Premier Mounts INW-42 Скачать руководство пользователя страница 5

 

- 5 -

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Opening the wall structure  

NOTE: 

It is assumed that the room ambient air temperature and conditions where the INW-series is to be incorporated is suitable to maintain an acceptable 

operating temperature for the display. It should also be noted that due to the shear size and weight of the large screen display when attached to the base pan it 
will have a natural slight down tilt characteristic to about 3

°

. Raising the initial installation height of the pan or setting the base pan on a slight reverse angle will 

compensate for this. The mount that any display will protrude beyond a standard depth wall varies depending on the display chassis depth and rear ventilation 
path clearance requirements. 

INW50 Series 

 
  Prior to cutting, survey the wall that is to receive the plenum base pan to ensure the area to be cut into is free of obstructions such as cables, wire pipes etc. 
The base pan requires a wood frame or other suitable material to support a weight of at least 300 lbs. with a width opening of 52.875” minimum and a height 
opening of 36.750” minimum and a wood stud depth of 3.50” minimum. See figure 1. 

NOTE: The plenum base pan width of 52.750” is such that it will fit directly inside the first and forth 16.000” center wood stud in a standard framed 
wall if applicable in the location selection.  

INW42 Series 

 
  Prior to cutting, survey the wall that is to receive the plenum base pan to ensure the area to be cut into is free of obstructions such as cables, wire pipes etc. 
The base pan requires a wood frame or other suitable material to support a weight of at least 300 lbs. with a width opening of 46.375” minimum and a height 
opening of 34.062” minimum and a wood stud depth of 3.50” minimum. See figure 1. 

NOTE: The plenum base pan width of 46.38” is such that it will fit directly inside the first and forth 16.000” center wood stud in a standard framed wall 
if applicable in the location selection. 

Figure 1 

Wood stud frame  

Wood studs 

Wall structure 

INW60 Series 

 
  Prior to cutting, survey the wall that is to receive the plenum base pan to ensure the area to be cut into is free of obstructions such as cables, wire pipes etc. 
The base pan requires a wood frame or other suitable material to support a weight of at least 300 lbs. with a width opening of 64.250” minimum and a height 
opening of 44.750” minimum and a wood stud depth of 3.50” minimum. See figure 1. 

NOTE: The plenum base pan width of 64.00” is such that it will fit directly inside the first and forth 16.000” center wood stud in a standard framed wall 
if applicable in the location selection.  

Содержание INW-42

Страница 1: ...Inwall mount I N S T A L L A T I O N M A N U A L PREMIER MOUNTS 2004 REV 00 3130 E Miraloma Ave Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 www mounts com...

Страница 2: ...ations where there is vibration movement or danger of impact Failure to do so could result in display cracking or falling from the wall causing damage and injury Do not install near heater fireplace d...

Страница 3: ...Assembly drawing Wall structure Wood stud frame Mounting Bracket Sold separately Display not supplied Decorative bezel provided by customer Fan brackets 1 supplied with inwall In wall plenum box Air f...

Страница 4: ...sure that none of these parts are missing before beginning installation If there are parts missing stop the installation and contact Premier Mounts INW42 Plenum INW50 Plenum INW60 Plenum 4 6 32 Hex n...

Страница 5: ...directly inside the first and forth 16 000 center wood stud in a standard framed wall if applicable in the location selection INW42 Series Prior to cutting survey the wall that is to receive the plen...

Страница 6: ...le See figure 2 NOTE A standard handy box extension ring can mount directly to the inside of the pan at the knock out points to provide an A C power duplex outlet mounting point Step 3 Install the muf...

Страница 7: ...mounting points in the top of the base pan with the three 10 32 nuts supplied The fan supplied uses 110 volts A C current and comes with pig tail ends It is recommended the fan be wired to the same 11...