background image

OVERVIEW  

6

 

1 . 2   F E A T U R E S  

The following is a summary of your DEQ 624’s features: 

?

 

24-Bit Digital Signal Processing.

   The 

DEQ 624 

utilizes

 

24-Bit resolution for accurate 

processing of analog signals.  

   

?

 

Dual 31 Band Equalizers.

 Each channel of the Graphic Equalizer section of the 

DEQ

 

624 

is 

comprised of 31 digital EQ encoders.  These  digital EQ encoders are centered in 1/3

rd

 octave 

increments from 20 

Hz

 to 20 

kHz

.  

?

 

Separate High Pass & Low Pass Filters for each channel.

  Each channel of the 

DEQ 624

 is 

provided separate High and Low Pass filters.  The Low Pass Filter is variable from 10 

kHz

 to 20 

kHz

.  The High Pass Filter is variable from 10 

Hz

 to 410 

Hz.

 

?

 

Expander.

  Both channels have separate Expanders with Ratio and Threshold controls for 

minimizing system noise. 

?

 

Limiter.

   Each channel of the DEQ 624 is equipped with a “Brick-wall” limiter 

(Ratio=Inf: 1)

 

with a Threshold control to provide protection from extreme transients.  This feature is designed to 
protect the system components and the listener.   

?

 

HI Q.

   Selecting HI Q alters the characteristics of the equalization of the DEQ 624.  The center 

frequency remains fixed for both Normal Q and HI Q; however, in HI Q the effect on adjacent 
frequencies is less pronounced.  Normal Q is 1/3rd octave bandwidth 

(Q=4.32)

 and Hi Q is1/8th 

octave bandwidth 

(Hi Q=11.54)

  

?

 

Range.  

The degree of control of the digital encoders in the DEQ 624 Graphic Equalizer section 

can be altered by engaging the Range control switch located in the Dynamics/Master control 
section.  A choice of +

?

 / 

? ?

 dB

?

 

? ??

 

?

 

? ??

 dB

?

 and 

? ??

 

?

 

? ??

 dB can be chosen by pressing the 

Range switch.  The selected Range is indicated by LED’s located at the extreme left side of the 
Graphic Equalizer section.  Changing the Range selection for a channel changes the range for all 
EQ encoders on a channel. 

?

 

Bypass.  

Engaging the Bypass switch routes the signal from input to output by way of a hard-wire 

bypass (On-board metering continues to  monitor processed signal; not bypassed signal). 

?

 

4 User-Programmable Presets.  

Four user-determined setups can be stored in the DEQ 624.  

This is accomplished by storing a “snapshot” of the settings of the various controls of the front 
panel

 

of the unit into one of the four preset

 

positions provided for this purpose.  A Store switch 

Содержание DEQ 624

Страница 1: ...DEQ 624 DigitalStereoGraphicEqualizer PlusDynamicsProcessing User s Manual...

Страница 2: ...DEQ 624 D I G I T A L S T E R E O E Q U A L I Z E R P L U S D Y N A M I C S P R O C E S S O R USERSMANUAL Version1 0 2001 PreSonus Audio Electronics Incorporated All rights reserved...

Страница 3: ......

Страница 4: ...reserves the right to change or improve the design of the product at any time without prior notice This warranty does not cover claims for damage due to abuse neglect alteration or attempted repair by...

Страница 5: ...eSonus factory in the U S in the original packaging or a replacement supplied by PreSonus with all transportation cost and full insurance paid each way by the purchaser or owner All remedies and the m...

Страница 6: ...namics Master Controls 9 Meters 9 Filters 10 Expander 11 Limiter 11 Gain 12 Bypass 12 Range 12 HI Q 13 Enabling Disabling HI Q 14 Channel A Master 15 AHC 16 Presets 16 Storing Recalling Presets 17 Sec...

Страница 7: ...ue your suggestions and your comments PreSonus Audio Electronics is committed to constant product improvement The best way for us to be successful in this endeavor is by listening to the experts on ou...

Страница 8: ...I Q alters the characteristics of the equalization of the DEQ 624 The center frequency remains fixed for both Normal Q and HI Q however in HI Q the effect on adjacent frequencies is less pronounced No...

Страница 9: ...tentional alteration of the unit s controls will have no effect on the Preset governing the signal being processed Entering a user created three switch code combination restores complete operation of...

Страница 10: ...f the DEQ 624 occupies the right side of the front panel and contains the Limiter Expander Filters Gain control HI Q switch Range switch Bypass Channel Master A AHC Program LED s Preset switch Store S...

Страница 11: ...meters contained in the Dynamics Master section These meters display the output of channels A and B respectively from 42dBu to 22dBu A peak hold function has been incorporated into the output meters...

Страница 12: ...ariable from 10Hz to 410 Hz The High Pass filter is always active Signals above the user selected frequency point go through i e pass unaffected The variable filter control can be rotated fully counte...

Страница 13: ...nsion to begin and by selecting a ratio which controls the amount of downward expansion T H R E S H O L D The Expander Threshold control is variable from dB to Off R A T I O The Ratio control is varia...

Страница 14: ...ntinues to monitor processor activity in Bypass mode Range Each channel has a Range switch for selecting the range of control for the graphic equalizer section s digital EQ encoders One of three LED s...

Страница 15: ...the Dynamics Master Control section This enables HI Q select deselect mode for Channel A and disables Channel B HI Q switch and the Preset switch Any HI Q Active LED s below any of the Channel A equa...

Страница 16: ...and the Store Security switch light goes OFF The 1 kHz EQ encoder is now in HI Q 4 Pressing the Channel A HI Q switch turns off both the HI Q switch light and the HI Q Active LED indicator beneath th...

Страница 17: ...ay be de activated by A Pressing the Store Security switch B Turning the HI Q mode off by pressing the HI Q switch 3 The HI Q non volatile memory is updated when the HI Q mode is switched OFF R E M E...

Страница 18: ...and AHC become ineffective in controlling the noise hum it is then necessary to turn AHC OFF for a few seconds so it can adapt to the new noise level and then be selected again by pressing the switch...

Страница 19: ...system set up you ve just completed is now stored in the Program 1 position and can be recalled by pressing Preset until the Program 1 LED comes ON Four separate set ups can be stored and recalled in...

Страница 20: ...itches Any combination of three switches while holding the Store Security switch locks the front panel U N L O C K I N G T H E D E Q 6 2 4 To unlock the DEQ 624 hold down the Store Security switch and...

Страница 21: ...r 12 24 dB Green RANGE LED Indicators per channel 31 HI Q Active LED indicators 2 4 B A C K P A N E L B A S I C L A Y O U T Both channels of the DEQ 624 XLR inputs and outputs TRS inputs and outputs a...

Страница 22: ...figured to use the voltage of the electrical current for the country of retail sale USA 115V WARNING Attempting to operate this unit at voltages for which this power supply was not designed will void...

Страница 23: ...arrier Strip Output Output Impedance 51 Output Connectors XLR 1 4 TRS Barrier Strip Metering Level Meters 20 Segment LED 42dBu to 22 dBu Gain reduction 10 Segment LED 0 5dB to 12 dB Power Supply Type...

Страница 24: ...CONTROLS CONNECTIO NS 22...

Отзывы: