Predator 69675 Скачать руководство пользователя страница 3

      Page 3

For Pump technical questions, please call 1-800-444-3353.

For engine technical questions, please call 1-800-520-0882.

Item 69675 / 69676        

Sa

Fet

Y

O

Pe

R

ati

O

n

m

aintenan

C

e

Setu

P

8. 

use only lubricants and fuel 

recommended in this manual.

9. 

improper connections to a building electrical 

system can allow electrical current from the 

generator to backfeed into the utility lines.

 Such 

backfeed may electrocute utility company workers 

or others who contact the lines during a power 

outage, and the generator may explode, burn, or 

cause fires when utility power is restored. Consult 

the utility company and a qualified electrician if 

intending to use the generator for back up power.

10. 

Do not operate the Generator before grounding. 

the Generator must be earth-grounded 

in accordance with all relevant electrical 

codes and standards before operation.

Operating Precautions

1. 

CaRBOn mOnOxiDe hazaRD 

using a generator indoors Can Kill 

YOu in minuteS. 

Generator exhaust contains carbon 

monoxide.  This is a poison you cannot 

see or smell. 

NEVER use inside a home or garage, EVEN IF doors 

and windows are open. 

Only use OUTSIDE and far away from windows, 

doors, and vents.

2. 

never use a generator indoors, including in 

garages, basements, crawl spaces and sheds.

 

Opening doors and windows or using fans will NOT 

prevent carbon monoxide build up in the home.

3. 

When using generators, keep them outdoors 

and far away from open doors, windows, 

and vents to avoid toxic levels of carbon 

monoxide from building up indoors.

4. 

if you start to feel sick, dizzy, or weak while 

using a generator, get to fresh air right away. 

The carbon monoxide from generators can 

quickly lead to full incapacitation and death.

5. 

Keep children away from the equipment, 

especially while it is operating. 

6. 

Keep all spectators at least six feet 

from the engine during operation.

7. 

Fire Hazard! Do not fill gas tank while engine 

is running. 

Do not operate if gasoline has been 

spilled. Clean spilled gasoline before starting engine. 

Do not operate near pilot light or open flame.

8. 

Do not touch engine during use. let engine 

cool down before service or storage.

 

9. 

Never store fuel or other flammable 

materials near the engine.

10. 

if the plugged in product operates abnormally 

or unusually slow, immediately stop using the 

generator as a power source.

  Always read and 

adhere to the instruction manual of the product 

to be powered, to make sure that it can be safely 

and efficiently powered by a portable generator.  

11. 

Before connecting an appliance or power 

cord to the generator:  make sure that it is in 

good working order. 

Faulty appliances or power 

cords can create a potential for electrical shock.

12. 

Do not exceed the maximum power rating of 

the generator.

 Make sure that the total electrical 

rating of the all of the tools or appliances plugged 

into the generator at the same time does not 

exceed that of the generator. Check that the startup 

surge will not be beyond the limit of the Generator. 

Power levels between rated and maximum 

may be used for no more than 30 minutes.

13. 

avoid substantially overloading which will 

trip the circuit breaker.

 Exceeding the time 

limit for maximum power operation or slightly 

overloading the generator may not switch the 

circuit breaker or circuit protector OFF, but will 

shorten the service life of the generator.

14. 

Do not attempt to connect or disconnect 

load connections while standing in 

water, or on wet or soggy ground.

15. 

Do not touch electrically energized parts of 

the Generator and interconnecting cables 

or conductors with any part of the body, or 

with any non-insulated conductive object.

Set up Precautions (cont.)

Содержание 69675

Страница 1: ......

Страница 2: ...ons should always be followed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store...

Страница 3: ...the equipment especially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gas...

Страница 4: ...s such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sens...

Страница 5: ...irator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 7 Have the equipment s...

Страница 6: ...W 30 above 32 F 5W 30 at 32 F or below Capacity 6 Quart 6L Run Time 50 load 10 hr Operational Volume 72 dB Available accessories Wheel kit sold separately Item 69675 The emission control system for th...

Страница 7: ...ipment only to the AC Receptacle that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protect...

Страница 8: ...tem 68531 sold separately can be used with this generator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do...

Страница 9: ...tarting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before Starting the Generator Engine Before starting the engine a Follow the Set Up...

Страница 10: ...ow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts N...

Страница 11: ...require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive...

Страница 12: ...d To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated...

Страница 13: ...Stopping the Engine in an Emergency To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engi...

Страница 14: ...ualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment ope...

Страница 15: ...crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around it Remove the Dipstick by threading it counter...

Страница 16: ...engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL WARNING To prevent serious injury from fire Drain the fuel tank in a well ventilated area away from ign...

Страница 17: ...e to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter Ignition spark Related 1 S...

Страница 18: ...e to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel...

Страница 19: ...lange 2 55 Plate Comp Side 1 56 Bolt Flange 1 57 Clip Harness 1 58 Coil Assy Ignition 1 59 Bolt Flange 2 60 Flywheel Comp 1 61 Fan Cooling 1 62 Pulley Starter 1 63 Nut Flange 1 64 Recoil Starter Comp...

Страница 20: ...Bottom 2 110 Rubber Right Bottom 2 111 Nut Flange 8 Part Description Qty 112 Bolt Flange 4 113 Rubber Shock Absorber 4 114 Nut Flange 4 115 Plate Guard 1 116 Cable Assy Earth 1 117 Case Control Panel...

Страница 21: ...Page 21 For Pump technical questions please call 1 800 444 3353 For Engine technical questions please call 1 800 520 0882 Item 69675 69676 Safety Operation Maintenance Setup Assembly Diagram...

Страница 22: ...Page 22 For Pump technical questions please call 1 800 444 3353 For Engine technical questions please call 1 800 520 0882 Item 69675 69676 Safety Operation Maintenance Setup Assembly Diagram cont...

Страница 23: ...tem on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as the ca...

Страница 24: ...arts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommend...