premiere XC-2000 Скачать руководство пользователя страница 5

 

4.1 Specifications 

 
 

 

Function/ Parameter 

Technical Data 

Environment of use 

 

Clean, dry and flat surface 

 

Stable work surface 

 

Altitude: 

 

Relative humidity:≤80% 

Ambient Temperature 

 

+5°C~-40°C 

Applicable Voltage 

 

AC110V 60Hz (or 220V 50Hz-220 Model 
Only) 

Setting Time Range 

 

1~60min 

Maximum RPM 

 

4000 r/min 

Maximum relative centrifugal 

force (RCF) 

 

1000 rpm- 112 RCF 

 

1500 rpm- 252 RCF 

 

2000 rpm- 447 RCF 

 

2500 rpm- 699 RCF 

 

3000 rpm- 1006 RCF 

 

3500 rpm- 1370 RCF 

 

4000 rpm- 1790 RCF 

Rotor length 

 

5 cm 

Radius 

 

10 cm 

Maximum capacity 

 

15mL x 6  

Noise (maximum speed) 

 

≤70dB 

Dimensions (machine) 

 

11 x 11.5 x 10 in. (28 x 29 x 25 cm.)  

Net Weight 

 

9 lbs 

Dimensions (package) 

 

12 x 12 x 11 in.  (32 x 32 x 28 cm.)  

Gross Weight 

 

11 lbs 

 

 

 

 

Содержание XC-2000

Страница 1: ...in the best results of this equipment Warning To prevent fire or shock hazard do not expose this unit to rain or moisture Unless labeled otherwise this equipment should be used with AC 110V 60Hz in th...

Страница 2: ...1 Table of Contents Section Table of Contents Page 1 Safety Page 2 Contents Accessories Page 3 Specifications Page 4 Notes of Operations Page 5 Control Panel Setup Page 6 Operations Page 7 Warranty Pa...

Страница 3: ...under the maximum speed when the density of the sample exceeds 1 2g cm the maximum speed of the rotor must be reduced accordingly When the centrifuge is running rotor is spinning Please keep an area o...

Страница 4: ...ne tube cushions 6pc 4 Fuse 1pc 4 AMP 5 Operating manual 1pc Upon receipt please examine the package if there s anything wrong please kindly contact your dealer promptly 3 2 Accessories If you need op...

Страница 5: ...ly Setting Time Range 1 60min Maximum RPM 4000 r min Maximum relative centrifugal force RCF 1000 rpm 112 RCF 1500 rpm 252 RCF 2000 rpm 447 RCF 2500 rpm 699 RCF 3000 rpm 1006 RCF 3500 rpm 1370 RCF 4000...

Страница 6: ...en lid and remove specimen tubes Use only with accessories provided or parts designed specifically for use with this model Do not use centrifuge when the door is open Make sure the specimen tubes are...

Страница 7: ...nate display between time speed On Off run stop 6 2 Setup 1 Open box and remove centrifuge from packaging 2 Place centrifuge onto flat surface 3 Open lid and remove foam packaging inside 4 Plug Power...

Страница 8: ...etting for speed is in RPM s Please select desired speed shown in RPM s by using the or arrow buttons until the display panel reads your desired settings Spinning Centrifuge 2 Insert the centrifuge tu...

Страница 9: ...air technicians or damage occurring in transit If you have questions concerning this product or warranty contact the dealer from whom it was purchased For warranty service product should be well packe...

Отзывы: