Predator 61725 Скачать руководство пользователя страница 5

Page 5

For technical questions, please call 1-888-866-5797.

ITEM 61725 

        

SAFETY

Op

ERA

TION

M

AINTENANCE

SETU

p

Operating precautions

1. 

CARBON MONOXIDE HAZARD 

Using a generator indoors  

CAN KILL YOU IN MINUTES. 

Generator exhaust contains 

carbon monoxide.  This is a poison 

you cannot see or smell. 

NEVER use inside a home or garage,  

EVEN IF doors and windows are open. 

Only use OUTSIDE and far away from windows, 

doors, and vents.

2.  Never use a generator indoors, including in 

garages, basements, crawl spaces and sheds. 

Opening doors and windows or using fans will NOT 

prevent carbon monoxide build up in the home.

3.  When using generators, keep them outdoors 

and far away from open doors, windows, 

and vents to avoid toxic levels of carbon 

monoxide from building up indoors.

4.  If you start to feel sick, dizzy, or weak while 

using a generator, get to fresh air right away. 

The carbon monoxide from generators can 

quickly lead to full incapacitation and death.

5.  Keep children away from the equipment, 

especially while it is operating. 

6.  Keep all spectators at least six feet 

from the Engine during operation.

7.  Fire Hazard! Do not fill fuel tank while engine is 

running. Do not operate if gasoline has been spilled. 

Clean spilled gasoline before starting engine. 

Do not operate near pilot light or open flame.

8.  Do not touch engine during use. 

Let engine cool down after use. 

9.  Never store fuel or other flammable 

materials near the engine.

10. If the plugged in product operates abnormally 

or unusually slow, immediately stop using the 

generator as a power source.  Read and adhere 

to the instruction manual of the product to be 

powered to make sure that it can be safely and 

efficiently powered by a portable generator.

11.  Before connecting an appliance or power cord 

to the generator:  Make sure that it is in good 

working order.  Faulty appliances or power cords 

can create a potential for electrical shock.

12. Do not exceed the maximum power rating of the 

generator. Make sure that the total electrical rating 

of the all of the tools or appliances plugged into 

the generator at the same time does not exceed 

that of the generator. Check that the startup surge 

will not be beyond the limit of the Generator. 

13. Avoid substantially overloading which will trip 

the circuit breaker. Slightly overloading the 

generator may not trip the circuit breaker, 

but will lead to premature generator failure.

14. Do not attempt to connect or disconnect 

load connections while standing in water, 

or on wet or soggy ground.

15. Do not touch electrically energized parts of 

the Generator and interconnecting cables 

or conductors with any part of the body, or 

with any non-insulated conductive object.

16. Connect the Generator only to a load that is 

compatible with the electrical characteristics 

and rated capacities of the Generator.

17. Insulate all connections and disconnected wires.
18. Guard against electric shock.  Prevent body contact 

with grounded surfaces such as pipes, 

radiators, ranges, and refrigerators.

19. Only use a suitable means of transport and 

lifting devices with sufficient weight bearing 

capacity when transporting the generator.

20. Secure the generator on transport vehicles to 

prevent it from rolling, slipping, and tilting.

21. Industrial applications must follow 

OSHA requirements.

22. Do not leave the generator unattended when it is 

running.  Turn off the generator (and remove safety 

keys, if available) before leaving the work area.

23. The generator can produce high noise levels.  

Prolonged exposure to noise levels 

above 85 dBA is hazardous to hearing. 

Wear ear protection when operating the  generator 

or when working nearby while it is operating.

24. Wear ANSI-approved safety glasses 

and hearing protection during use.

25. People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 

close proximity to a heart pacemaker could cause 

pacemaker interference or pacemaker failure.  

Caution is necessary when near the 

engine’s magneto or recoil starter.

Содержание 61725

Страница 1: ...or exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and v...

Страница 2: ...air cooled Fuel Type 87 octane unleaded gasoline Capacity 7 Gallon Engine Oil Type SAE 10W 30 above 32 F 5W30 at 32 F or below SJ class oil Capacity 2 Quart Run Time 50 Load with full tank 7 5 hr Sou...

Страница 3: ...y Wear ANSI approved safety goggles with side shields Read the manual before set up and or use WARNING marking concerning Risk of Hearing Loss Wear hearing protection Symbol Property or Statement WARN...

Страница 4: ...nd other regulations where applicable 6 Connections for standby power to a building electrical system must be made by a qualified electrician The connection must isolate the generator power from utili...

Страница 5: ...shock 12 Do not exceed the maximum power rating of the generator Make sure that the total electrical rating of the all of the tools or appliances plugged into the generator at the same time does not e...

Страница 6: ...nd in the manner intended for the particular type of equipment taking into account the working conditions and the work to be performed Use of the equipment for operations different from those intended...

Страница 7: ...goggles heavy duty work gloves and dust mask respirator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freig...

Страница 8: ...SH TO RESET 30A AC BREAKER PUSH TO RESET 30A AC BREAKERS PUSH TO RESET 46A AC BREAKER AC 120V AC 120V 20A MAX 20A MAX 30A MAX 30A MAX AC 120V AC 120 240V AC 120 240V 46A MAX PUSH TO RESET DC 12V 8 3A...

Страница 9: ...7 ITEM 61725 Safety Operation Maintenance Setup Control Panel Battery sold separately Handle Spark Plug 1 of 2 Fuel Cap Figure B Generator Front Lifting Bracket Fuel Valve Muffler Oil Fill Plug Dipsti...

Страница 10: ...e ensured by installing an altitude kit at altitudes higher than 3000 ft above sea level At elevations above 8000 ft the engine may experience decreased performance even with the proper main jet Opera...

Страница 11: ...G 7 Detach the top of the Fuel Filter Clip 147 from the Air Cleaner Base 142g Intake Cover Bolts 143 Air Cleaner Base Bolts 146 Fuel Filter Clip 147 Air Cleaner Base 142g Figure G Remove Bolts and Cl...

Страница 12: ...h Fuel Hose 13 Locate the Throttle Rod 174 connection on the left side of the carburetor See Figure J Throttle Rod 174 Throttle Rod Spring 175 Throttle Rod Clip 139 Figure J Disconnect Throttle Rod 14...

Страница 13: ...e the Fuel Pump Bracket was the Solenoid Valve 138 is connected Note the location of the green wire and green dot on the connector Unplug the connector See Figure O Solenoid wire connector Note locati...

Страница 14: ...rburetor Bowl 137c See Figure Q Carburetor Bowl Bolt 137b Carburetor Bowl Bolt 137b Carburetor Bowl 137c Carburetor Bowl Bolt 137b Carburetor Bowl Bolt 137b Figure Q Carburetor Bowl Bolts 26 Use a car...

Страница 15: ...lip under left side of Air Cleaner Base Install the Intake Cover and Intake Screen using the Intake Cover Bolts 6 8 12 Place the Paper Air Filter Foam Air Filter Air Cleaner Spacer and Air Cleaner Top...

Страница 16: ...opped and is level 2 Close the Fuel Valve 3 On the back of the Generator pull the Dipstick out and wipe its end off with a clean lint free rag 4 Reinsert the Dipstick fully and remove it to check the...

Страница 17: ...ning more than 10 ethanol E10 Do not use E85 ethanol Add fuel stabilizer to the gasoline or the Warranty is VOID Note Do not use gasoline that has been stored in a metal fuel container or a dirty fuel...

Страница 18: ...or several seconds Then if the Choke lever is in the CHOKE position move the Choke Lever very slowly to its RUN position Note Moving the Choke Lever too fast could stall the engine IMPORTANT Allow the...

Страница 19: ...only Check nameplate wattages on all loads before connecting to Generator This Unit Can Power Any One of the Following Items Running Watts Start up Watts 1 4 HP Air Compressor 600 900 1 6 HP Motor 50...

Страница 20: ...t instead Cleaning Maintenance and Lubrication Schedule Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems i...

Страница 21: ...ngine while the smell of fuel hangs in the air Engine Oil Change CAUTION Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil 1 Make sure the engine is stop...

Страница 22: ...ench remove the spark plugs 3 Inspect the spark plugs If the electrode is oily clean it using a clean dry rag If the electrode has deposits on it polish it using emery paper If the white insulator is...

Страница 23: ...lean out area around spark plug Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole c Replace spark plug but leave spark plug cap disconnected d Pull Starter...

Страница 24: ...ve spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not conn...

Страница 25: ...g equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane unle...

Страница 26: ...plain the emissions control system warranty on your 2014 2015 Small Off Road Engine herein engine Within the United States new off road spark ignition engines certified for model year 2014 2015 must m...

Страница 27: ...not scheduled for replacement as required maintenance or are scheduled only for regular inspection to the effect of repair or replace as necessary are warranted for the warranty period Any warranted p...

Страница 28: ...63 Pump Asm Oil 1 64 Cover Oil Pump 1 65 Spring Pressure Relief Valve 1 66 Ball Steel 1 67 Strainer Oil 1 68 Gear Asm Governor 1 Part Description Qty 69 Oil Dipstick 1 70 Gasket Oil Pump 1 71 Cranksha...

Страница 29: ...Combination 1 201 Bolt 16 202 Nut 16 203 Nut 4 204 Washer Flat 4 205 Cushion Engine Frame 4 206 Bolt 8 207 Bolt 4 Part Description Qty 208 Lifting Handle 1 209 Screw 1 210 Support Engine Frame Shock A...

Страница 30: ...6 205 206 205 206 206 206 205 206 206 205 215 218 213 213 216 216 217 217 211 211 210 211 211 212 202 202 201 203 203 203 201 201 208 207 209 207 207 207 221 200 206 214 204 204 221 222 222 211 211 21...

Страница 31: ...0 51 51 26 25 27 32 43 28 30 32 33 42 31 30 29 31 36 35 36 42 36 36 34 37 38 38 38 39 41 39 40 42 42 48 34 42 46 42 44 47 45 45 53 53 52 52 52 52 52 52 52 57 58 59 55 54 55 56 64 61 63 65 66 67 60 62...

Страница 32: ...3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 1 888 866 5797...