3
FIGURE 3
HOSE CONNECTIONS and ROUTING
New hoses should be run so they follow the approximate routing of the old hoses. This keeps crops
and debris from dragging on the hoses during operation. Run the new hoses from the valve upward
using supplied 90-degree elbow fittings and route the hoses underneath the cab toward the steering
orbital. (Shown in Figures 2, 3 and 4)
Valve control cable
is routed into the
cab through the
electrical connec-
tion bulk head.
Hoses from the valve
are run upwards from
the valve and under-
neath the cab.
Cables for the steering
position sensor are
secured to existing
hoses on the right side
of the machine.
All tees are placed on the steering orbital.
Existing tank, boom lock, right and left steer-
ing lines are attached to one side of their
respective tees.
FIGURE 4