OPERATIONS 

 

Operating the unit in COOL MODE:

 (

indicator illuminates) 

Press 

MODE

 button to select 

COOL.

 Press 

SPEED

 button to choose H, M or L fan 

speed. 

1.  Set your desired temperature by pressing 

U

 or 

V

 button. 

2.  The unit will continue to give cool air until the set temperature is reached. 

The lowest temperature for 

COOL

 mode is 18

O

C.

 If the current room temperature is 

higher than the temperature set on the remote control the compressor will be running and 

the unit will be delivering cooled air

 

3.  Once the room temperature has reached the temperature set on the remote the 

compressor will shut off leaving just the fan running. The unit will now be 

circulating room temperature air only.  

 
Operating the unit in DRY MODE:

 (

indicator illuminates) 

Press 

MODE

 button to select 

DRY

1.  Dry is a very gentle cooling operation. 

2.  Compressor activates to remove moisture from the room. 

3. While in 

DRY

 mode, the fan will only work in L speed. 

4. 

For best effect, do not mount the exhaust hose to the unit.

 

 

Operating the unit in AUTO MODE

: (

 indicator illuminates) 

  Press MODE button to select 

AUTO

  Choose H/M/L fan speed as you like by pressing 

SPEED

 button. 

  The product will deliver cooled air when room temperature is above 26

O

  The product will operate in 

DRY MODE 

when room temperature is between 23

O

to 26

 O

C. 

  The product will simply circulate room temperature air when temperature is 23

O

or below. 

 

Select FAN speed:  (

indicator illuminates) 

Choose H / M / L fan speed as you like by pressing 

SPEED 

button. 

(Remark: 

AUTO

 FAN mode only available in remote control. Fan speed is changing 

by system preset) 

 

Oscillation louvre

: (

 indicator illuminates) 

Press SWING button to turn the louvres swing left and right. 

 
Setting timer: (

 

indicator illuminates)

 

1.  Press TIMER button to set your desired running time. The timer indicator will 

illuminate to show the number of hours selected. When the running time has 
ended, the air conditioner will turn off automatically. The display window will show 
the hour(s) you set as you press TIMER button. If the timer button is not pressed, 
the unit will work continuously. 

2. 

By pressing the timer but without turning on the other functions, you can 

PRE-SET

 

the time for the machine to work. For example, if you press the timer to '2', the unit 
will work automatically after 2 hours.

 

3.  If you want to cancel timer function, press 

TIMER

 button again to turn the timer 

function off. 

Содержание PKY12

Страница 1: ...12000BTU Mobile Air Conditioner Model PKY12 Please read and retain these instructions for future reference...

Страница 2: ...omfort by adjusting the temperature and humidity in a room Its mobility makes it easy to use in various rooms To ensure the optimal efficiency of the air conditioner we advise you to keep doors and wi...

Страница 3: ...ds 13 DO NOT let chemical substances come into contact with the appliance 14 DO NOT use the appliance in the presence of flammable substances or such as alcohol insecticides petrol etc 15 DO NOT use t...

Страница 4: ...connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 Th...

Страница 5: ...HI AUTO h ON OFF CONT TIMER T EMP Drainage outlet Please transport this product in an upright position only and place the product on a stable level surface ACCESSORIES Indoor adaptor for insertion ov...

Страница 6: ...on a flat level surface at least 50cm from any objects DO NOT plug it in until exhaust hose is installed Installing the exhaust hose Use only the hose provided and clip exhaust hose and indoor adapto...

Страница 7: ...ways try to keep air filter clean To prevent conditioned air from escaping keep windows doors and any other openings closed CONTROL PANEL LED DISPLAY 1 Auto Mode Icon 2 Fan Speed 3 Cooling Mode 4 Swin...

Страница 8: ...n can be activated to the timed switching off mode only when the unit is switched ON Timer function can be activated to the timed switching on mode only when the appliance is turned off POWER Indicato...

Страница 9: ...M L fan speed as you like by pressing SPEED button The product will deliver cooled air when room temperature is above 26O C The product will operate in DRY MODE when room temperature is between 23O C...

Страница 10: ...tem to start operating again the water inside the unit required draining in one of the following ways 1 Turn off the air conditioner and unplug from the power socket While the reservoir is full avoid...

Страница 11: ...RFULL indicator flashing Is the room temperature below the set temperature The machine seems to have little cooling effect Is there direct sunshine Please close the curtains or blinds Are too many win...