NSP-550-EC Component Layout

NOTE 

COMPONENT LAYOUT OF  

RV-550-EC IS IDENTICAL TO 

NSP-550-EC EXCEPT FOR FLUING 

ORIENTATION WHICH FLUES 

THROUGH TOP/FRONT RATHER 

THAN BOTTOM.

1.

 

Hall Sensor Flow Meter

2.

 

Power Vent

3.

 

Fluing Vacuum Switch

4.

 

Combination Gas Valve

5.

 

Igniter / Proofing Probe

6.

 

Manifold and Burner

7.

 

Finned Tube Heat Exchanger

8.

 

Flue Hood

9.

 

Flue Pipe

10.

 

T-In Thermistor

11.

 

T-Mid Thermistor

12.

 

T-Out Thermistor

13.

 

165°F ECO

14.

 

100 PSI Pressure Relief Valve

15.

 

Gas Modulation Valve

NOT PICTURED

16.

 

12 VDC Relay

17.

 

Control Board

18. 

 

Direct Spark Ignition Board

Содержание RV-550 NSP-EC

Страница 1: ...l codes the Standard on Recreational Vehicles NFPA1192 and or CAN CSA Z240 RV CLEARANCE Requirements SIdes top and bottom 0 Back Enough to make connections but no less than 2 5 Front Enough to remote...

Страница 2: ...e unit and drill the 4 3 8 mounting holes in the floor 5 Apply a rubber gasket or sealant around the combustion air hole on the bottom of the unit and mount unit in place assuring the seal is in compl...

Страница 3: ...odes or in the absence of local codes Standard on Recreational Vehicles ANSI A119 2 or CAN CSA Z240RV CAUTION ELECTRICAL DAMAGE Label all wires prior to disconnection when servicing controls Wiring er...

Страница 4: ...water This cold water has to be purged from the line each time the shower head is turned back on Tests have shown that this will not save water and sometimes uses more water than leaving the shower r...

Страница 5: ...or Flow Meter 2 Power Vent 3 Fluing Vacuum Switch 4 Combination Gas Valve 5 Igniter Proofing Probe 6 Manifold and Burner 7 Finned Tube Heat Exchanger 8 Flue Hood 9 Flue Pipe 10 T In Thermistor 11 T Mi...

Страница 6: ...ctions is in the off position An open valve can also permit water to bypass heater causing it not to fire There Is No Ignition When Water Is On Power vent is running 1 Be sure the gas valve at the tan...

Страница 7: ...he date of purchase PrecisionTemp will replace the complete water heater if the heat exchanger leaks due to corrosion This warranty includes reasonable labor charges required to replace the complete w...