RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Depending on incoming feed water conditions replacement time frame may vary.

Change Time  

Description 

 

6 months:  

Sediment Pre-fi lter (104017);  Carbon Pre-fi lters (101009) 

12 months 

Final Carbon fi lter (100017)

This system has been tested according to NSF/ANSI 58 for reduction of the substances below.  The concentration of the indicated substances in 
water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specifi ed in 
NSF/ANSI 58.  This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) 
at concentrations of 0.30 mg/L or less.   This system reduces pentavalent arsenic, but may not remove other forms of arsenic.  This system is to 
be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to 
contain only pentavalent arsenic.  Treatment with chloramine (combined chlorine) is not suffi cient to ensure complete conversion of trivalent arsenic 
to pentavalent arsenic.  Please see the Arsenic Facts section of the installation manual for further information.

 

Avg. In. 

Avg. Eff. 

% Reduction  pH 

Pressure 

Max Eff. 

Inf. challenge 

Max Allowable

 

   

 

 

 

concentration 

concentration

 

   

 

 

 

mg/L mg/L

Arsenic (Pentavalent)  334.615 ug/L 

5.0385 ug/L 

98.4% 

 

50psi 

19 ug/L 

   0.30±10% 

0.010

Barium Reduction 

10.2 mg/L 

0.207 mg/L 

97.9% 

7.24 

50psi 

0.3 mg/L 

   10.0±10% 

 2.0

Cadmium Reduction 

0.036 mg/L 

0.0005 mg/L 

98.6% 

7.49 

50psi 

0.0007 

    0.3±10% 

0005

Chromium (Hexavalent)  0.15 mg/L 

0.013 mg/L 

91.3% 

7.24 

50psi 

0.03 

    0.3±10% 

0.1

Chromium (Trivalent) 

0.17 mg/L 

.01 mg/L 

94.1% 

7.24 

50psi 

0.01 

    0.03±10% 

0.1

Copper Reduction 

3.1 mg/L 

0.03 mg/L 

99.0% 

7.64 

50psi 

0.04 

    3.0±10% 

1.3

Cysts 

222,077#/ml 

10 #/ml 

99.99% 

 

 

58      minimum 50,000/mL   

Fluoride Reduction 

8.0 mg/L 

0.5 mg/L 

93.9% 

7.49 

50psi

 

0.7 

    8.0±10% 

1.5    

Lead Reduction 

0.15 mg/L 

0.002 mg/L 

98.6% 

7.49 

50psi 

0.003 

    0.15±10% 

0.010

Radium 226/228 

25 pCi/L 

5 pCi/L 

80.0% 

7.24 

50psi 

5 pCi/L 

    25pCiL±10% 

5 pCi/L

Selenium 

0.10 

0.008 

92.0% 

 

50psi 

0.011 

    0.10±10% 

0.05

TDS 

752 

27 

96.4% 

7.84 

50psi 

34 mg/L 

    750±40mg/L 

187

Turbidity 

10.2 mg/L 

0.26 mg/L 

97.5% 

 

 

0.83 

    11±1 NTU 

0.5 NTU

 

RECOVERY - 16.75% 

 

GALLONS - 24.8 GPD 

 

EFFICIENCY - 12.0%

Effi ciency rating means the percentage of the infl uent water to the system that is available to the user as reverse osmosis treated water under operating 
conditions that approximate typical daily usage.

 

Recovery rating means the percentage of the infl uent water to the membrane portion of the system that 

is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed. 

There is an average of 4 gallons of reject water for every 1 gallon of product water produced. Testing performed under standard laboratory conditions, 
actual performance may vary. Refer to owners manual for further maintenance requirements and warranty information.

Phone: (480) 675-7995 

 

Fax: (623) 866-5666 

 

Email: [email protected]

GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality.  Do not use 
with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.  Systems certifi ed for cyst 

reduction may be used on disinfected water that may contain fi lterable cysts.
2. Operating Temperature: 

 

 

Maximum: 100°F (40.5°C) 

 

 

Minimum: 40° (4.4°)

3. Operating Water Pressure:   

 

Maximum: 100 psi (7.0kg/cm2) 

 

Minimum: 40 psi (2.8kg/cm2)

4. 

pH 

    2 

to 

11

5. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
6. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.

Premier Inc.

 8716 W Ludlow Drive Suite #1

Peoria, AZ 85381

480) 675-7995   [email protected]

Performance Data Sheet

ZRO-4 Zero Waste RO

14

3 to 5 years  

R.O. Membrane (110009) 

Содержание ZRO-4

Страница 1: ...ameters may lead to the product s failure Save manual for future reference Model ZRO 4 ZERO WASTE REVERSE OSMOSIS SYSTEM Premier Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www PremierH2o com Fax 623 866 5666 199229 Manual Date 02 22 2016 System is in compliance with the Uniform Plumbing Code UPC International Plumbing Code IPC and IGC 159 2000A ...

Страница 2: ... alone Your system is a four stage RO which is based upon separate treatment segments within the one complete water filtration system These stages are as follows Stage 1 Sediment filter recommended change 6 months The first stage of your RO system is a five micron sediment filter that traps sediment and other particulate matter like dirt silt and rust which affect the taste and appearance of your ...

Страница 3: ...ill a Hole for the Faucet in a Porcelain Sink 5 Punch a Hole for the Faucet in a Stainless Steel Sink 5 Installation of Faucet 6 Connect Blue Tube from the RO to the Fuacet 6 Adapt a Valve Installation 7 Connect the Green and Black Tubing 7 Mounting the RO Module 7 Tank Ball Valve Installation 7 Blue Tube Connection From the RO Module to TANK 8 Start up Instructions 8 6 Month System Maintenance 9 ...

Страница 4: ...comply with State and local plumbing regulations This system is to be installed to treat cold water only Copper Tubing Reverse Osmosis water should not be run through copper tubing as the purity of the water will leach copper causing an objectional taste in water and pin holes may form in the tubing Premier supplies speciality filters part number 107008 that can be used if copper tubing follows th...

Страница 5: ...ep 5 The faucet can now be installed If mounting faucet to a Stainless Steel Sink you will need a 1 2 minimum hole punch The faucet opening should be centered between the back splash and the edge of the sink ideally on the same side as the vertical drain pipe Note Note Most sinks are pre drilled with 1 or 1 diameter hole that you can use for your RO faucet If you are already using it for a sprayer...

Страница 6: ...ghten brass nut securely Connect Blue Tube from the RO to the Faucet Step 9 Locate the blue 1 4 tube attached to the RO module labeled Faucet Remove a brass nut plastic sleeve and brass insert from the parts bag To assemble place the brass nut on the blue tube first then the sleeve small tapered end of sleeve must point to the end of tube and then push the brass insert all the way into the end of ...

Страница 7: ...ubing attached to the RO system Insert the open end of the green 1 4 tube into the open 1 4 quick connect fitting on the COLD water feed adapta a valve making sure the tube is pushed in all the way to the tube stop Repeat the procedure to connect black tubing from the RO module to the hot water return adapt a valve Mounting the RO Module Determine the best location for the RO Module to be mounted ...

Страница 8: ...drip Then close the faucet The tank will take approximately 4 hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal switch To test Unplug the garbage disposal and flip the garbage disposal switch to on If the RO pump turns on and water starts to drip ou...

Страница 9: ...d soap solution and rinse with water Check O rings and lubricate with water soluble lubricant KY Jelly or other water based lubricants may be used Petroleum based lubricants such as Vaseline must not be used Step 5 Before re installing the filter bowls back on to the system check O rings to make sure they are still in place Caution Insert a new sediment filter cloth like appearance into the 1st fi...

Страница 10: ...ressurize Turn on the RO faucet and let the water run for 30 seconds Turn off the RO faucet and let the unit rest for 2 minutes Finally open the RO faucet and let the water run for 5 more minutes Unplug the Power Transformer Turn off the incoming water supply to the system by turning the adapt a valve clockwise until it stops Keep the RO faucet open until the storage tank is completely drained Ope...

Страница 11: ...on Periodic inspection and following proper system maintenance is critical for continued performance Loosen Membrane Maintenance Use a 5 8 wrench to remove the Green Tube fitting on the left side of the horizontal membrane housing end with one elbow Step 1 Step 2 Step 3 Step 4 Step 5 Note Step 1 Turn off the incoming cold water supply to the RO at the adapt a valves and unplug the power transforme...

Страница 12: ...leaks at the top after Damaged Dry O ring Lubricate with water soluble lubricant or replace changing the filters O ring as necessary Do not use Vaseline or other petroleum based lubricants Pump constantly running Electrical fault Call for technical support Faucet left on Close faucet and let tank fill for 2 to 3 hours Plugged pre filters Replace filters 12 Once all water in the tank is purged chec...

Страница 13: ...rd Step 2 Lever will slide forward and completely off of the faucet base Step 3 Small brass tee can be turned 1 2 turn counterclockwise to adjust the tension on the black lever This adjustment may be necessary to stop slow drips from tip of faucet You may need to repeat the process until the faucet does not drip Brass tee must always end up facing across body of faucet in order to slide black leve...

Страница 14: ... mg L 0 5 mg L 93 9 7 49 50psi 0 7 8 0 10 1 5 Lead Reduction 0 15 mg L 0 002 mg L 98 6 7 49 50psi 0 003 0 15 10 0 010 Radium 226 228 25 pCi L 5 pCi L 80 0 7 24 50psi 5 pCi L 25pCiL 10 5 pCi L Selenium 0 10 0 008 92 0 50psi 0 011 0 10 10 0 05 TDS 752 27 96 4 7 84 50psi 34 mg L 750 40mg L 187 Turbidity 10 2 mg L 0 26 mg L 97 5 0 83 11 1 NTU 0 5 NTU RECOVERY 16 75 GALLONS 24 8 GPD EFFICIENCY 12 0 Eff...

Страница 15: ...t convert all the trivalent arsenic If you get your water from a public water utility contact the utility to find out if free chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove pentavalent arsenic It will not convert trivalent arsenic to pentavalent arsenic Under laboratory standard testing conditions this system reduced 0 30 mg L pp...

Страница 16: ...16 ...

Страница 17: ...10115 BLACK TUBING 1 4 X 3 1 2 45 610117 BLACK TUBING 1 4 X 4 46 610113 BLUE TUBING 1 4 X 4 47 610109 GREEN TUBING 1 4 X 4 Item Part Description 1 116023 FAUCET AG CHROME 2 134018 VALVE BALL PLAS ELB 4 119007 TANK PRESS 3 GAL WHITE 5 119028 TANK STAND 6 125017 CON PL 1 4C X 1 4M 7 100017 GAC IL 10 1 4F 8 125064 TEE MALE RUN 1 4 X 1 4 M 9 152032 SWITCH PRESSURE 60 PSI TSO 10 164010 CLIP DOUBLE MEM ...

Страница 18: ... Monitored 57 95 each 116093 Brushed Nickel Monitored 62 95 each Other Products from Premier Premier offers a filter change kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www PremierH2o com 1 4 inch connection kit includes 30 feet of 3 8 tubing ball valve and fittings Part No 500010 16 95 ea Premier Hot Water Recirculation System Bring convenience and savin...

Страница 19: ... Sediment Filter and a Carbon Block Filter Part No 560032 24 95 each Using only the available energy from the brine water otherwise lost to the drain the pump forces product water into the storage tank This process effectively reduces membrane back pressure to less than 5 psi and allows the membrane to maximize its use of the available feed pressure PERMEATE PUMP KIT For Standard RO Systems Non Ze...

Страница 20: ...ivel Ball Extension Triple Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray Soft Touch Adjustment Pads Anti Scaling Spray Nozzle High Strength Housing Triple Plated Finish Cartridge Life Rating 6 months Part No 107098 White Chrome 39 95 Part No 107080...

Страница 21: ... enter your information XXXXX XXXXXX Premier Inc is concerned for the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal information with other people or nonaffiliated companies We reserve the right to send you certain types of communications such as direct ma...

Страница 22: ... USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By SELF Plumbing Professional Where Purchased ____________ Model Number _______________________ Serial Number ____ __________ Iowa Department of Public Health Sales in Iowa require this to be completed s...

Страница 23: ...RVICE RECORD DATE OF PURCHASE DATE OF INSTALL INSTALLED BY SERIAL NO NAME Date of 6 mos 6 mos 1 yr 2 5 yrs OTHER Maintenance 1st stage 2nd stage Final Filter TFM Memb Sediment Carbon Block Carbon NOTES 23 ...

Страница 24: ...s per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This warranty does not cover any equipment that is relocated from the site of its original installation This warranty...

Отзывы: