![Pressol 13 004 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/pressol/13-004/13-004_operating-instructions-and-safety-notes_1598023005.webp)
5
B
4
2
3
1
2
Operating Instructions - Barrel pump for AdBlue®
GB
Barrel screw coupling
13 004/13 004 950: G 2“ m
13 004 960: G 2‘‘ f and M 56 x 4 m
Materials of parts in contact with liquid
Pump body
PP
Seals
FKM
Suction pipe
PP
5. Assembly
Check and prepare all parts before assembly.
■
■
Insert tube B in tube A (N° 1).
■
■
Insert the tube formed by A+B in the pump entry (N° 2).
■
■
Adjust the length of tube C to get the desired length. (N° 3).
■
■
The tubes B + C are fastened with a bolt (which comes with a seal).
6. Commissioning
■
■
Before starting up, check the pump for proper installation and visible damage.
■
■
Insert the tube in the barrel and fasten the pump on the barrel (N° 2).
■
■
Place the pump in the desired position and fasten it with a nut (N° 1).
■
■
Can also be used for pumping from canisters with adapter (17 095).
■
■
Insert the transparent tubing in the pump’s exit hole and secure it with the clamp (N° 3).
■
■
Raise and lower the handle quickly until the liquid starts to come out (N° 4)
■
■
Turn the venting cap counterclockwise to stop the flow of liquid.
Fig. 5.-1 Assembly example
Fig. 6.-1 Commissioning