Prem-I-Air TJF120-LD012 Скачать руководство пользователя страница 2

OPERATION 

 
 

 
 

 
Fan Switch              
Low Speed Indicator 
High Speed Indicator 
Ioniser Switch and 
indicator 

 
1. 

Ensure filter is unpacked and installed before operation.  
(Refer to Installation Instructions Section). 

Best performance: 

We recommend that you operate your air cleaner 24 hours a day 
because indoor air can be quickly contaminated by activity in a 
room, for example outside air, smoking, and other air pollutants. 
While the air cleaner will not process all the air in a room, the 
more air circulated through your air purifier, the more filtered air 
returned to the room.  Portable air cleaners will be much more 
effective in rooms where all doors and windows are closed.  
However, for best performance the air outlet slot should be kept 
clear, at least 1 metre (three feet) in all directions. 
 
2. 

Insert the main’s plug into a suitable power socket, checking 
first that the household voltage matches the voltage stated 
on the product rating plate. 

3. 

Press the FAN button to turn your air cleaner ON. The fan 
will start at HIGH speed.  Press the FAN button again to 
select LOW speed.  To turn the air purifier OFF press the 
FAN button again. 

4. 

Press the IONISER button to turn on the IONIC purification 
mode, the IONISER light is now lit.  Press the IONISER 
button again to turn OFF this function.  REMEMBER you can 
use the IONIC purification mode with the fan OFF for silent 
filtration. 

 

IMPORTANT: if the Collector Plates are not refitted 
correctly your Air Purifier will not start.  If your Air 
Purifier fails to start check the fitting of the Collector 
Plates first. 

 

IMPORTANT: your IONIC Air Purifier produces a 
stream of ION charged air in order to silently filter all 
the air in your room.  If placed too closely to a TV or 
Radio it may cause some interference.  We 
recommend that your IONIC Air Purifier is placed at 
least 2 metres from a TV or Radio. 
 
 
 
 
 

MAIN FEATURES                   

1.  Purification function: 
This purifier is equipped with an odour filter system, which 
consists of an activated carbon filter.  This Air Purifier uses 
stainless steel collection plates in conjunction with ION generators 
to remove airborne pollutants and irritants from the air silently and 
without filters. The purification system can eliminate smoke and 
odours, absorb and decompose harmful bacteria in the air, thus 
reducing air pollution and

 

improving air quality in the home.  An 

ION generator draws air into your Air Purifier where it is further 
attracted to the stainless steel collector plates and the dust and 
particles are trapped.  Clean air is thus pushed out of your air 
purifier helping to create a circulation of air within your room. 
2.  Negative ion function: 
Negative ions are discharged to combine with dust, bacteria and 
mildew in the air, and remove them. 
3.  Fan Boost: 
You can use the fan boost to clear a room when you first start 
your Ionic air purifier, after a period of non use or to boost odour 
removal through the activated charcoal filter. 

 

PARTS DESCRIPTION 

 
 

Lift here to remove the 
Stainless Steel Collector Plates 

 

Stainless Steel Collector Plates 
Control Panel 
 
 
 
 
Activated Carbon Filter 

 
 
 

 
FILTER INSTALLATION AND 
MAINTENANCE 

Block

Filter frame

Body

 

Block

Filter frame

Body

 

                              

 

 

IMPORTANT:  Switch off and unplug your Air Purifier before 
removing the Filter. 

Unlock the Filter tray by pushing the lock button up. 
Using the finger recess, ease the filter tray from the main body. 
If you usually run your Air Purifier with the fan the filter can 
become dusty and may be gently cleaned with a vacuum cleaner 
hose attachment. The Charcoal Filter should be replaced every 9 
to 12 months or when you notice that the odour reducing effect 
has diminished.  For replacement filters contact our Help Desk on 
0870 742 5021 

 

COLLECTOR PLATE CLEANING 

  

                   

           

 

 

IMPORTANT:  Switch off and unplug your Air Purifier before 
removing the Collector Plates. 

Hold the handle on the top of your Air Purifier and pull the 
assembly upwards. 
Wipe the stainless steel plates clean with a soft dry cloth or a 
neutral detergent if necessary.  Ensure that the Collector Plates 
are dry before refitting and using your Air Purifier. 

NOTE: If you do not clean the Collector Plates regularly you 
will notice the occasional noise coming from your Ionic Air 
Purifier.  This is perfectly normal and will stop once the 
plates have been wiped clean. 

 

MAINTENANCE 

CAUTION: SWITCH OFF AND DISCONNECT 
FROM POWER SUPPLY BEFORE SERVICING 

1. 

To clean the unit use a soft cloth to wipe off any dust.  If the 
unit is very dirty use a damp cloth.  Do not use any cleaning 
detergents, sprays or any other chemicals as these will 
damage the unit.  Ensure no water enters into the machine. 

2. 

Replace the Charcoal Filter when you notice that the 
Charcoal Filter is no longer removing the smells or after 9 to 
12 months. 

3. 

Do not use your unit in areas where there is thick dust or 

smoke, as this will damage the filter. 

 

Отзывы: