Mode 4: 

12h Cycle, 1h periods

 

Once set or powering on the PDU whilst in this mode, the PDU will cycle through each of the controlled 

 

sockets sequentially providing power for a period of 1 hour. Once the 4th socket has completed its 1 

 

hour period all controlled sockets will remain unpowered for the remainder of the 12 hour cycle 

 

(8 hours).

Mode 5: 

12h Cycle, 2h period

 

This mode behaves the same as mode 4, however this mode powers each of the controlled socket for a 

 

period of 2 hours therefore leaving the controlled sockets unpowered for the remainder of the 12 hour 

 

cycle (4 hours).

Содержание 800-410058

Страница 1: ...Controlled Laptop Charger Instruction Manual Telephone 02 6299 3477 Email sales 3p australia com au PO Box 6321 Queanbeyan East NSW 2620 Australia www 3p australia com au ...

Страница 2: ...Display Disabled All controlled sockets are off with power only to the constantly powered sockets Mode LED flashes once every 4 seconds to indicate unit power Staged On All sockets are enabled after staged powering of controlled sockets 1 4 with approximately a 1 5 second delay between sockets Mode LED is constant Constant Cycle The controlled sockets are cycled continuously in order from socket 1...

Страница 3: ...ontrolled socket by up to 91 7 of that of a constantly powered socket Installation The installation procedure for the Controlled Laptop Charger is as follows 1 If rack mounting is desired the Controlled Laptop Charger may be screwed directly onto 19 mounting rails using two M6 screws and cages nuts on each side Two mounting configurations are possible for the 1 5 RU power board Use either the top ...

Страница 4: ...to Stage On or powering on the PDU whilst in this mode the controlled sockets will power on in series with an approximate 1 5 second delay Once all sockets are on they will remain powered Mode 3 Constant Cycle 1 Hour period Once set or powering on the PDU whilst in this mode the PDU will cycle through each of the controlled sockets sequentially providing power for a period of 1 hour Once the 4th s...

Страница 5: ... the controlled sockets sequentially providing power for a period of 1 hour Once the 4th socket has completed its 1 hour period all controlled sockets will remain unpowered for the remainder of the 12 hour cycle 8 hours Mode 5 12h Cycle 2h period This mode behaves the same as mode 4 however this mode powers each of the controlled socket for a period of 2 hours therefore leaving the controlled sock...

Отзывы: