AFV-P-T620 Series 620V Voltage Transform Unit
Installation
AFV-P-T620 can only be used with the AFV-P series. Turn the AFV-P series off before
installation. The power cord used must be rated at least 85
℃
and has sufficiently
gauge
,
so they will not overheat while carrying the output current. The input power
line must have a current rating which is greater than or equal to the maximum rated
current of the product.
Figure 1
Referring to Figure 1, perform the following steps:
1.
Remove the safety covers of the input and output terminal from the rear
panel of AFV-P-T620.
2.
Connect the input terminals of AFV-P-T620 to the output terminals of AFV-P.
The terminals SL, L,
, N, SN must be connected correspondingly.
3.
Fasten the power cords with strap.
4.
Connect the load to the N and L of the output terminals of AFV-P-T620, and
ensure to connect
to the ground.
5.
Screw the safety covers back to the input and output terminals.