![Precor C534i Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/precor/c534i/c534i_service-manual_1594682009.webp)
C534i Elliptical Fitness Crosstrainer
Page 9
Procedure 2.2 - Accessing the Information Display
Procedure
1.
This is a self powered unit, to power the EFX it must be pedaled or the external power
supply must be equipped.
2.
With the
PRECOR
EFX
banner displayed, press keys
RESET,6,5
, sequentially.
Diagnostics Test
Odometer
Hour meter
U-Boot Software version
U-Base Software version
Lower software version
Metrics Board SW Part Number
Serial Number
Usage Log
Error log
4.
The test name
DIAGS - INFORMATION DISPLAY
will scroll once across the display. Press
the
OK
key to proceed to odometer or use the
S
,
T
keys to proceed a different display.
4.
The display name “
ODOMETER”
will be displayed, press the
OK
key, the odometer value
will be displayed, as total strides accumulated.
5.
Press the
CANCEL
key to proceed to the hour meter display.
6.
The display name “
HOUR METER”
will be displayed, press the
OK
key, the hour meter will
be displayed, as the total number of hours of use. Fractional parts of an hour are stored
internally, the display will be truncated to the nearest full hour.
7.
Press the
CANCEL
key to proceed to the U-Boot software version display.
8.
The display name “
U-BOOT SW”
will be displayed, press the
OK
key, the U-Boot software
part number will be displayed.
9.
Press the
CANCEL
key to proceed to the U-Base software version display.
10. The display name “
U-BASE SW”
will be displayed, press the
OK
key, the U-Base software
part number will be displayed.
11. Press the
CANCEL
key to proceed to the lower software version display.
12. The display name “
LOWER SW”
will be displayed, press the
OK
key, the lower software
part number will be displayed.
13. Press the
CANCEL
key to proceed to the metrics board software version display.