STEP
CONDITION
ADJUSTMENT
REMARKS OF ADJUSTMENT
6
USB(EU)
Channel 20
TX mode
with modulation
0,4KHz&2,5KHz
(30mV RMS)
RT203
Adjust RT203 to reach
11Wpep ± 0,5W on the RF power
meter.
7
USB(EU)
Channel 20
TX mode
without modulation
RT206
Connect RF probe to TP 201.
Adjust RT 206 to minimum reading
on oscilloscope.
8
FM(EU)
Channel 20
TX mode
without modulation
RT204
Adjust RT204 to reach 3,8W ±
0,1W on the RF power meter.
9
AM(EU)
Channel 20
TX mode
1,25Khz 30mV
RT205
RT207
1-Set RT207 to CW
2-Adjust RT205 to 95%
3-Adjust RT207
90% ± 3% modulation
10
FM(EU)
Channel 20
TX mode
1,25Khz 30mV
RT301
Adjust RT301 to reach 1,9Khz ±
0,1Khz of deviation..
11
AM(RU)
Channel 20
TX mode
without modulation
RT208
Adjust RT208 to reach 8W ±
0,1W on the RF power meter.
12
FM(RU)
Channel 20
TX mode
without modulation
RT209
Adjust RT209 to reach 20W ±
0,1W on the RF power meter.
13
USB(RU)
Channel 20
TX mode
with modulation
0,4KHz&2,5KHz
(30mV RMS)
RT210
Adjust RT210 to reach
20Wpep ± 0,5W on the RF power
meter.
Содержание GRANT II PREMIUM
Страница 1: ...GRANT II PREMIUM SERVICE MANUAL...
Страница 11: ...TP 303 TP 302 TP 301 L 304 RT 302 L 307 L 305 L 306 ALIGNMENT VCO PLL...
Страница 16: ...ALIGNMENT RECEIVER TP 1 L 19 RT 1 RT 3 RT2...
Страница 17: ...GRANTII PREMIUM BLOC DIAGRAM...
Страница 19: ...GRANTII PREMIUM SCHEMATIC DIAGRAM...
Страница 20: ...ASC ASC IN ASC OUT RT 1 PRE...
Страница 22: ...PRE...
Страница 23: ...PRE...
Страница 24: ...PRE...
Страница 25: ...GRANTII PREMIUM COMPONENT LAYOUT...
Страница 26: ...PRE...
Страница 27: ...PRE...
Страница 28: ...PRE...
Страница 29: ...PRE...
Страница 30: ...GRANTII PREMIUM COMPONENTS LIST...