouth. It is better to use a hand brush or a tooth brush.
8. Troubleshooting
All position numbers indicated in the following table relate to figure 11.-1, refer to chapter 11.
Malfunction
Cause
Remedy
Pressure is built up, but insufficient
atomization
Nozzle clogged (pos. 4)
Clean the nozzle
Sprayer builds up pressure
Check valve (pos. 11) at the pump
pipe (pos. 12) is dirty
Clean the check valve
Fluid escapes at the nozzle without
lever actuation
Seal (pos. 10) for rod (pos. 30) dirty
or defective
Clean or replace seal