WATER TREATMENT

®

Automatic Water Filters

INSTALLATION FITTINg ASSEMBLIES

Installation fittings connect to the control valve or the 
bypass valve using nuts that only require hand tightening. 
Hand tight nut connections between control valve and 
installation fittings, control valve and bypass valve, and 
bypass valve and installation fittings allow for ease 
serviceability. Do not use a pipe wrench to tighten nuts 
on installation fittings. Hand tighten only.
Split ring retainer design holds the nut on and allows load 
to be spread over the entire nut surface area reducing the 
chance for leakage. The split ring design, incorporated 
into the installation fittings allows approximately 2 
degrees off axis alignment to the plumbing system. The 
installation fittings are designed to accommodate minor 
plumbing misalignments but are not designed to support 
the weight of a system or the plumbing.
When assembling the installation fitting package, 
connect the fitting to the plumbing system first and then 
attach the nut, split ring and o-ring. Heat from soldering 
or solvent cements may damage the nut, split ring or 
o-ring. Solder joints should be cool and solvent cements 
should be set before installing the nut, split ring and 
o-ring. Avoid getting primer and solvent cements on any 
part of the o-rings or split rings, bypass valve or control 
valve. Solvent cements and primers should be used in 
accordance with the manufacturer’s instructions.
Slip the nut onto the fitting first, then the split ring 
second and the o-ring last. hand tighten the nut. If the 
fitting is leaking, tightening the nut will not stop the 
leak. Remove the nut, remove the fitting, and check for 
damage or misalignment of the o-ring.
Do not use pipe dope or other sealant on threads. Teflon 
tape must be used on the threads of the 1” connection 
and on the threads for the drain line connection. Teflon 
tape is not necessary on the nut connection or caps 
because of o-ring seals.
Do not use Vaseline, oils or other unacceptable lubricants 
on o-rings. A silicon lubricant may be used on black 
o-rings.

ByPASS VALVE

The bypass valve easily connects to the control valve 
body using nuts that only require hand tightening. Hand 
tighten nut connections between control valve and 
fittings, control valve and bypass valve, and bypass valve 
and installation fittings allow for easy serviceability. The 
split ring retainer design holds the nut on and allows load 
to be spread over the entire nut surface area reducing the 
chance for leakage. The split ring design, incorporated 
into the bypass, allows approximately 2 degrees off axis 
alignment to the plumbing system. The bypass is designed 
to accommodate minor plumbing misalignments but is 
not designed to support the weight of a system or the 
plumbing.

Avoid getting primer and solvent cements on any part 
of the o-rings or split rings, bypass valve or control valve. 
Do not use pipe dope or other sealant on threads. Teflon 
tape is not necessary on the caps because of o-ring seals.
Do not use Vaseline, oil or other unacceptable lubricants 
on o-rings. A silicon lubricant may be used on black 
o-rings.

A.  gENERAL

1.  Shut off all water at main supply valve.
2.  Shut off the fuel supply to water heater.
3.  Open faucets (hot and cold) nearest pump or water 

meter to relieve pressure and drain system.

4.  Move filter into the installation position. Loosely 

attach all fittings to measure for bypass valve 
assembly (if used), or manual bypass valve.

5.  Level the unit. (Do Not use metal shims.)
6.  Cut the cold water supply line as required.
7.  Install the bypass valve assembly if used.

B.  PLANNINg INSTALLATION

1.  All installation procedures must conform to local 

plumbing, electrical and sanitation codes and 
ordinances.

2.  It is recommended that outside faucets for lawn 

service be on the hard water line, ahead of the filter, 
to conserve filtered water.

3.  If this isn’t practical, use the convenient integral 

bypass valve assembly.
CAUTION: The inlet water temperature MUST NOT 
exceed 120° F.

4.  Do not locate filter where ambient temperature 

drops below 40° F.

5.  Allow space around the filter for ease of servicing.
6.  The filter drain lines must never be solidly connected 

to the sewer line. (Always provide an air gap at the 
END of the drain line). Valve drain line must not be 
elevated over 5’ from the top of the filter on well 
systems, and not over 8’ on municipal water systems.

7.  Move the filter into position and connect to bypass 

assembly (if used). The integral manual bypass option 
is a connection which eliminates the need for a 
3-valve manifold. This makes installation easier and 
provides a more convenient method of bypassing.

8.  IMPORTANT: Be sure that the water inlet line is 

connected to the “inlet” side of the bypass valve or 
to the inlet fitting. (Bypass valve both inlet/outlet 
fittings are marked.) If water lines are reverse, (inlet/
outlet) filter mineral may be forced from the water 
filter into the household plumbing system. If this 

Содержание CBW10

Страница 1: ...0 CCF10D CBW20 CBW20D CCF20 CCF20D Service Flow 1 Cont GPM 3 3 5 5 Peak GPM 8 8 10 10 Pipe Size In Out Inches 1 1 1 1 Operating Pressure Range PSI 30 125 30 125 30 125 30 125 Max Operating Temperature...

Страница 2: ...ng If feedwater pressure is known to be above 125 psi it is strongly recommended that a pressure reducing valve be installed at this point Unfiltered water to Sprinklers and any dersired unfiltered fi...

Страница 3: ...viceability The split ring retainer design holds the nut on and allows load to be spread over the entire nut surface area reducing the chance for leakage The split ring design incorporated into the by...

Страница 4: ...supply valve completely 8 Plug control valve into a non switched 115v power source 9 Manually stage filter to the backwash position see service manual 10 Open inlet valve and allow the unit to fill S...

Страница 5: ...threaded plastic fittings NEVER use pipe dope as it will deteriorate the plastic fittings CHECK WATER PRESSURE Minimum water pressure required at the inlet of the filter is 20 psi IF PRESSURE IS OVER...

Страница 6: ...g cooling are to be treated by the Chemical Free filter a larger model filter MUST be selected to accommodate the higher flow rate demands 4 IMPORTANT Always use Teflon tape on threaded plastic fittin...

Страница 7: ...pply valve completely 8 Plug control valve into a non switched 115V power source 9 Manually stage filter to the backwash position see service manual 10 Open inlet valve and allow the unit to fill SLOW...

Страница 8: ...t to backwash at a time of low water usage An example of a time with low water usage is when a household is asleep If there is a demand for water when the system is backwashing untreated water will be...

Страница 9: ...l Operation The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this pos...

Страница 10: ...nter clockwise to remove Turn clockwise to install Item No Part No Description Qty 1 023406 Motor 1 2 023412 PC Board 1 3 023408 Piston Assy 1 4 023409 Seal Assy 1 5 023410 O Ring Kit 1 6 127001 Miner...

Страница 11: ...35516 Activated Carbon Bypass Valve Less Connectors 023328 Connectors 023329 Set of 2 IL1052 Air Inducer CCF10 Only 021708 IL1053 Item Description CBW10 CBW10D CBW20 CBW20D CCF10 CCF10D CCF20 CCF20D 1...

Страница 12: ...sition d Press SET HOUR and DOWN for 3 seconds or unplug power source jack black wire from the circuit board and plug back in to reset control valve e Motor not inserted fully to engage pinion motor w...

Отзывы: