GENERAL SAFETY REQUIREMENTS 

Domestic wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change 
of occupancy. For office and retail premises, and buildings such as village halls, the wiring must be inspected at least 
once every 5 years. It is recommended that all building be fitted with smoke alarms (it is mandatory for new 
buildings). 

TESTING 

When used in an office environment, we recommend that this product should be safety-tested yearly by a qualified 
electrician (PAT Tested). 
We recommend that it is PAT tested regularly when used in a domestic environment. 
If the mains lead is damaged, it must be replaced by the manufacturer or an authorised service centre. If the mains 
plug needs to be replaced, proceed as follows: 

 

Connect the brown wire to the terminal labelled “L”

 

Connect the blue wire to the terminal labelled “N”

 

Connect the green and yellow wire to the upper terminal labelled “E”

 

Make sure that the cord-grip is positioned correctly (over the outer sheath

of the cable) and it fully tightened.

 

If the plug is fitted with a fuse other than 13A, then please replace with an

approved fuse of the correct value.

OPERATING COSTS 

At time of going to press, the average cost of electricity is £0.15 per unit (kilowatt-hour). The amount you are being 
charged will be shown on your electricity bill. At this cost, the EH1908 will cost £2.29 per day to run on the “High 
Speed” setting. 

DISPOSAL AND RECYCLING 

You must not dispose of this appliance with domestic household waste. 

Most local authorities have specific collection system for appliances and disposal is free of charge to the end-user. 
When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for 
disposal. 

Содержание EH1908

Страница 1: ...EH1908 8 000BTU Mobile Portable Local Air Conditioner with Remote Control Timer and Wi Fi Please Retain for Future Reference Caution Risk of fire R290...

Страница 2: ...erials Do not place the mains lead beneath a carpet or rug Do not use this appliance in locations where paint petrol or other flammable liquids are used or stored Please ensure the appliance is switch...

Страница 3: ...reference please see the real product for detailed information warning This unit uses a flammable refrigerant If refrigerant leaks and comes in contact with fire or heating part there is risk of fire...

Страница 4: ...THE EXHAUST HOSE 1 Connect the hose connector to one end of the exhaust hose 2 Connect the windows adaptor kit to the other end of the exhaust hose Exhaust Hose Hose Connector Window Kit Adaptor Remot...

Страница 5: ...window to secure the kit in place It needs to hold the window kit firmly in place 5 Attach the hose connector to the exhaust air outlet of the unit 6 Adjusting the length of the flexible exhaust hose...

Страница 6: ...ng mode button 4 Add Increasing the desired temperature 16 32 or timer setting 5 Indicators LED for fan speed High Low and Wi Fi 6 Timer Sets a time for the unit to automatically start or stop 7 Fan S...

Страница 7: ...speed 2 4 To control the direction of the air flow please adjust the inner louver by hand Note The air conditioner stops if the room temperature is equal to the selected temperature 3 Ventilating you...

Страница 8: ...2 Press and hold the TIMER button for about 3 seconds the Wi Fi LED will flash rapidly 3 Launch the app and select 4 Select Air conditioner menu and follow the instructions on the app 5 Once the appli...

Страница 9: ...to empty the drainage tank in cooling operation except in exceptionally high humidity conditions The condensate water evaporates at the condenser and is evacuated through the exhaust hose For continuo...

Страница 10: ...h the filter in the opposite direction of air flow Set aside and allow the filter to air dry before reinstalling WARNING To prevent accidental injury from extreme temperatures and sharp edges do not t...

Страница 11: ...st hose is detached Make sure the exhaust hose is securely attached Water Leakage Overflow while moving the unit Empty the water tank before transport Check if the drain hose is kinked or bends Straig...

Страница 12: ...ct the brown wire to the terminal labelled L Connect the blue wire to the terminal labelled N Connect the green and yellow wire to the upper terminal labelled E Make sure that the cord grip is positio...

Страница 13: ...hts Our guarantee is administered by our retailers If your product arrives damaged you must contact the retailer from whom you bought it The retailer s contact details will be on the invoice that arri...

Отзывы: