background image

4

G

 Operating instructions for Pneumatic grease pump 50:1

 Operating instructions for Pneumatic grease pump 50:1 

G

 

2.    General Safety Advice

2.1   Signs and symbols used in the safety instructions

The safety instructions used in these operating instructions are divided into various levels of hazard. 

Various levels of hazard are indicated in the instructions with the following keywords and pictograms:

Pictogram

Keyword

Consequences of failure to comply with the

safety instructions

Warning

Possible death or serious injury

Caution

Possible slight or not serious injury or material damage

In addition, a further instruction is used which gives general tips for handling the product.

Pictogram

Keyword

Meaning

Tip

Background information or tips about how to use the product

2.2   Information on safety at work

The grease pump has been designed and manufactured according to the health and safety requirements 
of the relevant EC guidelines.

Nevertheless, there can still be risks if the product is not set up or operated as stipulated.

Therefore, before using the grease pump, read these operating instructions and pass them on to other 
users of the pump.

When operating the grease pump, the local safety and accident prevention rules and regulations always 
apply, as well as the safety advice in the operating instructions.

Only approved PRESSOL maintenance personnel should open or repair pumps within the guarantee 
period.
Attention! The compressed air line must be disconnected and the discharge pistol actuated to ensure 
so the pump is depressurised before the pump unit is opened or inspected. For safety reasons the 
compressed air line should be disconnected when the pump is not in use otherwise the pump will remain 
pressurised.

Caution!
If the grease pump is incorrectly installed, or used for a purpose other than that 
originally intended for, it can result in personal injury or damage to equipment!

Before starting to use the grease pump, read through these operating instructions carefully and 
completely.

Содержание Pneumatic grease pump 50:1

Страница 1: ...03 591 A411 GB Pneumatic grease pump 50 1 and grease supply system ...

Страница 2: ..._____________________________________8 Troubleshooting 8 ______________________________________________________________________8 Repairs Service 9 _______________________________________________________________________9 EC Declaration of Conformity 10 _ __________________________________________________________9 Exploded view 11 _ ___________________________________________________________________...

Страница 3: ...ction greases from NLGI 0 to NLGI 2 from original barrels 1 5 Operational Area Requirements The grease pump is intended for use within a building The installation area must be selected such that correct operation is ensured To avoid unnecessary damage and to prolong the life expectancy of the pump we recommend that an air line combination filter regulator and lubricator is utilised to ensure that ...

Страница 4: ...elines Nevertheless there can still be risks if the product is not set up or operated as stipulated Therefore before using the grease pump read these operating instructions and pass them on to other users of the pump When operating the grease pump the local safety and accident prevention rules and regulations always apply as well as the safety advice in the operating instructions Only approved PRE...

Страница 5: ...n result in environmental damage Local and country rules and regulations relating to domestic water supplies and fuel storage must be obeyed Caution Overpressure may cause damages of grease gun head and its accessories Do not exceed the working pressure stated in chapter 1 3 We recommend the use of original accessories according to DIN 1283 only Caution Overpressure at the point of lubrication may...

Страница 6: ...ng accessories swivel joint high pressure grease control gun etc onto the pump exit Pos 5 1 The grease pump is now ready for operation 4 Preparing for Operation Caution Never work on a pump that is running Mount or remove attachments and accessories only when the pump is switched off Connect the compressed air connection Pos 5 2 of the grease pump with the air supply line The pump now starts to ru...

Страница 7: ... Pos 2 can be removed from the bottom of the container while using compressed air supply In order to achieve this blow compressed air above the hose under the follower plate by means of an air insufflate pistol Uninstall the grease pump the dustcover the stabilizing fixing brackets and the follower plate in contrary sequence as described under step 3 assembly Tip Do not place the pump with its pip...

Страница 8: ...rom the container Push the container several times on the floor Press down the follower plate and replace the pump into the container Operate the high pressure grease control gun and connect the compressed air Grease too stiff Use only grease until consistency grade NLGI 2 Do not use grease below temperature of 15 C Friction loss in the delivery hose Select if possible only short hoses and insert ...

Страница 9: ...made commercially available complies in its design and construction with the EU directives If a change has been made to the appliance and this has not been agreed with us this statement loses its validity Designation of the appliance Pneumatic grease pump 50 1 Appliance type Pneumatic pump Year built See identification plate Applicable EC Directives EU Directive Machines annex 1 89 392 EEC Directi...

Страница 10: ...leeve 87 209 15 Compression spring 87 215 16 O ring 87 223 17 Insert 87 206 18 Screw 87 220 19 Distributor repair kit 87 351 19 1 Clamp 87 214 19 2 Sliding disc 87 213 19 3 O ring 87 225 19 4 O ring 87 224 19 5 O ring 87 223 19 6 Distributor 87 204 20 Muffler 87 227 21 Retainer 87 207 22 Piston rod repair kit 87 352 22 1 O ring 03 262 22 2 Piston rod 87 205 22 3 Slider 87 208 22 4 Piston rod 02 84...

Страница 11: ...aring 03 304 29 Pressure piston 87 508 30 Locking nut 00 808 31 Threaded rod 87 509 32 O ring 87 521 33 Suction tube Length 229 mm 87 510 Length 291 mm 87 511 Length 429 mm 87 512 Length 529 mm 87 513 Length 829 mm 87 514 34 Adapter 87 507 35 Lip washer 87 522 36 Upper casing 87 506 37 Circlip 03 501 38 Lip washer 00 152 39 Valve cone 03 477 40 Valve body 87 505 41 Sieve 03 503 42 Circlip 03 328 4...

Страница 12: ...12 G Operating instructions for Pneumatic grease pump 50 1 24 ill 11 1 Exploded View of the Pneumatic grease pump ...

Страница 13: ...13 Operating instructions for Pneumatic grease pump 50 1 G ...

Страница 14: ...Pressol Schmiergeräte GmbH Parkstraße 7 93167 Falkenstein Germany Tel 49 9462 17 0 Fax 49 9462 17 208 info pressol com www pressol com ...

Отзывы: