ADJUSTING AIR FLOW DIRECTION

   Adjust the air flow direction 

correctly otherw

ise, it might 

   cause discomfort or  cause uneven room temperatures.
   Adjust the horizontal louver using the remote controller.
   Adjust the vertical louver manually.

Adjusting the Vertical Air Flow Direction (up - down)

The air conditioner automatically adjusts the vertical air 
flow direction in accordance with the operating mode.

To set the vertical air flow direction

Perform this function while the unit is in operation.
Keep pressing the AIR DIRECTION button on the remote 
controller to move the louver to the desired 

positio

n.

   Adjust the vertical air flow direction to the desired 

posit

tion.

   In subsequent operations, the vertical air flow is 
   automatically set in the direction to which you adjusted
   the louver by pressing the AIR DIRECTION button.

   

To set the horizontal air flow direction (left - right)

Adjust the vertical louver manually using the lever on the
 left or right side of the vertical louver arm (Depending on
 model). Take care not to catch fingers on the fan, horizontal
 louver or to damage vertical louvers. When the air
 conditioner is in operation and the horizontal louver is  in
 a specific position, move the lever at left (or right, depending
on model) end of the air outlet to the desired position.

To automatically swing the air flow direction (up - down)

Perform this function while the air conditioner is in operation.
    Press the SWING button on the remote controller.
    To stop the function, press the SWING button again.
    Press AIR DIRECTION button to lock louver in desired 
    position.

6

  ( C)

TEMP

AUTO 

COOL

DRY

HEAT

FAN

HIGH

MED

LOW

MODE

FAN SP

EED

TIMER O

N

SLEEP

ON/OFF

TIMER O

FF

        AIR

 

 DIRECT

ION

RESET LO

CK

SET TE

MPERA

TURE

        SWI

NG

        LED

    DISPL

AY

        TUR

BO

Lever

Содержание PMSF09 Series

Страница 1: ...e BD24 9RH Get In Touch Call 0845 6880112 Email info adremit co uk Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air...

Страница 2: ...air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service Contact an a...

Страница 3: ...tion It may cause electric shock or fire due to heat generation No earthing may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may...

Страница 4: ...ge may occur Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use...

Страница 5: ...e in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside th...

Страница 6: ...actual appearance of the air conditioner purchased 4 3 5 2 6 1 10 9 12 13 11 7 8 8 Indoor unit Outdoor unit 1 Front panel 2 Air inlet 3 Air filter 4 Air outlet 5 Horizontal air flow grille 6 Vertical...

Страница 7: ...Manual control button Panel AUTO COOL Open and lift the front panel up to an angle until it remains fixed with a clicking sound One press of the manual control button will lead to the forced AUTOoper...

Страница 8: ...vertical air flow is automatically set in the direction to which you adjusted the louver by pressing the AIR DIRECTION button To set the horizontal air flow direction left right Adjust the vertical lo...

Страница 9: ...power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION 7 AUTOMATIC OPERATION When you set the air conditioner in AUTO mode it will automatical...

Страница 10: ...he air conditioner and dis connect the power supply before cleaning WARNING MAINTENANCE Filter Handle Thinner 8 Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold...

Страница 11: ...and place filter into position 9 Electrostatic Filter Maintenance Checks before operation If you plan to idle the unit for a long time perform the following 1 Operate the fan for about half a day to d...

Страница 12: ...utlet on COOL mode in an indoor environment that has a high relative humidity A white mist maybe due to moisture generated from the defrosting process when the air conditioner restarts in HEAT mode op...

Страница 13: ...conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating d...

Страница 14: ...g out from the air conditioner Cause Power cut Unit may have become unplugged Fuse may have blown Battery in Remote controller may have been exhausted The time you have set with timer is incorrect Wai...

Страница 15: ...n d l u o h s s t c u d o r p l a c i r t c e l e e t s a W k c e h C t s i x e s e i t i l i c a f e r e h w e l c y c e r e s a e l P e t s a w d l o h e s u o h e c i v d a g n i l c y c e r r o f...

Отзывы: