Procedure 6.6 - Troubleshooting the Eddy Current System
Note:
If the control circuit does not see an output from the speed sensor, it removes power from the
eddy current system. Therefore, when it is necessary to check the resistance or take voltage
measurements in the eddy current system it will be necessary to slowly turn the flywheels to
ensure that the power time out has not occurred.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know
1.
There are three typical symptoms concerning the eddy current system. No resistance
(pedaling resistance), no resistance shortly after power up and incorrect resistance. If the
problem is no resistance, continue with step 2. If the problem is no resistance shortly after
power up, test the speed sensor per Procedure 6.4. If the problem is incorrect resistance,
skip to step 7.
2.
Set the on/off switch in the “on” position, enter the manual program and set the resistance at
level 10. Using a DC voltmeter, check the voltage across the magnet. The voltage should
measure approximately 29.5 Vdc. If the voltage is missing or significantly low, skip to step 4.
If the voltage is correct, continue with step 3.
3.
Set the on/off switch in the “off” position. Check the magnet wiring per Diagram 8.1. If any of
the magnet wiring is reversed or incorrect the resistance will be affected. If you have
performed all of the above tests and there is still no resistance, call Precor Technical
Support.
4.
Set the on/off switch in the “off” position. Using an ohmmeter, measure between the M- and
M+ terminals of the lower PCA. The measurement should be approximately 90
Ω
to 110
Ω.
If
the measurement is open (
∞
), check the connections at both magnets and the lower PCA.
5.
If all of the wiring connections are good and there is still no resistance, there are three parts
that could cause the problem. There are not any good tests to check these parts other than
substituting a known good part. They are lower PCA, ribbon cable and upper PCA. Replace
only one part at a time. If the new part does not correct the problem replace the original part.
6.
If you have performed all of the above tests and there is still no resistance, call Precor
Technical Support.
7.
If the resistance is greater than normal, the cause could be mechanical rather than
electrical. Check all moving parts in the drive section and stairarms for worn parts that could
be “binding”. Replace the appropriate parts.
8.
Set the on/off switch in the “on” position, enter the manual program and set the resistance at
level 10. Using a DC voltmeter, check the voltage across the magnet. The voltage should
measure approximately 29.5 Vdc.
Содержание C546
Страница 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Страница 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Страница 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Страница 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Страница 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Страница 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...