   The following parts are included:  

 

    • Power Supply

    • Two (2) Germicidal Twin H Lamp (packed in lamp box)

    • One (1) Oxidation unit with lamp installed

    • Sixteen (16) Sheet Metal Screws

When installing and using this electrical equipment, basic safety precautions

should always be followed including the following:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2.

 Always be sure the unit is unplugged during installation or service procedures.

3.

 

The ultraviolet light produced by the UV lamp is harmful to your eyes.  Do not look directly at 

    the lamp.  Should it become necessary to view the lamp, use UV-protected sunglasses.

Lors de l’installation et de l’utilisation de cet équipement, des précautions devront être suivies.

1- Lire et suivre les étapes attentivement.

2- Assurez vous de toujours débrancher avant l installation ou le service.

3

Ne pas regarder la lampe directement avec les yeux. Si nécessaire de le faire, 

    veuillez porter les lunettes de soleil contre les rayons U.V.

IMPORTANT: SAFETY INSTRUCTIONS

Important: Instructions de securité

 • Four (4) Caution Labels

 • Strain Relief Connector

 • Alcohol Pad for Cleaning Lamps

 • Installation & Maintenance Instructions

MUV7-100TR

MultiVoltage UVC System

  

Installation & Maintenance

Instructions

UNPACKING THE UNIT

Each unit is shipped with the germicidal lamps placed in a box with protective packaging. When handling lamps take 

care to not touch the glass portion of the lamp with bare hands. Oils from the hands can cause “hot spots” which 

reduce lamp life. Handle by the end caps or use a soft cloth. If you accidentally touch a lamp, use the alcohol pad 

included or clean it using a soft cloth dampened with rubbing alcohol. The lamp is fragile and proper care must be 

taken when removing from packaging.

Содержание MUV7-100TR

Страница 1: ...rs d brancher avant l installation ou le service 3 Ne pas regarder la lampe directement avec les yeux Si n cessaire de le faire veuillez porter les lunettes de soleil contre les rayons U V IMPORTANT S...

Страница 2: ...or by pressing the lock release marked PRESS on the connector see photo B Remove two thumb nuts holding moisture resistant lamp socket to mounting plate and remove from the plate 2 Using the lamp moun...

Страница 3: ...replace ballast Note Standard off the shelf lamps are not compatible with this unit Use of improper lamps will void warranty WARRANTY RETURNS All electronic components carry a lifetime warranty to th...

Страница 4: ...ly power to the unit CLEANING THE OXIDATION UNIT LAMP Recommended interval 12 months 1 Disconnect power to the unit 2 Remove the two 11 32 keps nuts and remove cover Unplug the lamp connector from the...

Страница 5: ...wire to L1 white wire to L2 green wire to ground Be sure power cord is secured with included strain relief connector The unit must cycle with the furnace blower Wire unit to an EAC terminal or current...

Страница 6: ...oles with tin snips 3 Peel off the adhesive backing of the gasket on backside of mounting plate 4 Center mounting plate on hole 5 Use four self tapping screws provided to secure mounting plate on the...

Страница 7: ...clusion or limitation of incidental or consequential damages or limitation of the duration of an implied warranty so the above limitations or exclusions may not apply to the customer This Limited Warr...

Отзывы: