Premier Mounts CTM-MS1 Скачать руководство пользователя страница 2

CTM-MS1

Page 2 

Visit the Premier Mounts website at http://www.mounts.com

 

Installation Instructions

Contact Premier Mounts with any questions: 
(800) 368-9700
[email protected]

Contents

Warning Statements

Weight Limit

Maximum Flat Panel Weight: 

160 lb.

THE WALL STRUCTURE MUST BE CAPABLE OF 
SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF 
THE FLAT PANEL. IF NOT, THE WALL STRUCTURE MUST 
BE REINFORCED. 

 PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND 

COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION 

FOR FUTURE REFERENCE.

 PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED 

IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS 

PERSONAL INJURY, OR EVEN DEATH.

 SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE 

PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.

 PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS 

PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY 

UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS, 

DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR 

IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.

 

 At least two qualified people should perform the assembly procedure. Personal injury and/or property damage can result 

from dropping or mishandling the flat panel.

 

 If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs 

or ceiling studs. Use of an edge-to-edge stud finder is recommended.

 

 It is recommended that a maximum of ⅝˝ plaster board be used when mounting to wooden studs.

 

 Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there 

 

are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.

 

 Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a 

water or gas line may cause severe property damage or personal injury.

 

 This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious 

personal injury.

 

 Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of 

impact.

Weight Limit. ............................................................................................................................................................. 2

Warning Statements. ................................................................................................................................................ 2

Installation Tools. ...................................................................................................................................................... 3

Parts List................................................................................................................................................................... 3

Mounting Hardware. ................................................................................................................................................. 4

Nylon Spacers and Flat Washers.

 ............................................................................................................................ 4

Features. .................................................................................................................................................................. 5

Installing the Wall Plate. ........................................................................................................................................... 6

Introduction. ................................................................................................................................................. 6

Installing the Mounting Brackets.

.............................................................................................................................. 8

Selecting the Mounting Hardware. .............................................................................................................. 8

Griplate™ Washer Installation. .................................................................................................................... 9

Nylon Spacer Installation.

 ............................................................................................................................ 9

Attaching the Mounting Brackets to the Flat Panel.

 ................................................................................... 10

Mounting the Flat Panel.......................................................................................................................................... 10

Attaching the Flat Panel to the Wall Plate. ................................................................................................ 10

Safety Knurl Knob Installation.

 ............................................................................................................................... 11

Panelock™ Installation.

 .......................................................................................................................................... 11

Locking Safety Screw Installation.

 ............................................................................................................. 12

Tilt Adjustment.

 ....................................................................................................................................................... 12

Technical Specifications.

 ........................................................................................................................................ 13

Warranty.

 ................................................................................................................................................................ 14

Disclaimer ............................................................................................................................................................... 14

Содержание CTM-MS1

Страница 1: ...Phone 1 800 368 9700 Fax 1 800 832 4888 Other Locations Phone 001 714 632 7100 Fax 001 714 632 1044 EUROPE Unit 3 The Moorings Business Park Channel Way Longford Coventry CV6 6RH UK Phone 44 0 24 766...

Страница 2: ...re Personal injury and or property damage can result from dropping or mishandling the flat panel If mounting to wall studs or ceiling studs make sure that the mounting screws are anchored into the cen...

Страница 3: ...ed before beginning installation If there are parts missing and or damaged please stop the installation and contact Premier Mounts at 1 800 368 9700 CTM MS1 Tilting Wall Mount Assembly Components Wall...

Страница 4: ...5 x 16mm Combo Screw Qty 6 M5 x 20mm Combo Screw Qty 6 M5 x 25mm Combo Screw Qty 6 M6 x 12mm Combo Screw Qty 6 M6 x 20mm Combo Screw Qty 6 Nylon Spacers and Flat Washers You may stack the nylon spacer...

Страница 5: ...removed or dislodged from the wall plate Directional Mounting Arrow Lets you know which edge is the top Cable Electrical Cut Out Allows for easy cable access and power distribution installations Moun...

Страница 6: ...e a stud finder to determine the exact center of wall studs in the vicinity of the wall plate 2 Use a pencil to mark the exact center of each of the wall studs Step 1 Step 2 Step 3 Two people are reco...

Страница 7: ...5 mounting locations along the center of each wall stud Two people are recommended for this step one person to level the wall plate and another person to drill the pilot holes Drill a pilot hole in th...

Страница 8: ...eaded inserts to compare and verify their depth using the straw or toothpick s 1 8 allowance mark 5 Locate the correct diameter screw for the threaded insert If the screw you selected is longer than t...

Страница 9: ...Griplate washers installed at the bottom of the flat panel must have the points of the dimples facing towards the flat panel Does the flat panel have Recessed mounting points Uneven mounting points A...

Страница 10: ...r flat panel 4 Secure each mounting bracket to your flat panel by inserting a minimum of two 2 screws per bracket Do not overtighten the mounting hardware Attaching the Mounting Brackets to the Flat P...

Страница 11: ...knurl knobs and instead chose to use the Panelock skip this section and proceed to the Panelock Installation section below The Panelock is a theft deterrent device It comes with security hardware that...

Страница 12: ...usting the Flat Panel Friction Tilt Angle 1 Place one hand at the center top edge of the flat panel 2 Place the other hand on the center bottom edge of the flat panel 3 Using the upper hand gently pul...

Страница 13: ...CTM MS1 Installation Instructions Visit the Premier Mounts website at http www mounts com Page 13 Technical Specifications All measurements are in inches millimeters...

Страница 14: ...MOVING AND REPLACING DEFECTIVE PRODUCTS OR PARTS SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU W...