Filter Shafts Fl-1 and Fl-2
DORW5030 - 24.02.2015
4.2 FI-2: Installation and removal of the filter insert for the stainless steel wedge-wire filter
Before use, remove any debris on/in the filter housing and inside the shaft, particularly in the hole
for the pipe socket.
1 Insert the filter housing (F2 D) with inflow pipe (F2 C) and calming inlet container (F2 B)
into the opening on the tank or shaft.
2 Place the bearing plane of the filter housing on the aluminium rail (F2 A3) in the filter
shaft.
3 Push the pipe socket on the filter housing into the hole in the filter shaft.
Once you have inserted it, check that it is secure and that there is no distortion.
Follow the sequence in reverse to remove.