General Dimensions
General Specifications
Air Supply
Standard Features
Important Safety Advice 
Boiler Stoves: Specific Safety Issues
Health and Safety
Building Control and Hetas
Installation Regulations
UK Smoke Control Areas
Buildings Insurance
Packing List
Assembling the Stove
Accessing the Flueway
Removing the Baffle Plate
Recommended Fuels
Prohibited Fuels
Understanding Fuel Types
Controlling The Combustion Air
Burning Wood Logs
Lighting a Wood Fire
Burning Mineral Fuels
Extended Burning
Removing Ash
Installation Check-list
Appliance installation Guidelines
System installation Guidelines
Basic System Essentials
Basic System Diagram
Commissioning
Important: First Fires
Condensation
System Balance
Trouble-shooting
Routine Checks
Regular Maintenance
Standing Down
The Hi-Flame Warranty
Precision Spare Parts and Consumables
Annual Service
Service Record
System Notes and Settings

2

This instruction manual is also used for a number of 
other boiler stove models in the Hi-Flame product 
range and therefore some of the stove photographs 
and diagrams used, which are used for guidance 
purposes only, may differ slightly from your new  
Precision Boiler stove. However, the principles 
illustrated here remain the same.

 

Hi-Flame Fireplace (UK) Limited

INTRODUCTION

Thank-you for purchasing the Precision III 
Boiler stove. We are confident that it will 
warm your home even on the coldest winter 
days and provide you with many years of  
pleasurable heat. 
Before you install or operate your boiler 
stove, in the interests of safety, please read 
this booklet which contains important safety 
advice as well as instructions which will help 
you make the most of your new boiler stove.
All users of this stove should be aware of the 
contents of this handbook. If other people 
are going to operate the stove then please 
keep this booklet handy so that it can always 
be quickly referred to. Never let anyone use 
the stove who is unfamiliar with its correct 
operation.

VERY IMPORTANT

Under no circumstances operate this boiler stove 
without it being connected to a hot water  
system or without water in the boiler. When  
filling the system always use a proprietary  
chemical water treatment to protect the boiler 
from corrosion and the build-up of solid  
deposits. 
If you are installing this stove in a UK Smoke 
Control Area the Precision Boiler stove can only 
be fuelled with approved smokeless fuels – it 
will be illegal to burn wood or any other non-
approved fuels in it

.

Even if you have installed or operated stoves 
before, remember manufacturer’s requirements 
can vary and can also change with updates to 
building regulations – therefore, please read this 
manual before you install or operate your stove.

Содержание Horse Flame HF910-B

Страница 1: ...hese instructions to ensure safe and ef cient operation You will need to refer to the serial number of your stove should you ever need to make a claim under the Horse Flame Warranty You will nd the se...

Страница 2: ...principles illustrated here remain the same Hi Flame Fireplace UK Limited INTRODUCTION Thank you for purchasing the Precision III Boiler stove We are con dent that it will warm your home even on the c...

Страница 3: ...3 GENERAL DIMENSIONS All sizes in mm Important Take all critical pipework measurements from the stove on site...

Страница 4: ...riod Nominal Heat Output To Space 5 7 kW To Water 9 4 kW TOTAL 15 1 kW Ef ciency net 74 9 Mean CO Emission at 13 0 43 Mean Flue Gas Temperature 346 C Flue Gas Mass Flow 10 6 g s Mineral Fuels Ancit Co...

Страница 5: ...of the stove when it is in use Check and clean the stove s ue way and the top of the baf e plate regularly to help avoid potential blockages Clean your chimney regularly BOILER STOVE SYSTEMS SPECIFIC...

Страница 6: ...ody recognised by the Government to approve solid fuel domestic heating appliances and the registration of competent installers HETAS registered installers in England and Wales can self certi cate the...

Страница 7: ...l authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of Smoke Control Areas and you can contact them for details of Clean Air Act requirements Even...

Страница 8: ...way to avoid potential soot build up and blockages Once you know how to do this it is a very easy operation See below Flue Outlet The HF910 B stove has a 150mm 6 ue outlet on the top of the stove ther...

Страница 9: ...access to the top of the boiler as well as the ue way First remove the stove lid by undoing the two bolts towards the rear of the ue pipe Use the correct sized Phillips crosshead screwdriver The heav...

Страница 10: ...t smoky smells both inside and sometimes outside the house In the event of a problem with your stove always check your choice of fuel rst Manufactured or nished wood products such as plywood and chipb...

Страница 11: ...of combustion air that wood and mineral fuels need Your new stove can burn very well or very poorly depending on how you light the re how you refuel the re and of course the type and quality of the f...

Страница 12: ...ap of approximately 25mm 1 between both ends of the logs and the boiler sides Log ends placed against the boiler sides restrict combustion and can create unwanted cold spots in both the log and the wa...

Страница 13: ...ckly set Wood burns best if the ames have other wood to play off For example a single dense piece of wood or log will not burn as well as 2 or 3 smaller logs of equivalent mass The more contact the wo...

Страница 14: ...s 1 Boiler stoves operate at a much lower temperature than non boiler stoves and consequently the potential to create soot or creosote build up in the ue system is also much greater especially when op...

Страница 15: ...re the heat into the room To do this ensure the Primary and Secondary Air is fully closed Then simply control the ame pattern and burn rate with the Thermostat Control However you may still need to un...

Страница 16: ...lding regulations it is also a requirement of your Warranty that the stove is installed by a competent person such as a Hetas or INFO registered installer who will be fully aware of any building and s...

Страница 17: ...orting the weight of the stove when loaded and boiler with water add ap prox 15kg along with any attached exible ue liner which may bear down on the stove This hearth must conform to local building re...

Страница 18: ...nd ef ciency Your existing chimney could leak smoke fumes and potentially dangerous invisible carbon monoxide into other parts of the building Condensation or creosote tar often associated with burnin...

Страница 19: ...tem diagram shown overleaf should be used for general guidance purposes only and is included here to demonstrate basic system principles Combined with the at a glance list below this should provide yo...

Страница 20: ...20...

Страница 21: ...cally be switched on This safety precaution will ensure that the gravity circuit does not overheat A low limit thermostat set at 45 C should be tted to the gravity return pipework and connected to the...

Страница 22: ...5 22 7 Legal Requirements Explain the householder s legal requirement to use an approved reguard whenever children or the elderly and the in rm are likely to be in the vicinity of the stove If the ins...

Страница 23: ...w it is extremely important that the radiators are balanced to ensure an ef cient distribution of heat as well as an even heat balance from one radiator to the next The idea is to reduce the ow to the...

Страница 24: ...ould also indicate that the chimney or ue itself also needs cleaning Causes Inadequate supply of combustion air Check that any permanent air vent tted to supply the extra combustion air required for t...

Страница 25: ...m because the Airwash does not get hot enough and some blackening of the glass should be considered a because draught stabilisers limit the exit of ue gases from the stove they should only ever be spe...

Страница 26: ...ter then it is more than likely to be a problem with the system The simplest way to determine this is if possible to check that the top water pipe from the stove is hot and that the lower pipe is cool...

Страница 27: ...such staining to build up as it will become more dif cult to remove after each ring When used regularly a proprietary scratch resistant stove glass cleaning gel or spray which can be supplied by your...

Страница 28: ...led joint Also replace the middle horizontal rope that seals the ash pan chamber from the re chamber to maintain a good Primary Air ow The recommended rope seal diameter is 12mm Air Supply Controls Th...

Страница 29: ...ler parts and 1 year labour The warranty does not cover parts deemed to be consumables These include paint rebricks re grates vermiculite panels smoke de ection plates baf e plates gaskets rope seals...

Страница 30: ...k all parts for wear or damage and replace as necessary Re t internal parts and ueway access lid Stove Glass Check the glass for chips or cracks and the glass seal condition and replace if necessary T...

Страница 31: ...ES AND SETTINGS For future reference include a basic drawing of the system and notes on the circulation pump and system thermostat settings etc as well as their location and the location of the system...

Страница 32: ...pel Cheshire CW4 8AF United Kingdom Horse Flame Precision Multi Fuel Stoves 2013 All rights reserved Booklet contents may not be copied in whole or in part without the prior written permission of the...