CLEANING

CAUTION:

Before attempting to clean and/or service this unit, always disconnect the

power supply cord from the electrical supply outlet. 

1)

DO NOT use gasoline, benezene, paint thinner, or any other chemicals to clean this unit, as these 

substances will damage/deform both plastic components and luster finish.

2)

Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause

deterioration of electrical components and wiring insulation.

3)

Use only a mild dish washing detergent, lukewarm water, and a soft cloth to wipe the exterior surface of the

unit and dry thoroughly.

STORAGE

When the dehumidifer is not being used for long time periods, please follow these instructions:

1)

Disconnect the power cord from the power supply.

2)

Empty the water tank and wipe (clean) thoroughly.

3)

Clean air filter thoroughly.

4)

Re-package the unit in the original carton.

5)

Store the unit upright in a dry location. 

Occasionally, you may encounter some problems that are of a minor nature and a service call may not be 

necessary. Use this troubleshooting guide to identify possible problems you may be experiencing. If the unit

continues to operate improperly, call your local Danby Service Depot or 

1-800-26-

(1-800-263-2629)

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

1)

Unit will not operate. 

• Check power cord connection.

• Check electrical outlet for blown fuse.

• Check if water tank is full (if yes, empty).

• Check water tank is properly installed.

2)

Dehumidifying capacity 

(moisture removal) low. 

• Air filter is dirty and/or blocked.

• Ambient (room) temperature too low (below 5°C/41°F).

• Poor air flow circulation/obstruction of front grill.

• Relative humidity in surrounding environment very low.

3)

Relative Humidity setting not

reached after long period of 

operation.

• Check all doors and windows are closed.

• Area/room is too large for the capacity of the 

dehumidifier.

9

Содержание 6009REE

Страница 1: ...clus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product PR CAUTION Veuillez lire attentivement les consignes de s curit et les directi...

Страница 2: ...ently moved from room to room within your home and set up in just minutes For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following informati...

Страница 3: ...ounding plug on the power cord should be plugged directly into a polarized three slot effectively grounded receptacle rated 110 120 V A C FOR YOUR SAFETY To reduce the risk of fire or explosion do not...

Страница 4: ...atures should be between 6 C 42 8 F 35 C 95 F It is important to remember the efficiency of a dehumidifier will be effected influenced by the rate at which new humid air moisture is allowed to infiltr...

Страница 5: ...nk is full bucket full light illuminates OPERATING INSTRUCTIONS 1 2 3 8 6 7 4 5 4 REMOTE CONTROL 9 1 3 2 4 5 1 Power Key On Off 2 Fan Speed Key High Low 3 On Off Timer Key In running mode Auto switch...

Страница 6: ...he Bucket Full light will illuminate The water tank should be carefully removed from the machine by sliding it outward from the front of the unit and it should be emptied When the empty tank is replac...

Страница 7: ...air DEHUMIDIFYING MODE SELECTION 1 To turn the unit on press the ON OFF button 2 Press the humidity or buttons to select a desired RH operating value 30 90 FAN SPEED SELECTION Select a fan speed on th...

Страница 8: ...se Bucket 1 To save having to periodically empty the water tank this unit can be configured for continuous drain You can use the supplied drain hose to connect to the continuous drain connector 2 Unsc...

Страница 9: ...t on uneven ground to avoid shaking noise and water leakage 4 Always keep the unit 20cm or more from the wall to dissipate heat properly 5 DO NOT drop anything into the machine 6 Close all windows to...

Страница 10: ...Clean air filter thoroughly 4 Re package the unit in the original carton 5 Store the unit upright in a dry location Occasionally you may encounter some problems that are of a minor nature and a servic...

Страница 11: ...authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legislat...

Страница 12: ...e nous vous sugg rons de joindre une copie de votre re u de caisse et ou facture d achat cette page et d inscrire les renseignements suivants qui sont trouv s sur la plaque d identification du fabric...

Страница 13: ...tement sur une prise de courant polaris e de m me configuration et reli e la terre con u pour les circuits 110 120 V CA POUR VOTRE S CURIT Pour minimiser tout risque d incendie ou d explosion ne jamai...

Страница 14: ...et 35 C Il est important de noter que l efficacit d un d shumidificateur sera influenc e par la taux de r introduction d air humide dans la pi ce Pour obtenir la meilleure efficacit il convient de fa...

Страница 15: ...lumineux de seau plein d allume CONSIGNESD OP RATION 14 1 2 3 8 6 7 4 5 9 T LECOMMANDE 1 3 2 4 5 1 Bouton d Alimentation Marche Arr t 2 Touche de vitesse du ventilateur Haut Bas 3 Touche de la minuter...

Страница 16: ...yant lumineux Seau plein va s allumer Le r servoir d eau doit tre correctement enlev de l appareil en le glissant vers l ext rieur partir du devant de l appareil et il devrait tre vid Lorsque le r ser...

Страница 17: ...La vitesse que vous choisissez est identifi e par le voyant de signalisation lumineux situ directement au dessus du choix fait FILTRE AIR Le d shumidificateur comporte un filtre air amovible situ l av...

Страница 18: ...re configur pour le drainage continu Vous pouvez utiliser le tuyau de drainage fourni pour connecter sur le connecteur de drainage continu 2 D vissez et enlevez le bouchon du drain l arri re de l appa...

Страница 19: ...appareil sur un plancher in gal pour viter le tremblement le bruit et les fuites d eau 4 Toujours garder l appareil 20 cm ou plus d un mur afin de dissiper la chaleur correctement 5 Ne laissez rien to...

Страница 20: ...ement le filtre air 4 Remettre l appareil dans son emballage d origine 5 Remiser l appareil verticalement en un lieu sec Quelques probl mes mineurs peuvent occasionellement survenir que l utilisation...

Страница 21: ...repr sentations en vertu de toute loi r gissant la vente de produits ou de toute autre l gislation ou r glement semblables En vertu de la pr sente Danby ne peut tre tenue responsable en cas de blessu...

Страница 22: ...FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description D SHUMIDIFICATEUR PORTATIF Le num ro de mod le se...

Отзывы: