2
Operation Verification
This section provides a method of verifying the P82 operation. Check the P82 operation at the
end of a maintenance procedure and when it is necessary to ensure that the console is oper-
ating properly.
"Operation Verification Procedure" below
"Operation Verification Checklist" below
Operation Verification Procedure
Perform these tests to verify operation of the unit.
1. Plug the power cord into the wall outlet and switch the power switch to the "ON" pos-
ition.
Operation Verification Checklist
Use this checklist to track that the verification procedure tests were successfully completed
and that the [[[Undefined variable TRM10Base.EqptType]]] operation has been verified:
Check, record, and then clear any errors in the error log.
Verify that all LEDs function properly during the Hardware Validation tests.
Verify that all keys on the keypad function properly during the Hardware Val-
idation tests.
Verify that the heart rate functions normally and displays a valid heart rate.
Verify the running belt drive system functions properly throughout the minimum
to maximum range of control. All drive system components (deck, belts, rollers,
IFT) are free of excessive noise, vibrations, or smells.
Verify the Incline A/D value is approximately 6000+/-500 at 0% incline, the
incline operates within the complete range of the lift when the UP or DOWN
keys are pressed and is free of excessive noise or vibrations.
Verify the STOP button stops the running belt from moving.
Verify that pulling the ESTOP cord stops the running belt from moving.
Check for any new error codes that may have been logged in the error log during
operation verification of the treadmill.
.
P82 Console
19
2 Operation Verification
Operation Verification Procedure