6.2 Installation (integration into the machine)
6 - 58
© Precitec GmbH & Co. KG • EN 09/2019
6.2.3.2
Grounding the laser head
If not earthed correctly, sensor system malfunctions may occur and the
machine may be damaged by moving parts
(jerky guidance of the laser head, vibra-
tions)
!
Fig. 6-7
Installation: Laser head - grounding
(3D version)
Gewindebohrungen
Make sure the system and the laser head are earthed according to regulations.
The laser head has four threaded holes M6
(14 mm deep)
at back. These must
be connected to protective earth
(PE)
.
Содержание Lasermatic LightCutter
Страница 4: ...Notes LightCutter iv Precitec GmbH Co KG EN 09 2019 D 159195 Notes...
Страница 81: ...Notes Precitec GmbH Co KG...