6. Installation walk-on version

Excavation pit:

Care must be taken to avoid damage to existing pipework, vegetation or

buildings, when installing the MaxiPlus filter. The latter is especially important when there is a

deep installation of the MaxiPlus filter.

Filling material:

The filling material should be load-bearing, well compacted, frost free, ideally

this would be a wide-graded sand-/gravel mixture (e.g., grain size 0/32). Do not backfill with

material such as topsoil, rubble or clay soil. Excavated soil can only be used if it corresponds to

the above mentioned criteria.

Connection pipes

- it is very important that the outflow pipe has an incline equal to or greater

than the incline of the inflow pipe to the filter. Failure to observe this will cause the filter to back

up/overflow during heavy rainfall. This also applies to the auxiliary overflow.

Installing the Maxi Plus filter

1. Excavate the hole.
2. Lay a 100 mm thick bed of filling material,

compact it well (machine, or three operations with

hand tamper 15 kg / squared timber or similar)
3. Insert and adjust the filter, attaching the pipe

connections.

4. Fill in the filling material in about 100 mms

thick layers. The thickness of the filling material

around the filter body should be about 100 mms.

The rest of the layer can be filled with excavated

earth. Every layer has to be compacted, e.g. with

a hand tamper 15 kg / squared timber or similar

mechanical device.
This kind of filling should be carried out up to 100

mms from the top edge of the ground.

5. The rest filling can be chosen arbitrarily

A Filling material according to point 6

B Filling with excavation or similar

C upcoming ground

www.premiertechaqua.de

Technical changes and rights reserved. No liability for misprints

The contents of the technical documentation are a component of the guarantee terms

Planning and installation regulations are to be followed, as well as the accident prevention regulations.

Содержание Prefilter Maxi Plus

Страница 1: ...P edfiltr Maxi Plus N vod pro vestavbu a mont P edfiltr Maxi Plus Strana 2 6 Assembly instructions and mounting guide Prefilter Maxi Plus Page 7 11...

Страница 2: ...en P edfiltr Maxi Plus je dimenzov n podle DWA M 153 Technick vybaven filtru je ur eno pro maxim ln zat en zp soben v rozsahu odpov daj c m ploch m dvor parkovi t m pro osobn automobily a m lo frekven...

Страница 3: ...ako to p ek kou toku D ky sv velikosti tato tvo velk vstupn pr ez k odtoku v n m jsou rychlosti toku velmi n zk m je proces sedimentace pozitivn ovlivn n Usazov n ste ek leh ch ne voda je zv hodn no o...

Страница 4: ...odu e otev t kr tk m oto en m a na doraz a n sledn m vyta en m nahoru m je umo n na vizu ln kontrola ke zji t n mno stv ne istot odlou en ch ve filtru P ed odstran n m ne istot by m la b t filtra n pa...

Страница 5: ...n ch ne istot Jeho vymontov n prob hne po vymontov n vlo ky filtru B viz tak bod 4 vyta en m na lanu E Z chytn ko na list vpravo vymontov n A B C viz bod 2 5 2 P ipojen DN 110 P ipojen na veden ch DN1...

Страница 6: ...i siln m de ti p et kat nebo bude z filtru vyt kat m n dob e filtrovan voda Odtok vestavby 1 V kop stavebn j my 2 Vytvo en lo e ze z sypov ho materi lu o tlou ce cca 100 mm dob e zhutnit Strojem nebo...

Страница 7: ...according to DWA M 153 The technical equipment of the filter is designed for a maximum load such as courtyard surfaces passenger car parking areas and less used streets DWA A 138 chart 1 Points 1 to...

Страница 8: ...case D This settling process is improved by the retention time and design of the filter cartridge Settling of particles lighter than water is improved by the filter meshes in which only small particl...

Страница 9: ...n and servicing The cover can be very simply opened by turning and pulling up This allows you to check the amount of the debris produced in the filter Before removing any debris the filter cartridge h...

Страница 10: ...s It is taken out after removing the filter cartridge B see also point 4 by means of the withdrawal rope E leaf collecting basket on the right removed A B C see point 2 5 2 Connection to DN 110 The co...

Страница 11: ...e auxiliary overflow Installing the Maxi Plus filter 1 Excavate the hole 2 Lay a 100 mm thick bed of filling material compact it well machine or three operations with hand tamper 15 kg squared timber...

Страница 12: ...mky Notes Premier Tech Aqua GmbH Odborn telefonick poradenstv n mecky 49 0 38847 6239 0 www premiertechaqua de ptad premiertech com Premier Tech Aqua 12 12 Vorfilter prefilter Maxi Plus DORW2107 10 02...

Отзывы: